/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --tempDir=temp_AixLib_AixLib_Fluid_DistrictHeatingCooling_Supplies_Examples_DHCSupplyHeaterCoolerStorage_fmu --startTime=0 --stopTime=172800 --timeout=50 --tolerance=1e-05 AixLib_AixLib_Fluid_DistrictHeatingCooling_Supplies_Examples_DHCSupplyHeaterCoolerStorage.fmu LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 2.1.0/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:391:3-398:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((substation1.pumHeaPri.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning in DHCSupplyHeaterCoolerStorage.substation1.pumHeaPri: Mover is flow or pressure controlled and uses default pressure curve. | | | | This leads to an approximate power consumption. | | | | Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 2.1.0/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:391:3-398:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((substation1.pumCoo.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning in DHCSupplyHeaterCoolerStorage.substation1.pumCoo: Mover is flow or pressure controlled and uses default pressure curve. | | | | This leads to an approximate power consumption. | | | | Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 2.1.0/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:391:3-398:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((substation2.pumHeaPri.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning in DHCSupplyHeaterCoolerStorage.substation2.pumHeaPri: Mover is flow or pressure controlled and uses default pressure curve. | | | | This leads to an approximate power consumption. | | | | Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 2.1.0/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:391:3-398:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((substation2.pumCoo.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning in DHCSupplyHeaterCoolerStorage.substation2.pumCoo: Mover is flow or pressure controlled and uses default pressure curve. | | | | This leads to an approximate power consumption. | | | | Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning." LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 2.1.0/Fluid/Movers/FlowControlled_m_flow.mo:93:3-98:58:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | (((-substation1.pumHeaPri.dp) <= 4e4)) --> "In DHCSupplyHeaterCoolerStorage.substation1.pumHeaPri: Model operates with head -dp = 157667 Pa, | | | | exceeding the pressure allowed by the parameter DHCSupplyHeaterCoolerStorage.substation1.pumHeaPri.dpMax. | | | | This can happen if the model forces a high mass flow rate through a closed actuator, | | | | or if the performance record is unreasonable. Please verify your model, and | | | | consider using one of the other pump or fan models." error: [fmi2logger] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/AixLib_AixLib.Fluid.DistrictHeatingCooling.Supplies.Examples.DHCSupplyHeaterCoolerStorage/temp_AixLib_AixLib_Fluid_DistrictHeatingCooling_Supplies_Examples_DHCSupplyHeaterCoolerStorage_fmu/model-os761bqs/temp/0001_AixLib_AixLib_Fluid_DistrictHeatingCooling_Supplies_Examples_DHCSupplyHeaterCoolerStorage (logFmi2Call): fmi2EnterInitializationMode: terminated by an assertion. error: [initialize] fmi2_import_exit_initialization_mode failed for FMU "model.root.AixLib_AixLib_Fluid_DistrictHeatingCooling_Supplies_Examples_DHCSupplyHeaterCoolerStorage" error: [initialize] Initialization of system "model.root" failed error: [simulate] Model "model" is in wrong model state info: 0 warnings info: 4 errors