Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr ThermoSysPro_ThermoSysPro.Examples.SimpleExamples.TestFan.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/package.mo): time 0.9216/0.9216, allocations: 150.9 MB / 167.2 MB, free: 14.52 MB / 142.1 MB " [Timeout remaining time 179] Using package ThermoSysPro with version 4.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/package.mo) Running command: "" <> buildModelFMU(ThermoSysPro.Examples.SimpleExamples.TestFan,fileNamePrefix="ThermoSysPro_ThermoSysPro_Examples_SimpleExamples_TestFan",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(ThermoSysPro.Examples.SimpleExamples.TestFan,fileNamePrefix="ThermoSysPro_ThermoSysPro_Examples_SimpleExamples_TestFan",fmuType="me",version="2.0",platforms={"static"}) [Timeout 660] "Notification: Performance of FrontEnd - loaded program: time 0.0004911/0.0004911, allocations: 17.27 kB / 239.3 MB, free: 2.195 MB / 190.1 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.05894/0.05944, allocations: 31.35 MB / 270.6 MB, free: 6.676 MB / 222.1 MB Notification: Automatically loaded package Complex 4.0.0 due to uses annotation from Modelica. Notification: Automatically loaded package ModelicaServices 4.0.0 due to uses annotation from Modelica. Notification: Automatically loaded package Modelica 4.0.0 due to usage. Notification: Performance of NFInst.instantiate(ThermoSysPro.Examples.SimpleExamples.TestFan): time 1.723/1.783, allocations: 300.2 MB / 0.5575 GB, free: 8.273 MB / 446.1 MB Notification: Performance of NFInst.instExpressions: time 0.18/1.963, allocations: 152.5 MB / 0.7064 GB, free: 15.21 MB / 0.5919 GB Notification: Performance of NFInst.updateImplicitVariability: time 0.001087/1.964, allocations: 8 kB / 0.7064 GB, free: 15.21 MB / 0.5919 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/BoundaryConditions/SourcePQ.mo:18:3-19:83:writable] Warning: Connector C is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/BoundaryConditions/Sink.mo:15:3-17:16:writable] Warning: Connector C is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/Volumes/VolumeATh.mo:49:3-51:16:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/Volumes/VolumeATh.mo:52:3-54:16:writable] Warning: Connector Cs2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/Volumes/VolumeATh.mo:55:3-56:83:writable] Warning: Connector Cs1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/Volumes/VolumeATh.mo:59:3-60:83:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/PressureLosses/SingularPressureLoss.mo:18:3-20:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/PressureLosses/SingularPressureLoss.mo:21:3-23:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/PressureLosses/SingularPressureLoss.mo:18:3-20:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/PressureLosses/SingularPressureLoss.mo:21:3-23:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/Machines/StaticFan.mo:57:3-59:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/Machines/StaticFan.mo:60:3-62:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/PressureLosses/CheckValve.mo:27:3-28:49:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/PressureLosses/CheckValve.mo:29:3-30:47:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/Volumes/VolumeATh.mo:49:3-51:16:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/Volumes/VolumeATh.mo:52:3-54:16:writable] Warning: Connector Cs2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/Volumes/VolumeATh.mo:55:3-56:83:writable] Warning: Connector