python3 -m fmpy simulate --output-file BuildingSystems_BuildingSystems.Applications.HeatingSystems.HeatPumpHeatingSystem_res.csv --start-time 0 --stop-time 3.1536e+07 --timeout 50 --relative-tolerance 1e-06 --interface-type ModelExchange --solver CVode --output-interval 12614.4 BuildingSystems_BuildingSystems_Applications_HeatingSystems_HeatPumpHeatingSystem.fmu LOG_STDOUT | info | ... loading "tab1" from "/tmp/tmp0mglw029/resources/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Climate/weather/Germany_Berlin.txt" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:389:3-396:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((pump.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning in HeatPumpHeatingSystem.pump: Mover is flow or pressure controlled and uses default pressure curve. | | | | This leads to an approximate power consumption. | | | | Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning."