Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr ThermoSysPro_ThermoSysPro.Fluid.Examples.Book.SimpleExamples.HeatExchanger.DynamicWaterHeater.Islanding.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/package.mo", uses=false) Using package ThermoSysPro with version 4.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/package.mo) Running command: "" <> buildModelFMU(ThermoSysPro.Fluid.Examples.Book.SimpleExamples.HeatExchanger.DynamicWaterHeater.Islanding,fileNamePrefix="ThermoSysPro_ThermoSysPro_Fluid_Examples_Book_SimpleExamples_HeatExchanger_DynamicWaterHeater_Islanding",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(ThermoSysPro.Fluid.Examples.Book.SimpleExamples.HeatExchanger.DynamicWaterHeater.Islanding,fileNamePrefix="ThermoSysPro_ThermoSysPro_Fluid_Examples_Book_SimpleExamples_HeatExchanger_DynamicWaterHeater_Islanding",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/package.mo): time 0.9048/0.9048, allocations: 150.9 MB / 166.5 MB, free: 14.39 MB / 142.1 MB Notification: Performance of FrontEnd - loaded program: time 0.0007112/0.0007113, allocations: 15.41 kB / 236.6 MB, free: 2.035 MB / 190.1 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.08208/0.08281, allocations: 31.34 MB / 267.9 MB, free: 7.602 MB / 222.1 MB Notification: Automatically loaded package Complex 4.0.0 due to uses annotation from Modelica. Notification: Automatically loaded package ModelicaServices 4.0.0 due to uses annotation from Modelica. Notification: Automatically loaded package Modelica 4.0.0 due to usage. Notification: Performance of NFInst.instantiate(ThermoSysPro.Fluid.Examples.Book.SimpleExamples.HeatExchanger.DynamicWaterHeater.Islanding): time 1.753/1.836, allocations: 309.8 MB / 0.5642 GB, free: 14.47 MB / 462.1 MB Notification: Performance of NFInst.instExpressions: time 0.5834/2.419, allocations: 205.1 MB / 0.7645 GB, free: 1.434 MB / 0.5919 GB Notification: Performance of NFInst.updateImplicitVariability: time 0.004289/2.424, allocations: 83.69 kB / 0.7646 GB, free: 1.434 MB / 0.5919 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/BoundaryConditions/SourceP.mo:58:3-59:65:writable] Warning: Connector C is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/BoundaryConditions/SinkP.mo:46:3-47:67:writable] Warning: Connector C is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/ControlValve.mo:44:3-45:68:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/ControlValve.mo:46:3-47:66:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/TwoPhaseCavity.mo:182:3-184:57:writable] Warning: Connector Cv is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/TwoPhaseCavity.mo:185:3-187:61:writable] Warning: Connector Cl is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/TwoPhaseCavity.mo:200:3-201:67:writable] Warning: Connector Ce is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicOnePhaseFlowPipe.mo:150:3-151:67:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicOnePhaseFlowPipe.mo:152:3-153:65:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicWaterHeater.mo:98:3-99:65:writable] Warning: Connector C1vap is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicWaterHeater.mo:100:3-102:16:writable] Warning: Connector C2ex is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicWaterHeater.mo:103:3-104:76:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicWaterHeater.mo:105:3-106:74:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicWaterHeater.mo:111:3-112:74:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicOnePhaseFlowPipe.mo:150:3-151:67:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicOnePhaseFlowPipe.mo:152:3-153:65:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicOnePhaseFlowPipe.mo:150:3-151:67:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicOnePhaseFlowPipe.mo:152:3-153:65:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeC.mo:103:3-105:59:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeC.mo:106:3-108:57:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeC.mo:109:3-110:65:writable] Warning: Connector Cs is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeC.mo:111:3-113:24:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeD.mo:104:3-105:67:writable] Warning: Connector Ce