Cs1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/Volumes/VolumeATh.mo:59:3-60:83:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/PressureLosses/SingularPressureLoss.mo:18:3-20:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/PressureLosses/SingularPressureLoss.mo:21:3-23:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/PressureLosses/SingularPressureLoss.mo:18:3-20:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/PressureLosses/SingularPressureLoss.mo:21:3-23:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/Machines/StaticFan.mo:57:3-59:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/Machines/StaticFan.mo:60:3-62:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/PressureLosses/CheckValve.mo:27:3-28:49:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/PressureLosses/CheckValve.mo:29:3-30:47:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/Junctions/Mixer2.mo:24:3-26:24:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/Junctions/Mixer2.mo:27:3-28:52:writable] Warning: Connector Cs is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/Junctions/Mixer2.mo:30:3-32:17:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/Volumes/VolumeDTh.mo:48:3-50:16:writable] Warning: Connector Ce is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/Volumes/VolumeDTh.mo:51:3-52:83:writable] Warning: Connector Cs1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/Volumes/VolumeDTh.mo:53:3-55:16:writable] Warning: Connector Cs2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/Volumes/VolumeDTh.mo:56:3-57:83:writable] Warning: Connector Cs3 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/Sensors/TemperatureSensor.mo:10:3-12:43:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/Sensors/TemperatureSensor.mo:13:3-15:38:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/Sensors/TemperatureSensor.mo:10:3-12:43:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/Sensors/TemperatureSensor.mo:13:3-15:38:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). Notification: Performance of NFTyping.typeComponents: time 0.001039/1.965, allocations: 230.3 kB / 0.7066 GB, free: 14.98 MB / 0.5919 GB Notification: Performance of NFTyping.typeBindings: time 0.001781/1.967, allocations: 499.4 kB / 0.7071 GB, free: 14.49 MB / 0.5919 GB Notification: Performance of NFTyping.typeClassSections: time 0.004284/1.971, allocations: 1.5 MB / 0.7085 GB, free: 12.99 MB / 0.5919 GB Notification: Performance of NFFlatten.flatten: time 0.003254/1.974, allocations: 2.372 MB / 0.7109 GB, free: 10.61 MB / 0.5919 GB Notification: Performance of NFFlatten.resolveConnections: time 0.001675/1.976, allocations: 1.268 MB / 0.7121 GB, free: 9.293 MB / 0.5919 GB Notification: Performance of NFEvalConstants.evaluate: time 0.001016/1.977, allocations: 0.8842 MB / 0.713 GB, free: 8.406 MB / 0.5919 GB Notification: Performance of NFSimplifyModel.simplify: time 0.001203/1.978, allocations: 1.074 MB / 0.714 GB, free: 7.328 MB / 0.5919 GB Notification: Performance of NFPackage.collectConstants: time 0.0002965/1.978, allocations: 244 kB / 0.7142 GB, free: 7.09 MB / 0.5919 GB Notification: Performance of NFFlatten.collectFunctions: time 0.002647/1.981, allocations: 1.199 MB / 0.7154 GB, free: 5.891 MB / 0.5919 GB Notification: Performance of NFScalarize.scalarize: time 0.000546/1.982, allocations: 0.4986 MB / 0.7159 GB, free: 5.391 MB / 0.5919 GB Notification: Performance of NFVerifyModel.verify: time 0.001384/1.983, allocations: 1.038 MB / 0.7169 GB, free: 4.348 MB / 0.5919 GB Notification: Performance of NFConvertDAE.convert: time 0.004118/1.987, allocations: 2.901 MB / 0.7197 GB, free: 1.441 MB / 0.5919 GB Notification: Performance of FrontEnd - DAE generated: time 4.448e-06/1.987, allocations: 0 / 0.7197 GB, free: 1.441 MB / 0.5919 GB Notification: Performance of FrontEnd: time 1.953e-06/1.987, allocations: 0 / 0.7197 GB, free: 1.441 MB / 0.5919 GB Notification: Performance of Transformations before backend: time 2.518e-05/1.987, allocations: 4 kB / 0.7198 GB, free: 1.438 MB / 0.5919 GB Notification: Model statistics after passing the front-end and creating the data structures used by the back-end: * Number of equations: 509 * Number of variables: 509 Notification: Performance of Generate backend data structure: time 0.1886/2.176, allocations: 2.29 MB / 0.722 GB, free: 222.9 MB / 0.5919 GB Notification: Performance of prepare preOptimizeDAE: time 4.176e-05/2.176, allocations: 10.78 kB / 0.722 GB, free: 222.9 MB / 0.5919 GB Notification: Performance of preOpt introduceOutputAliases (simulation): time 0.0003042/2.176, allocations: 278.2 kB / 0.7223 GB, free: 222.8 MB / 0.5919 GB Notification: Performance of preOpt normalInlineFunction (simulation): time 0.0003926/2.177, allocations: 231.1 kB / 0.7225 GB, free: 222.7 MB / 0.5919 GB Notification: Performance of preOpt evaluateParameters (simulation): time 0.0008414/2.177, allocations: 0.7429 MB / 0.7232 GB, free: 222.5 MB / 0.5919 GB Notification: Performance of preOpt simplifyIfEquations (simulation): time 0.0001659/2.178, allocations: 204.9 kB / 0.7234 GB, free: 222.4 MB / 0.5919 GB Notification: Performance of preOpt expandDerOperator (simulation): time 0.0004282/2.178, allocations: 219.5 kB / 0.7236 GB, free: 222.4 MB / 0.5919 GB Notification: Performance of preOpt clockPartitioning (simulation): time 0.003353/2.181, allocations: 2.351 MB / 0.7259 GB, free: 222 MB / 0.5919 GB Notification: Performance of preOpt findStateOrder (simulation): time 4.53e-05/2.181, allocations: 10.03 kB / 0.7259 GB, free: 222 MB / 0.5919 GB Notification: Performance of preOpt replaceEdgeChange (simulation): time 0.0001483/2.182, allocations: 85.94 kB / 0.726 GB, free: 222 MB / 0.5919 GB Notification: Performance of preOpt inlineArrayEqn (simulation): time 4.732e-05/2.182, allocations: 51.78 kB / 0.7261 GB, free: 222 MB / 0.5919 GB Notification: Performance of preOpt removeEqualRHS (simulation): time 0.003502/2.185, allocations: 2.084 MB / 0.7281 GB, free: 221.9 MB / 0.5919 GB Warning: The model contains alias variables with redundant start and/or conflicting nominal values. It is recommended to resolve the conflicts, because otherwise the system could be hard to solve. To print the conflicting alias sets and the chosen candidates please use -d=aliasConflicts. Notification: Performance of preOpt removeSimpleEquations (simulation): time 0.009642/2.195, allocations: 14.51 MB / 0.7423 GB, free: 210.9 MB / 0.5919 GB Notification: Performance of preOpt comSubExp (simulation): time 0.00169/2.196, allocations: 1.098 MB / 0.7433 GB, free: 210.9 MB / 0.5919 GB Notification: Performance of preOpt resolveLoops (simulation): time 0.001144/2.198, allocations: 0.8233 MB / 0.7441 GB, free: 210.8 MB / 0.5919 GB Notification: Performance of preOpt evalFunc (simulation): time 0.0005901/2.198, allocations: 498.2 kB / 0.7446 GB, free: 210.5 MB / 0.5919 GB Notification: Performance of preOpt encapsulateWhenConditions (simulation): time 0.00134/2.2, allocations: 0.7975 MB / 0.7454 GB, free: 210.4 MB / 0.5919 GB Notification: Performance of pre-optimization done (n=129): time 3.747e-06/2.2, allocations: 0 / 0.7454 GB, free: 210.4 MB / 0.5919 GB Warning: Some equations could not be differentiated for following variables having attribute stateSelect=StateSelect.prefer. They will be treated as if they had stateSelect=StateSelect.default ======================================== 1: volume2S.T Please use -d=bltdump for more information. Notification: Performance of matching and sorting (n=214): time 0.1543/2.354, allocations: 32.41 MB / 0.777 GB, free: 189.6 MB / 0.5919 GB " [Timeout remaining time 658] [Calling sys.exit(0), Time elapsed: 3.9495400509331375] Failed to read output from testmodel.py, exit status != 0: 2.4874313520267606 2.498165243 0.508903973 Calling exit ...