Environment - simulationEnvironment: startTime=0 stopTime=1 tolerance=1e-06 numberOfIntervals=500 stepSize=0.002 Regular simulation: ./PowerGrids_dev_PowerGrids.Examples.IEEE14bus.IEEE14busStaticNetwork -abortSlowSimulation -alarm=50 -emit_protected -lv LOG_STATS LOG_STDOUT | info | Using sparse solver kinsol for nonlinear system 20 (1947), | | | | because density of 0.09 remains under threshold of 0.10. LOG_STDOUT | info | Using sparse solver kinsol for nonlinear system 21 (2537), | | | | because density of 0.01 remains under threshold of 0.10. LOG_STDOUT | info | Using sparse solver kinsol for nonlinear system 43 (7134), | | | | because density of 0.01 remains under threshold of 0.10. LOG_STDOUT | info | The maximum density for using sparse solvers can be specified | | | | using the runtime flag '<-nlssMaxDensity=value>'. LOG_STDOUT | warning | Internal Numerical Jacobians without coloring are currently not supported by IDA with KLU. Colored numerical Jacobian will be used. LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/Buses/ReferenceBus.mo:56:3-58:100:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((1e-8 * abs(bus1.QSlack) < 0.01)) --> "The reactive power flowing into or out of the reference bus is above 0.01 pu. | | | | You probably need a better setup of excitation voltages, or you can set setPhaseOnly = true on the reference bus. | | | | Please check the documentation of ReferenceBus for further reference" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/Buses/ReferenceBus.mo:53:3-55:100:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((1e-8 * abs(bus1.PSlack) < 0.01)) --> "The active power flowing into or out of the reference bus is above 0.01 pu. | | | | You probably need a better balancing of the active power generators in the system. | | | | Please check the documentation of ReferenceBus for further reference" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/SolutionChecking.mo:35:5-35:162:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((bus1.IPuCheck < bus1.IPuMax)) --> "Current too high (IPu=7.95425 > 2.5), check if the numerical solution is valid" LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.104642s reading init.xml | | | | | | 0.0111902s reading info.xml | | | | | | 0.215907s [ 73.5%] pre-initialization | | | | | | 0.00354445s [ 1.2%] initialization | | | | | | 4.9213e-05s [ 0.0%] steps | | | | | | 0.0121027s [ 4.1%] solver (excl. callbacks) | | | | | | 0.00901775s [ 3.1%] creating output-file | | | | | | 0.000193643s [ 0.1%] event-handling | | | | | | 0.0127314s [ 4.3%] overhead | | | | | | 0.0400247s [ 13.6%] simulation | | | | | | 0.293571s [100.0%] total | | | | | events | | | | | | 0 state events | | | | | | 0 time events | | | | | solver: ida | | | | | | 21 steps taken | | | | | | 21 calls of functionODE | | | | | | 19 evaluations of jacobian | | | | | | 0 error test failures | | | | | | 0 convergence test failures | | | | | | 0.00485645s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.