is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeD.mo:106:3-107:73:writable] Warning: Connector Cs1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeD.mo:108:3-109:75:writable] Warning: Connector Cs2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeD.mo:110:3-111:71:writable] Warning: Connector Cs3 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeD.mo:104:3-105:67:writable] Warning: Connector Ce is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeD.mo:106:3-107:73:writable] Warning: Connector Cs1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeD.mo:108:3-109:75:writable] Warning: Connector Cs2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeD.mo:110:3-111:71:writable] Warning: Connector Cs3 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/BoundaryConditions/Sink.mo:39:3-40:67:writable] Warning: Connector C is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/SingularPressureLoss.mo:27:3-28:67:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/SingularPressureLoss.mo:29:3-30:65:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/SingularPressureLoss.mo:27:3-28:67:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/SingularPressureLoss.mo:29:3-30:65:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/BoundaryConditions/SourceP.mo:58:3-59:65:writable] Warning: Connector C is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/BoundaryConditions/RefQ.mo:10:3-11:67:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/BoundaryConditions/RefQ.mo:12:3-13:65:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/IdealCheckValve.mo:22:3-23:65:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/IdealCheckValve.mo:24:3-25:67:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/SingularPressureLoss.mo:27:3-28:67:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/SingularPressureLoss.mo:29:3-30:65:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/LumpedStraightPipe.mo:54:3-55:67:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/LumpedStraightPipe.mo:56:3-57:65:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). Notification: Performance of NFTyping.typeComponents: time 0.003223/2.427, allocations: 0.961 MB / 0.7655 GB, free: 1.426 MB / 0.5919 GB Notification: Performance of NFTyping.typeBindings: time 0.006906/2.434, allocations: 2.275 MB / 0.7677 GB, free: 1.336 MB / 0.5919 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Properties/WaterSteam/IF97_packages.mo:783:9-783:27:writable] Warning: cv was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Properties/WaterSteam/IF97_packages.mo:850:9-850:27:writable] Warning: cv was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Properties/WaterSteam/IF97_packages.mo:1088:9-1088:27:writable] Warning: cv was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Properties/WaterSteamSimple/prop4_Ph.mo:69:3-69:60:writable] Warning: dh1satp was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Properties/WaterSteamSimple/prop4_Ph.mo:69:3-69:60:writable] Warning: dh2satp was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Properties/WaterSteamSimple/prop4_Ph_der.mo:167:3-170:49:writable] Warning: du1satp_der was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Properties/WaterSteamSimple/prop4_Ph_der.mo:167:3-170:49:writable] Warning: du2satp_der was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Properties/Fluid/derDensity_derP_derh.mo:63:5-63:84:writable] Warning: T was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. Notification: Performance of NFTyping.typeClassSections: time 0.04823/2.482, allocations: 17.08 MB / 0.7844 GB, free: 0.793 MB / 0.5919 GB Notification: Performance of NFFlatten.flatten: time 0.03086/2.513, allocations: 31.29 MB / 0.815 GB, free: 0.8711 MB / 0.6075 GB Notification: Performance of NFFlatten.resolveConnections: time 0.02011/2.533, allocations: 11.03 MB / 0.8257 GB, free: 6.762 MB / 0.6231 GB Notification: Performance of NFEvalConstants.evaluate: time 0.0175/2.551, allocations: 9.017 MB / 0.8346 GB, free: 13.96 MB / 0.6387 GB Notification: Performance of NFSimplifyModel.simplify: time 0.02052/2.571, allocations: 10.78 MB / 0.8451 GB, free: 3.52 MB / 0.6387 GB Notification: Performance of NFPackage.collectConstants: time 0.00987/2.581, allocations: 