/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --tempDir=temp_AixLib_AixLib_Airflow_FacadeVentilationUnit_Examples_FacadeVentilationUnit_fmu --startTime=0 --stopTime=86400 --stepSize=34.56 --timeout=50 --tolerance=1e-06 AixLib_AixLib_Airflow_FacadeVentilationUnit_Examples_FacadeVentilationUnit.fmu warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input warning: Failed to save settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input info: Set temp directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/AixLib_AixLib.Airflow.FacadeVentilationUnit.Examples.FacadeVentilationUnit" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/AixLib_AixLib.Airflow.FacadeVentilationUnit.Examples.FacadeVentilationUnit" info: New model "model" with corresponding temp directory "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/AixLib_AixLib.Airflow.FacadeVentilationUnit.Examples.FacadeVentilationUnit/model-ny5mf1qv" info: *** FMU Simulation Info *** - model: model (model exchange) - path: AixLib_AixLib_Airflow_FacadeVentilationUnit_Examples_FacadeVentilationUnit.fmu - startTime: 0.000000 - stopTime: 86400.000000 - tolerance: 0.000001 - stepSize: 34.560000 LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 2.1.0/Fluid/Movers/FlowControlled_m_flow.mo:93:3-98:58:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | (((-FVU.fanSupplyAir.fan.dp) <= 2000.0)) --> "In FacadeVentilationUnit.FVU.fanSupplyAir.fan: Model operates with head -dp = 100800 Pa, | | | | exceeding the pressure allowed by the parameter FacadeVentilationUnit.FVU.fanSupplyAir.fan.dpMax. | | | | This can happen if the model forces a high mass flow rate through a closed actuator, | | | | or if the performance record is unreasonable. Please verify your model, and | | | | consider using one of the other pump or fan models." error: [fmi2logger] [fmi2Error] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/AixLib_AixLib.Airflow.FacadeVentilationUnit.Examples.FacadeVentilationUnit/model-ny5mf1qv/temp/0001_AixLib_AixLib_Airflow_FacadeVentilationUnit_Examples_FacadeVentilationUnit/logFmi2Call: fmi2EnterInitializationMode: terminated by an assertion. error: [initialize] fmi2_import_exit_initialization_mode failed for FMU "model.root.AixLib_AixLib_Airflow_FacadeVentilationUnit_Examples_FacadeVentilationUnit" error: [initialize] Initialization of system "model.root" failed error: [SimulateSingleFMU] oms_initialize failed info: 2 warnings info: 4 errors