Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr Buildings_latest_Buildings.Fluid.Geothermal.ZonedBorefields.Validation.FEFLOW.MassFlowRateStep100.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.0.0-master/package.mo", uses=false) Using package Buildings with version 12.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.0.0-master/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Running command: "" <> buildModelFMU(Buildings.Fluid.Geothermal.ZonedBorefields.Validation.FEFLOW.MassFlowRateStep100,fileNamePrefix="Buildings_latest_Buildings_Fluid_Geothermal_ZonedBorefields_Validation_FEFLOW_MassFlowRateStep100",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(Buildings.Fluid.Geothermal.ZonedBorefields.Validation.FEFLOW.MassFlowRateStep100,fileNamePrefix="Buildings_latest_Buildings_Fluid_Geothermal_ZonedBorefields_Validation_FEFLOW_MassFlowRateStep100",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.006526/0.006526, allocations: 97.62 kB / 15.73 MB, free: 6.047 MB / 14.72 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001573/0.001573, allocations: 202.7 kB / 16.68 MB, free: 5.969 MB / 14.72 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.42/1.42, allocations: 222.9 MB / 240.4 MB, free: 4.352 MB / 190.1 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.0.0-master/package.mo): time 2.919/2.919, allocations: 482.4 MB / 0.7548 GB, free: 10.9 MB / 0.6075 GB Notification: Performance of FrontEnd - loaded program: time 0.001943/0.001943, allocations: 67.89 kB / 1.083 GB, free: 12.51 MB / 0.8419 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2951/0.297, allocations: 162.2 MB / 1.241 GB, free: 10.17 MB / 0.9981 GB Notification: Performance of NFInst.instantiate(Buildings.Fluid.Geothermal.ZonedBorefields.Validation.FEFLOW.MassFlowRateStep100): time 0.649/0.9461, allocations: 97.84 MB / 1.337 GB, free: 13.62 MB / 1.061 GB Notification: Performance of NFInst.instExpressions: time 0.05039/0.9965, allocations: 32.28 MB / 1.369 GB, free: 6.496 MB / 1.076 GB Notification: Performance of NFInst.updateImplicitVariability: time 0.006384/1.003, allocations: 139.1 kB / 1.369 GB, free: 6.449 MB / 1.076 GB Notification: Performance of NFTyping.typeComponents: time 0.008132/1.011, allocations: 2.646 MB / 1.371 GB, free: 5.066 MB / 1.076 GB Notification: Performance of NFTyping.typeBindings: time 0.01584/1.027, allocations: 4.905 MB / 1.376 GB, free: 1.215 MB / 1.076 GB Notification: Performance of NFTyping.typeClassSections: time 0.01589/1.043, allocations: 5.441 MB / 1.381 GB, free: 13.19 MB / 1.092 GB [/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/Compiler/NFFrontEnd/NFExpression.mo:1599:7-1600:100:writable] Error: Internal error NFExpression.makeSubscriptedExp: too few dimensions in Buildings.Fluid.Geothermal.Borefields.Data.Configuration.Template(Buildings.Fluid.Geothermal.Borefields.Types.BoreholeConfiguration.DoubleUTubeParallel, false, 0.0, ({0.23045972222222225, 0.23045972222222225})[], ({5.531033333333334, 0.921838888888889})[], ({34000.0, 34000.0})[], 85.0, 0.075, 0.5, ({24, 4})[], {{3.0, 1.5}, {6.0, 1.5}, {9.0, 1.5}, {12.0, 1.5}, {1.5, 4.5}, {4.5, 4.5}, {7.5, 4.5}, {10.5, 4.5}, {3.0, 7.5}, {6.0, 7.5}, {9.0, 7.5}, {12.0, 7.5}, {1.5, 10.5}, {4.5, 10.5}, {7.5, 10.5}, {10.5, 10.5}, {3.0, 13.5}, {6.0, 13.5}, {9.0, 13.5}, {12.0, 13.5}, {1.5, 16.5}, {4.5, 16.5}, {7.5, 16.5}, {10.5, 16.5}, {5.4, 22.5}, {10.8, 22.5}, {2.7, 28.5}, {8.1, 28.5}}, 0.016, 0.42, 0.0029, 0.0282842712474619, ({2.3045972222222227e-5, 2.3045972222222227e-5})[]) to apply subscripts [] [/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/Compiler/NFFrontEnd/NFCeval.mo:1795:9-1796:93:writable] Error: Internal error NFCeval.evalRelationEqual failed to evaluate ‘borFie.borHol.borFieDat.conDat.borCon == Buildings.Fluid.Geothermal.Borefields.Types.BoreholeConfiguration.DoubleUTubeParallel‘ [/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/Compiler/NFFrontEnd/NFCeval.mo:1528:9-1528:67:writable] Error: Internal error NFCeval.evalLogicBinaryAnd failed to evaluate ‘true and borFie.borHol.borFieDat.conDat.borCon == Buildings.Fluid.Geothermal.Borefields.Types.BoreholeConfiguration.DoubleUTubeParallel‘ Notification: Performance of FrontEnd: time 0.01108/1.054, allocations: 7.206 MB / 1.388 GB, free: 8.898 MB / 1.092 GB