2.816 MB / 0.8478 GB, free: 0.7031 MB / 0.6387 GB Notification: Performance of NFFlatten.collectFunctions: time 0.06679/2.648, allocations: 27.02 MB / 0.8742 GB, free: 6.105 MB / 0.67 GB Notification: Performance of NFScalarize.scalarize: time 0.0128/2.661, allocations: 8.004 MB / 0.882 GB, free: 14.23 MB / 0.6856 GB Notification: Performance of NFVerifyModel.verify: time 0.02368/2.685, allocations: 9.788 MB / 0.8916 GB, free: 4.543 MB / 0.6856 GB Notification: Performance of NFConvertDAE.convert: time 0.07469/2.759, allocations: 38.99 MB / 0.9297 GB, free: 14.78 MB / 0.7325 GB Notification: Performance of FrontEnd - DAE generated: time 1.245e-05/2.759, allocations: 0 / 0.9297 GB, free: 14.78 MB / 0.7325 GB Notification: Performance of FrontEnd: time 3.266e-06/2.759, allocations: 0 / 0.9297 GB, free: 14.78 MB / 0.7325 GB Notification: Performance of Transformations before backend: time 0.001324/2.761, allocations: 4 kB / 0.9297 GB, free: 14.78 MB / 0.7325 GB Notification: Model statistics after passing the front-end and creating the data structures used by the back-end: * Number of equations: 3465 * Number of variables: 3465 Notification: Performance of Generate backend data structure: time 0.08344/2.844, allocations: 18.56 MB / 0.9478 GB, free: 12.09 MB / 0.7481 GB Notification: Performance of prepare preOptimizeDAE: time 5.528e-05/2.844, allocations: 19.89 kB / 0.9478 GB, free: 12.07 MB / 0.7481 GB Notification: Performance of preOpt introduceOutputAliases (simulation): time 0.01051/2.855, allocations: 1.812 MB / 0.9496 GB, free: 10.25 MB / 0.7481 GB Notification: Performance of preOpt normalInlineFunction (simulation): time 0.01042/2.865, allocations: 1.484 MB / 0.951 GB, free: 8.762 MB / 0.7481 GB Notification: Performance of preOpt evaluateParameters (simulation): time 0.01974/2.885, allocations: 7.327 MB / 0.9582 GB, free: 1.414 MB / 0.7481 GB Notification: Performance of preOpt simplifyIfEquations (simulation): time 0.005066/2.89, allocations: 3.365 MB / 0.9615 GB, free: 13.55 MB / 0.7637 GB Notification: Performance of preOpt expandDerOperator (simulation): time 0.009191/2.899, allocations: 1.429 MB / 0.9629 GB, free: 12.12 MB / 0.7637 GB Notification: Performance of preOpt clockPartitioning (simulation): time 0.07542/2.975, allocations: 26.3 MB / 0.9886 GB, free: 0.5781 MB / 0.7794 GB Notification: Performance of preOpt findStateOrder (simulation): time 0.0007549/2.976, allocations: 59.44 kB / 0.9886 GB, free: 0.5195 MB / 0.7794 GB Notification: Performance of preOpt replaceEdgeChange (simulation): time 0.007592/2.983, allocations: 0.5554 MB / 0.9892 GB, free: 15.96 MB / 0.795 GB Notification: Performance of preOpt inlineArrayEqn (simulation): time 0.0004186/2.984, allocations: 363.9 kB / 0.9895 GB, free: 15.61 MB / 0.795 GB Notification: Performance of preOpt removeEqualRHS (simulation): time 0.5596/3.543, allocations: 68.29 MB / 1.056 GB, free: 356.5 MB / 0.795 GB Warning: The model contains alias variables with redundant start and/or conflicting nominal values. It is recommended to resolve the conflicts, because otherwise the system could be hard to solve. To print the conflicting alias sets and the chosen candidates please use -d=aliasConflicts. Notification: Performance of preOpt removeSimpleEquations (simulation): time 0.1525/3.696, allocations: 113.1 MB / 1.167 GB, free: 247.5 MB / 0.795 GB Notification: Performance of preOpt comSubExp (simulation): time 0.07767/3.774, allocations: 33.88 MB / 1.2 GB, free: 214.5 MB / 0.795 GB Notification: Performance of preOpt resolveLoops (simulation): time 0.02518/3.799, allocations: 12.88 MB / 1.212 GB, free: 201.6 MB / 0.795 GB Notification: Performance of preOpt evalFunc (simulation): time 1.553/5.352, allocations: 0.5988 GB / 1.811 GB, free: 340.6 MB / 0.795 GB Notification: Performance of preOpt encapsulateWhenConditions (simulation): time 0.03347/5.385, allocations: 14.46 MB / 1.825 GB, free: 338.8 MB / 0.795 GB Notification: Performance of pre-optimization done (n=1628): time 2.534e-05/5.386, allocations: 0 / 1.825 GB, free: 338.8 MB / 0.795 GB Notification: Performance of matching and sorting (n=1629): time 0.5333/5.919, allocations: 129.6 MB / 1.952 GB, free: 214.7 MB / 0.795 GB Notification: Performance of