Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr Dynawo_Dynawo.Examples.ENTSOE.TestCase2.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.001616/0.001616, allocations: 107.4 kB / 16.4 MB, free: 6.496 MB / 14.72 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001995/0.001995, allocations: 191.7 kB / 19.36 MB, free: 3.75 MB / 14.72 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.448/1.448, allocations: 205.1 MB / 227.2 MB, free: 12.14 MB / 190.1 MB " [Timeout remaining time 178] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.6.0/package.mo", uses=false) [Timeout 180] "[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.6.0/NonElectrical/Logs/package.mo:15:1-17:9:writable] Warning: TimelineKeys was referenced in the package.order file, but was not found in package.mo, TimelineKeys/package.mo or TimelineKeys.mo. Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.6.0/package.mo): time 0.3054/0.3054, allocations: 70.82 MB / 347.4 MB, free: 2.957 MB / 286.1 MB " [Timeout remaining time 179] Using package Dynawo with version 1.6.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.6.0/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Ignoring simflag -noemit -emit_protected=() since it seems broken on HelloWorld Running command: "" <> buildModelFMU(Dynawo.Examples.ENTSOE.TestCase2,fileNamePrefix="Dynawo_Dynawo_Examples_ENTSOE_TestCase2",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(Dynawo.Examples.ENTSOE.TestCase2,fileNamePrefix="Dynawo_Dynawo_Examples_ENTSOE_TestCase2",fmuType="me",version="2.0",platforms={"static"}) [Timeout 660] "Notification: Modelica requested package Complex of version 3.2.3. Complex 4.0.0 is used instead which states that it is fully compatible without conversion script needed. Notification: Modelica requested package ModelicaServices of version 3.2.3. ModelicaServices 4.0.0 is used instead which states that it is fully compatible without conversion script needed. Notification: Performance of FrontEnd - loaded program: time 0.0021/0.0021, allocations: 71.91 kB / 495.5 MB, free: 4.25 MB / 366.1 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.3369/0.339, allocations: 64.04 MB / 0.5464 GB, free: 4.004 MB / 398.1 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.6.0/Electrical/Controls/Machines/VoltageRegulators/Standard/SEXS.mo:39:81-39:111:writable] Notification: From here: [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/Blocks/Continuous.mo:1299:5-1299:47:writable] Error: Protected element 'x_scaled' may not be modified, got 'x_scaled(start = {Efd0Pu/K})'. Notification: Performance of FrontEnd: time 0.004128/0.3432, allocations: 3.488 MB / 0.5498 GB, free: 1.23 MB / 398.1 MB " [Timeout remaining time 660] [Calling sys.exit(0), Time elapsed: 3.1642354229697958] Failed to read output from testmodel.py, exit status != 0: 0.34952928801067173 0.36322415899999994 -1.0 Calling exit ...