Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr Buildings_latest_Buildings.Fluid.Geothermal.ZonedBorefields.Validation.FEFLOW.MassFlowRatePulse100.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.0.0-master/package.mo", uses=false) Using package Buildings with version 12.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.0.0-master/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Running command: "" <> buildModelFMU(Buildings.Fluid.Geothermal.ZonedBorefields.Validation.FEFLOW.MassFlowRatePulse100,fileNamePrefix="Buildings_latest_Buildings_Fluid_Geothermal_ZonedBorefields_Validation_FEFLOW_MassFlowRatePulse100",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(Buildings.Fluid.Geothermal.ZonedBorefields.Validation.FEFLOW.MassFlowRatePulse100,fileNamePrefix="Buildings_latest_Buildings_Fluid_Geothermal_ZonedBorefields_Validation_FEFLOW_MassFlowRatePulse100",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.008352/0.008352, allocations: 97.78 kB / 15.73 MB, free: 5.996 MB / 14.72 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.002173/0.002173, allocations: 186.4 kB / 16.67 MB, free: 5.926 MB / 14.72 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.424/1.424, allocations: 222.9 MB / 240.4 MB, free: 4.328 MB / 190.1 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.0.0-master/package.mo): time 2.911/2.911, allocations: 482.4 MB / 0.7548 GB, free: 10.88 MB / 0.6075 GB Notification: Performance of FrontEnd - loaded program: time 0.001929/0.001929, allocations: 63.91 kB / 1.083 GB, free: 12.56 MB / 0.8419 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.3317/0.3337, allocations: 162.2 MB / 1.241 GB, free: 10.22 MB / 0.9981 GB Notification: Performance of NFInst.instantiate(Buildings.Fluid.Geothermal.ZonedBorefields.Validation.FEFLOW.MassFlowRatePulse100): time 0.6345/0.9682, allocations: 97.79 MB / 1.337 GB, free: 13.69 MB / 1.061 GB Notification: Performance of NFInst.instExpressions: time 0.04918/1.017, allocations: 32.31 MB / 1.369 GB, free: 6.543 MB / 1.076 GB Notification: Performance of NFInst.updateImplicitVariability: time 0.006001/1.023, allocations: 139.8 kB / 1.369 GB, free: 6.496 MB / 1.076 GB Notification: Performance of NFTyping.typeComponents: time 0.008064/1.032, allocations: 2.644 MB / 1.371 GB, free: 5.117 MB / 1.076 GB Notification: Performance of NFTyping.typeBindings: time 0.01489/1.046, allocations: 4.903 MB / 1.376 GB, free: 1.25 MB / 1.076 GB Notification: Performance of NFTyping.typeClassSections: time 0.01521/1.062, allocations: 5.453 MB / 1.381 GB, free: 13.22 MB / 1.092 GB [/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/Compiler/NFFrontEnd/NFExpression.mo:1599:7-1600:100:writable] Error: Internal error NFExpression.makeSubscriptedExp: too few dimensions in Buildings.Fluid.Geothermal.Borefields.Data.Configuration.Template(Buildings.Fluid.Geothermal.Borefields.Types.BoreholeConfiguration.DoubleUTubeParallel, false, 0.0, ({0.23045972222222225, 0.23045972222222225})[], ({5.531033333333334, 0.921838888888889})[], ({34000.0, 34000.0})[], 85.0, 0.075, 0.5, ({24, 4})[], {{3.0, 1.5}, {6.0, 1.5}, {9.0, 1.5}, {12.0, 1.5}, {1.5, 4.5}, {4.5, 4.5}, {7.5, 4.5}, {10.5, 4.5}, {3.0, 7.5}, {6.0, 7.5}, {9.0, 7.5}, {12.0, 7.5}, {1.5, 10.5}, {4.5, 10.5}, {7.5, 10.5}, {10.5, 10.5}, {3.0, 13.5}, {6.0, 13.5}, {9.0, 13.5}, {12.0, 13.5}, {1.5, 16.5}, {4.5, 16.5}, {7.5, 16.5}, {10.5, 16.5}, {5.4, 22.5}, {10.8, 22.5}, {2.7, 28.5}, {8.1, 28.5}}, 0.016, 0.42, 0.0029, 0.0282842712474619, ({2.3045972222222227e-5, 2.3045972222222227e-5})[]) to apply subscripts [] [/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/Compiler/NFFrontEnd/NFCeval.mo:1795:9-1796:93:writable] Error: Internal error NFCeval.evalRelationEqual failed to evaluate ‘borFie.borHol.borFieDat.conDat.borCon == Buildings.Fluid.Geothermal.Borefields.Types.BoreholeConfiguration.DoubleUTubeParallel‘ [/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/Compiler/NFFrontEnd/NFCeval.mo:1528:9-1528:67:writable] Error: Internal error NFCeval.evalLogicBinaryAnd failed to evaluate ‘true and borFie.borHol.borFieDat.conDat.borCon == Buildings.Fluid.Geothermal.Borefields.Types.BoreholeConfiguration.DoubleUTubeParallel‘ Notification: Performance of FrontEnd: time 0.01023/1.072, allocations: 7.204 MB / 1.388 GB, free: 8.926 MB / 1.092 GB