inlineWhenForInitialization (initialization): time 0.0002117/5.919, allocations: 498.4 kB / 1.952 GB, free: 214.2 MB / 0.795 GB Notification: Performance of selectInitializationVariablesDAE (initialization): time 0.00806/5.927, allocations: 5.089 MB / 1.957 GB, free: 209.2 MB / 0.795 GB Notification: Performance of collectPreVariables (initialization): time 0.004977/5.932, allocations: 301.7 kB / 1.957 GB, free: 208.9 MB / 0.795 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/LumpedStraightPipe.mo:10:3-11:71:writable] Warning: The parameter PressureLoss_Steam.lambda has fixed = false and a binding equation PressureLoss_Steam.lambda = 0.03, which is probably redundant. Setting fixed = false usually means there is an additional initial equation to determine the parameter value. The binding was ignored by old Modelica tools, but this is not according to the Modelica specification. Please remove the parameter binding, or bind the parameter to another parameter with fixed = false and no binding. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicWaterHeater.mo:38:3-38:111:writable] Warning: The parameter WaterHeating.COP0l has fixed = false and a binding equation WaterHeating.COP0l = 1.23, which is probably redundant. Setting fixed = false usually means there is an additional initial equation to determine the parameter value. The binding was ignored by old Modelica tools, but this is not according to the Modelica specification. Please remove the parameter binding, or bind the parameter to another parameter with fixed = false and no binding. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/ControlValve.mo:6:3-7:43:writable] Warning: The parameter ControlValve_eau.Cvmax has fixed = false and a binding equation ControlValve_eau.Cvmax = 354.534, which is probably redundant. Setting fixed = false usually means there is an additional initial equation to determine the parameter value. The binding was ignored by old Modelica tools, but this is not according to the Modelica specification. Please remove the parameter binding, or bind the parameter to another parameter with fixed = false and no binding. Notification: Performance of collectInitialEqns (initialization): time 0.003352/5.936, allocations: 4.167 MB / 1.962 GB, free: 205.2 MB / 0.795 GB Notification: Performance of collectInitialBindings (initialization): time 0.009184/5.945, allocations: 6.13 MB / 1.967 GB, free: 199.8 MB / 0.795 GB Notification: Performance of simplifyInitialFunctions (initialization): time 0.0193/5.964, allocations: 3.685 MB / 1.971 GB, free: 196.1 MB / 0.795 GB Notification: Performance of setup shared object (initialization): time 5.355e-05/5.964, allocations: 301.1 kB / 1.971 GB, free: 195.8 MB / 0.795 GB Notification: Performance of preBalanceInitialSystem (initialization): time 0.0263/5.991, allocations: 11.89 MB / 1.983 GB, free: 183.9 MB / 0.795 GB Notification: Performance of partitionIndependentBlocks (initialization): time 0.2852/6.276, allocations: 16.06 MB / 1.999 GB, free: 345.9 MB / 0.795 GB Notification: It was not possible to check the given initialization system for consistency symbolically, because the relevant equations are part of an algebraic loop. This is not supported yet. Notification: Performance of analyzeInitialSystem (initialization): time 1.581/7.857, allocations: 241.5 MB / 2.235 GB, free: 343.1 MB / 0.795 GB Notification: Performance of solveInitialSystemEqSystem (initialization): time 0.0001509/7.857, allocations: 34.19 kB / 2.235 GB, free: 343.1 MB / 0.795 GB Notification: Performance of matching and sorting (n=2352) (initialization): time 0.09612/7.953, allocations: 40.95 MB / 2.275 GB, free: 330.6 MB / 0.795 GB Notification: Performance of prepare postOptimizeDAE: time 0.0002674/7.953, allocations: 110.4 kB / 2.275 GB, free: 330.6 MB / 0.795 GB Notification: Performance of postOpt simplifyComplexFunction (initialization): time 0.0002774/7.953, allocations: 120.5 kB / 2.275 GB, free: 330.6 MB / 0.795 GB Notification: Performance of postOpt tearingSystem (initialization): time 1.475/9.428, allocations: 415.5 MB / 2.681 GB, free: 347.5 MB / 0.795 GB Notification: Performance of postOpt solveSimpleEquations (initialization): time 0.008992/9.437, allocations: 1.782 MB / 2.682 GB, free: 