Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr ThermoSysPro_ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump4.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/package.mo", uses=false) Using package ThermoSysPro with version 4.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/package.mo) Running command: "" <> buildModelFMU(ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump4,fileNamePrefix="ThermoSysPro_ThermoSysPro_Examples_SimpleExamples_TestCentrifugalPump4",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump4,fileNamePrefix="ThermoSysPro_ThermoSysPro_Examples_SimpleExamples_TestCentrifugalPump4",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/package.mo): time 0.9128/0.9128, allocations: 150.9 MB / 166.5 MB, free: 14.38 MB / 142.1 MB Notification: Performance of FrontEnd - loaded program: time 0.000525/0.000525, allocations: 17.08 kB / 236.6 MB, free: 2.016 MB / 190.1 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.06522/0.06577, allocations: 31.35 MB / 267.9 MB, free: 7.527 MB / 222.1 MB Notification: Automatically loaded package Complex 4.0.0 due to uses annotation from Modelica. Notification: Automatically loaded package ModelicaServices 4.0.0 due to uses annotation from Modelica. Notification: Automatically loaded package Modelica 4.0.0 due to usage. Notification: Performance of NFInst.instantiate(ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump4): time 1.838/1.904, allocations: 297 MB / 0.5517 GB, free: 11.23 MB / 446.1 MB Notification: Performance of NFInst.instExpressions: time 0.5966/2.501, allocations: 183.9 MB / 0.7313 GB, free: 0.6602 MB / 0.5919 GB Notification: Performance of NFInst.updateImplicitVariability: time 0.0004913/2.501, allocations: 5.875 kB / 0.7313 GB, free: 0.6602 MB / 0.5919 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/CentrifugalPump.mo:118:3-120:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/CentrifugalPump.mo:121:3-123:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/CentrifugalPump.mo:127:3-131:23:writable] Warning: Connector M is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/Tank.mo:71:3-72:53:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/Tank.mo:73:3-74:53:writable] Warning: Connector Cs2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/Tank.mo:78:3-79:55:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/Tank.mo:80:3-81:51:writable] Warning: Connector Cs1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/ControlValve.mo:45:3-47:43:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/ControlValve.mo:48:3-50:38:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/LumpedStraightPipe.mo:49:3-50:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/LumpedStraightPipe.mo:51:3-53:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/ElectroMechanics/BoundaryConditions/SourceMechanicalPower.mo:5:3-9:24:writable] Warning: Connector M is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). Notification: Performance of NFTyping.typeComponents: time 0.0007003/2.502, allocations: 178.3 kB / 0.7315 GB, free: 0.6602 MB / 0.5919 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/CentrifugalPump.mo:74:3-74:88:writable] Error: cardinality may only be used in the condition of an if-statement/equation or an assert. Notification: Performance of FrontEnd: time 0.0001206/2.502, allocations: 38.95 kB / 0.7316 GB, free: 0.6562 MB / 0.5919 GB