347.5 MB / 0.795 GB Notification: Performance of postOpt calculateStrongComponentJacobians (initialization): time 0.1299/9.567, allocations: 43.63 MB / 2.725 GB, free: 338 MB / 0.795 GB Notification: Performance of postOpt simplifyAllExpressions (initialization): time 0.02034/9.588, allocations: 0.8394 MB / 2.726 GB, free: 337.7 MB / 0.795 GB Notification: Performance of postOpt collapseArrayExpressions (initialization): time 0.007682/9.595, allocations: 0.9248 MB / 2.727 GB, free: 337.5 MB / 0.795 GB Warning: Assuming fixed start value for the following 1 variables: regulation_Niveau.pIsat1.Integrateur1.x0:DISCRETE(fixed = true protected = true ) type: Real Warning: The initial conditions are over specified. The following 3 initial equations are redundant, so they are removed from the initialization system: $DER.WaterHeating.pipe_3.Q[20] = 0.0 singularPressureLossPurge.T = $START.singularPressureLossPurge.T WaterHeating.WaterHeating.zl = $START.WaterHeating.WaterHeating.zl. Notification: Model statistics after passing the back-end for initialization: * Number of independent subsystems: 524 * Number of states: 0 () * Number of discrete variables: 83 ($PRE.regulation_Niveau.pIsat1.Integrateur1.x0,regulation_Niveau.pIsat1.Integrateur1.x0,$PRE.checkValve.touvert,$whenCondition2,$PRE.checkValve.tferme,$whenCondition1,sourceP.C.ftype,WaterHeating.WaterHeating.Cl.ftype,WaterHeating.volumeC.Cs.ftype,sourceP1.C.ftype,WaterHeating.C1.ftype,WaterHeating.volumeD1.Cs3.ftype,WaterHeating.volumeD1.Cs2.ftype,WaterHeating.volumeD1.Cs1.ftype,WaterHeating.volumeD.Cs2.ftype,WaterHeating.volumeD1.fluids[1],WaterHeating.volumeD.Cs3.ftype,WaterHeating.volumeD.Cs1.ftype,WaterHeating.volumeD.fluids[1],WaterHeating.volumeC.Ce2.ftype,WaterHeating.volumeC.fluids[1],WaterHeating.WaterHeating.fluids[1],Puit_condenseur1.fluid,ControlValve_eau.fluid,WaterHeating.pipe_3.fluid,WaterHeating.pipe_1.fluid,WaterHeating.pipe_2.fluid,Puit_condenseur2.fluid,singularPressureLossWaterIn.fluid,singularPressureLossWaterOut.fluid,singularPressureLossPurge.fluid,PressureLoss_Steam.fluid,checkValve.tferme,checkValve.touvert,checkValve.ouvert,$PRE.checkValve.ouvert,regulation_Niveau.echelon.yL.signal,regulation_Niveau.edge.yL.signal,regulation_Niveau.edge.uL.signal,$PRE.regulation_Niveau.edge.uL.signal,$whenCondition3,sourceP1.fluid1,WaterHeating.volumeD1.fluid1,WaterHeating.volumeD.fluid1,WaterHeating.volumeC.fluid1,sourceP.fluid1,WaterHeating.WaterHeating.Cv.diff_on_2,sourceP.C.diff_on_2,PressureLoss_Steam.C2.diff_on_1,singularPressureLossPurge.C2.diff_on_2,singularPressureLossPurge.C1.diff_on_2,WaterHeating.WaterHeating.Cl.diff_on_1,singularPressureLossPurge.C2.diff_on_1,ControlValve_eau.C2.diff_on_1,singularPressureLossWaterOut.C1.diff_on_2,WaterHeating.volumeC.Cs.diff_on_1,refQ.C2.diff_on_1,singularPressureLossWaterIn.C2.diff_on_1,WaterHeating.volumeD.Ce.diff_on_2,sourceP1.C.diff_on_2,WaterHeating.C1.diff_on_1,WaterHeating.volumeD1.Cs3.diff_on_1,WaterHeating.volumeD1.Cs2.diff_on_1,WaterHeating.volumeD1.Cs1.diff_on_1,WaterHeating.volumeD1.Ce.diff_on_2,WaterHeating.volumeD1.Cs2.diff_on_2,WaterHeating.volumeD1.Cs1.diff_on_2,WaterHeating.volumeD.Cs3.diff_on_1,WaterHeating.volumeD.Cs2.diff_on_1,WaterHeating.volumeD.Cs1.diff_on_1,WaterHeating.volumeD.Cs3.diff_on_2,WaterHeating.volumeC.Ce3.diff_on_2,WaterHeating.volumeC.Ce2.diff_on_2,WaterHeating.volumeC.Ce1.diff_on_2,WaterHeating.volumeC.Ce2.diff_on_1,WaterHeating.pipe_2.C1.diff_on_2,WaterHeating.pipe_2.C2.diff_on_1,WaterHeating.pipe_1.C1.diff_on_2,WaterHeating.pipe_1.C2.diff_on_1,WaterHeating.pipe_3.C1.diff_on_2,WaterHeating.pipe_3.C2.diff_on_1,WaterHeating.WaterHeating.Ce.diff_on_2,WaterHeating.WaterHeating.NbTubT) * Number of discrete states: 0 () * Number of clocked states: 0 () * Top-level inputs: 0 Notification: Strong component statistics for initialization (1010): * Single equations (assignments): 1003 * Array equations: 0 * Algorithm blocks: 2 * Record equations: 3 * When equations: 0 * If-equations: 0 * Equation systems (not torn): 0 * Torn equation systems: 2 * Mixed (continuous/discrete) equation systems: 0 Notification: Torn system details for strict tearing set: * Linear torn systems (#iteration vars, #inner vars, density): 0 systems * Non-linear torn systems (#iteration vars, #inner vars): 2 systems {(1,3), (140,1142)} Notification: Performance of prepare postOptimizeDAE: time 0.01925/9.615, allocations: 3.421 MB / 2.73 GB, free: 335.9 MB / 0.795 GB Notification: Performance of postOpt lateInlineFunction (simulation): time 0.007907/9.623, allocations: 1.009 MB / 2.731 GB, free: 335.9 MB / 0.795 GB Notification: Performance of postOpt wrapFunctionCalls (simulation): time 0.2099/9.832, allocations: 49.3 MB / 2.779 GB, free: 310 MB / 0.795 GB Notification: Performance of postOpt inlineArrayEqn (simulation): time 0.1677/10, allocations: 42.47 MB / 2.821 GB, free: 267.8 MB / 0.795 GB Notification: Performance of postOpt constantLinearSystem (simulation): time 0.0002691/10, allocations: 20 kB / 2.821 GB, free: 267.8 MB / 0.795 GB Notification: Performance of postOpt simplifysemiLinear (simulation): time 0.000533/10, allocations: 85 kB / 2.821 GB, free: 267.7 MB / 0.795 GB Warning: The model contains alias variables with redundant start and/or conflicting nominal values. It is recommended to resolve the conflicts, because otherwise the system could be hard to solve. To print the conflicting alias sets and the chosen candidates please use -d=aliasConflicts. Notification: Performance of postOpt removeSimpleEquations (simulation): time 0.2258/10.23, allocations: 68.08 MB / 2.887 GB, free: 199.6 MB / 0.795 GB Notification: Performance of postOpt simplifyComplexFunction (simulation): time 0.0001727/10.23, allocations: 7.984 kB / 2.887 GB, free: 199.6 MB / 0.795 GB Notification: Performance of postOpt solveSimpleEquations (simulation): time 0.01926/10.25, allocations: 2.951 MB / 2.89 GB, free: 196.8 MB / 0.795 GB Notification: Performance of postOpt tearingSystem (simulation): time 0.4335/10.68, allocations: 22.65 MB / 2.912 GB, free: 342 MB / 0.795 GB Notification: Performance of postOpt inputDerivativesUsed (simulation): time 0.008556/10.69, allocations: 0.7121 MB / 2.913 GB, free: 342 MB / 0.795 GB Notification: Performance of postOpt calculateStrongComponentJacobians (simulation): time 0.2521/10.94, allocations: 153.9 MB / 3.063 GB, free: 232.4 MB / 0.795 GB Notification: Performance of postOpt calculateStateSetsJacobians (simulation): time 5.931e-06/10.94, allocations: 6.797 kB / 3.063 GB, free: 232.4 MB / 0.795 GB Notification: Performance of postOpt symbolicJacobian (simulation): time 0.2069/11.15, allocations: 58.98 MB / 3.121 GB, free: 185 MB / 0.795 GB Notification: Performance of postOpt removeConstants (simulation): time 0.01345/11.16, allocations: 3.825 MB / 3.124 GB, free: 181.2 MB / 0.795 GB Notification: Performance of postOpt simplifyTimeIndepFuncCalls (simulation): time 0.008048/11.17, allocations: 448.7 kB / 3.125 GB, free: 180.8 MB / 0.795 GB Notification: Performance of postOpt simplifyAllExpressions (simulation): time 0.01777/11.19, allocations: 0.6204 MB / 3.125 GB, free: 180.2 MB / 0.795 GB Notification: Performance of postOpt findZeroCrossings (simulation): time 0.0112/11.2, allocations: 1.714 MB / 3.127 GB, free: 178.5 MB / 0.795 GB Notification: Performance of postOpt collapseArrayExpressions (simulation): time 0.006705/11.21, allocations: 0.6407 MB / 3.128 GB, free: 177.8 MB / 0.795 GB Notification: Performance of sorting global known variables: time 0.006556/11.21, allocations: 3.169 MB / 3.131 GB, free: 174.7 MB / 0.795 GB Notification: Performance of sort global known variables: time 3.6e-07/11.21, allocations: 4 kB / 3.131 GB, free: 174.7 MB / 0.795 GB Notification: Performance of remove unused functions: time 0.04088/11.25, allocations: 6.554 MB / 3.137 GB, free: 168.4 MB / 0.795 GB Notification: Model statistics after passing the back-end for simulation: * Number of independent subsystems: 15 * Number of states: 175 (WaterHeating.WaterHeating.P,WaterHeating.WaterHeating.hl,WaterHeating.WaterHeating.hv,WaterHeating.WaterHeating.Vv,WaterHeating.WaterHeating.Tp,WaterHeating.pipe_3.P[2],WaterHeating.pipe_3.P[3],WaterHeating.pipe_3.P[4],WaterHeating.pipe_3.P[5],WaterHeating.pipe_3.P[6],WaterHeating.pipe_3.P[7],WaterHeating.pipe_3.P[8],WaterHeating.pipe_3.P[9],WaterHeating.pipe_3.P[10],WaterHeating.pipe_3.P[11],WaterHeating.pipe_3.P[12],WaterHeating.pipe_3.P[13],WaterHeating.pipe_3.P[14],WaterHeating.pipe_3.P[15],WaterHeating.pipe_3.P[16],WaterHeating.pipe_3.P[17],WaterHeating.pipe_3.P[18],WaterHeating.pipe_3.P[19],WaterHeating.pipe_3.P[20],WaterHeating.pipe_3.P[21],WaterHeating.pipe_3.Q[1],WaterHeating.pipe_3.Q[2],WaterHeating.pipe_3.Q[3],WaterHeating.pipe_3.Q[4],WaterHeating.pipe_3.Q[5],WaterHeating.pipe_3.Q[6],WaterHeating.pipe_3.Q[7],WaterHeating.pipe_3.Q[8],WaterHeating.pipe_3.Q[9],WaterHeating.pipe_3.Q[10],WaterHeating.pipe_3.Q[11],WaterHeating.pipe_3.Q[12],WaterHeating.pipe_3.Q[13],WaterHeating.pipe_3.Q[14],WaterHeating.pipe_3.Q[15],WaterHeating.pipe_3.Q[16],WaterHeating.pipe_3.Q[17],WaterHeating.pipe_3.Q[18],WaterHeating.pipe_3.Q[19],WaterHeating.pipe_3.Q[20],WaterHeating.pipe_3.Q[21],WaterHeating.pipe_3.h[2],WaterHeating.pipe_3.h[3],WaterHeating.pipe_3.h[4],WaterHeating.pipe_3.h[5],WaterHeating.pipe_3.h[6],WaterHeating.pipe_3.h[7],WaterHeating.pipe_3.h[8],WaterHeating.pipe_3.h[9],WaterHeating.pipe_3.h[10],WaterHeating.pipe_3.h[11],WaterHeating.pipe_3.h[12],WaterHeating.pipe_3.h[13],WaterHeating.pipe_3.h[14],WaterHeating.pipe_3.h[15],WaterHeating.pipe_3.h[16],WaterHeating.pipe_3.h[17],WaterHeating.pipe_3.h[18],WaterHeating.pipe_3.h[19],WaterHeating.pipe_3.h[20],WaterHeating.pipe_3.h[21],WaterHeating.Wall_3.Tp[1],WaterHeating.Wall_3.Tp[2],WaterHeating.Wall_3.Tp[3],WaterHeating.Wall_3.Tp[4],WaterHeating.Wall_3.Tp[5],WaterHeating.Wall_3.Tp[6],WaterHeating.Wall_3.Tp[7],WaterHeating.Wall_3.Tp[8],WaterHeating.Wall_3.Tp[9],WaterHeating.Wall_3.Tp[10],WaterHeating.Wall_3.Tp[11],WaterHeating.Wall_3.Tp[12],WaterHeating.Wall_3.Tp[13],WaterHeating.Wall_3.Tp[14],WaterHeating.Wall_3.Tp[15],WaterHeating.Wall_3.Tp[16],WaterHeating.Wall_3.Tp[17],WaterHeating.Wall_3.Tp[18],WaterHeating.Wall_3.Tp[19],WaterHeating.Wall_3.Tp[20],WaterHeating.pipe_1.P[2],WaterHeating.pipe_1.P[3],WaterHeating.pipe_1.P[4],WaterHeating.pipe_1.P[5],WaterHeating.pipe_1.P[6],WaterHeating.pipe_1.P[7],WaterHeating.pipe_1.P[8],WaterHeating.pipe_1.P[9],WaterHeating.pipe_1.P[10],WaterHeating.pipe_1.P[11],WaterHeating.pipe_1.Q[1],WaterHeating.pipe_1.Q[2],WaterHeating.pipe_1.Q[3],WaterHeating.pipe_1.Q[4],WaterHeating.pipe_1.Q[5],WaterHeating.pipe_1.Q[6],WaterHeating.pipe_1.Q[7],WaterHeating.pipe_1.Q[8],WaterHeating.pipe_1.Q[9],WaterHeating.pipe_1.Q[10],WaterHeating.pipe_1.Q[11],WaterHeating.pipe_1.h[2],WaterHeating.pipe_1.h[3],WaterHeating.pipe_1.h[4],WaterHeating.pipe_1.h[5],WaterHeating.pipe_1.h[6],WaterHeating.pipe_1.h[7],WaterHeating.pipe_1.h[8],WaterHeating.pipe_1.h[9],WaterHeating.pipe_1.h[10],WaterHeating.pipe_1.h[11],WaterHeating.Wall_1.Tp[1],WaterHeating.Wall_1.Tp[2],WaterHeating.Wall_1.Tp[3],WaterHeating.Wall_1.Tp[4],WaterHeating.Wall_1.Tp[5],WaterHeating.Wall_1.Tp[6],WaterHeating.Wall_1.Tp[7],WaterHeating.Wall_1.Tp[8],WaterHeating.Wall_1.Tp[9],WaterHeating.Wall_1.Tp[10],WaterHeating.pipe_2.P[2],WaterHeating.pipe_2.P[3],WaterHeating.pipe_2.P[4],WaterHeating.pipe_2.P[5],WaterHeating.pipe_2.P[6],WaterHeating.pipe_2.P[7],WaterHeating.pipe_2.P[8],WaterHeating.pipe_2.P[9],WaterHeating.pipe_2.P[10],WaterHeating.pipe_2.P[11],WaterHeating.pipe_2.Q[1],WaterHeating.pipe_2.Q[2],WaterHeating.pipe_2.Q[3],WaterHeating.pipe_2.Q[4],WaterHeating.pipe_2.Q[5],WaterHeating.pipe_2.Q[6],WaterHeating.pipe_2.Q[7],WaterHeating.pipe_2.Q[8],WaterHeating.pipe_2.Q[9],WaterHeating.pipe_2.Q[10],WaterHeating.pipe_2.Q[11],WaterHeating.pipe_2.h[2],WaterHeating.pipe_2.h[3],WaterHeating.pipe_2.h[4],WaterHeating.pipe_2.h[5],WaterHeating.pipe_2.h[6],WaterHeating.pipe_2.h[7],WaterHeating.pipe_2.h[8],WaterHeating.pipe_2.h[9],WaterHeating.pipe_2.h[10],WaterHeating.pipe_2.h[11],WaterHeating.Wall_2.Tp[1],WaterHeating.Wall_2.Tp[2],WaterHeating.Wall_2.Tp[3],WaterHeating.Wall_2.Tp[4],WaterHeating.Wall_2.Tp[5],WaterHeating.Wall_2.Tp[6],WaterHeating.Wall_2.Tp[7],WaterHeating.Wall_2.Tp[8],WaterHeating.Wall_2.Tp[9],WaterHeating.Wall_2.Tp[10],WaterHeating.volumeC.P,WaterHeating.volumeC.h,WaterHeating.volumeD.h,WaterHeating.volumeD1.P,WaterHeating.volumeD1.h,regulation_Niveau.pIsat1.Integrateur1.x,regulation_Niveau.pT1_1.x) * Number of discrete variables: 11 ($whenCondition3,$whenCondition2,$whenCondition1,regulation_Niveau.pIsat1.Integrateur1.x0,regulation_Niveau.edge.uL.signal,regulation_Niveau.edge.yL.signal,regulation_Niveau.echelon.yL.signal,checkValve.ouvert,checkValve.touvert,checkValve.tferme,singularPressureLossPurge.C1.diff_on_2) * Number of discrete states: 5 (checkValve.touvert,checkValve.tferme,regulation_Niveau.echelon.yL.signal,regulation_Niveau.edge.yL.signal,regulation_Niveau.edge.uL.signal) * Number of clocked states: 0 () * Top-level inputs: 0 Notification: Strong component statistics for simulation (1392): * Single equations (assignments): 1256 * Array equations: 0 * Algorithm blocks: 2 * Record equations: 5 * When equations: 2 * If-equations: 0 * Equation systems (not torn): 42 * Torn equation systems: 85 * Mixed (continuous/discrete) equation systems: 0 Notification: Equation system details (not torn): * Constant Jacobian (size): 0 systems * Linear Jacobian (size,density): 42 systems {(2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%)} * Non-linear Jacobian (size): 0 systems * Without analytic Jacobian (size): 0 systems Notification: Torn system details for strict tearing set: * Linear torn systems (#iteration vars, #inner vars, density): 41 systems {(4,1,62.5%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%)} * Non-linear torn systems (#iteration vars, #inner vars): 44 systems {(1,3), (1,3), (1,3), (1,3), (1,3), (1,3), (1,3), (1,3), (2,6), (1,4), (1,4), (1,4), (1,4), (1,4), (1,4), (1,4), (1,4), (1,4), (1,4), (1,4), (1,4), (1,4), (1,4), (1,4), (1,4), (1,4), (1,4), (1,4), (1,4), (1,4), (1,4), (1,4), (1,4), (1,4), (1,4), (1,4), (1,4), (1,4), (1,4), (1,3), (1,3), (2,7), (3,10), (1,4)} Notification: Performance of Backend phase and start with SimCode phase: time 0.5468/11.8, allocations: 63.14 MB / 3.199 GB, free: 328.2 MB / 0.795 GB Notification: Performance of simCode: created initialization part: time 0.094/11.89, allocations: 32.21 MB / 3.23 GB, free: 321.5 MB / 0.795 GB Notification: Performance of simCode: created event and clocks part: time 1.079e-05/11.89, allocations: 3.656 kB / 3.23 GB, free: 321.5 MB / 0.795 GB Notification: Performance of simCode: created simulation system equations: time 0.05457/11.95, allocations: 27.59 MB / 3.257 GB, free: 303.3 MB / 0.795 GB Notification: Performance of simCode: created of all other equations (e.g. parameter, nominal, assert, etc): time 0.01988/11.97, allocations: 2.204 MB / 3.259 GB, free: 302.6 MB / 0.795 GB Notification: Performance of simCode: created linear, non-linear and system jacobian parts: time 0.7971/12.77, allocations: 180.2 MB / 3.435 GB, free: 309.8 MB / 0.795 GB Notification: Performance of simCode: some other stuff during SimCode phase: time 0.009974/12.78, allocations: 6.339 MB / 3.442 GB, free: 308.8 MB / 0.795 GB Notification: Performance of simCode: alias equations: time 0.02064/12.8, allocations: 4.739 MB / 3.446 GB, free: 308.8 MB / 0.795 GB Notification: Performance of simCode: all other stuff during SimCode phase: time 0.01801/12.81, allocations: 5.371 MB / 3.452 GB, free: 308.7 MB / 0.795 GB Notification: Performance of SimCode: time 2.445e-06/12.81, allocations: 0 / 3.452 GB, free: 308.7 MB / 0.795 GB Notification: Performance of buildModelFMU: Generate the FMI files: time 1.701/14.51, allocations: 0.5455 GB / 3.997 GB, free: 297.7 MB / 0.7952 GB Notification: Performance of buildModelFMU: Generate platform static: time 58.75/73.26, allocations: 8.547 kB / 3.997 GB, free: 297.7 MB / 0.7952 GB (rm -f ThermoSysPro_ThermoSysPro.Fluid.Examples.Book.SimpleExamples.HeatExchanger.DynamicWaterHeater.Islanding.pipe ; mkfifo ThermoSysPro_ThermoSysPro.Fluid.Examples.Book.SimpleExamples.HeatExchanger.DynamicWaterHeater.Islanding.pipe ; head -c 1048576 < ThermoSysPro_ThermoSysPro.Fluid.Examples.Book.SimpleExamples.HeatExchanger.DynamicWaterHeater.Islanding.pipe >> ../files/ThermoSysPro_ThermoSysPro.Fluid.Examples.Book.SimpleExamples.HeatExchanger.DynamicWaterHeater.Islanding.sim & python3 -m fmpy simulate --output-file ThermoSysPro_ThermoSysPro.Fluid.Examples.Book.SimpleExamples.HeatExchanger.DynamicWaterHeater.Islanding_res.csv --start-time 0 --stop-time 3000 --timeout 50 --relative-tolerance 1e-06 --interface-type ModelExchange --solver CVode --output-interval 1.2 ThermoSysPro_ThermoSysPro_Fluid_Examples_Book_SimpleExamples_HeatExchanger_DynamicWaterHeater_Islanding.fmu > ThermoSysPro_ThermoSysPro.Fluid.Examples.Book.SimpleExamples.HeatExchanger.DynamicWaterHeater.Islanding.pipe 2>&1)