python3 -m fmpy simulate --output-file BuildingSystems_BuildingSystems.Applications.AirConditioningSystems.PhotovoltaicCoolingSystem_res.csv --start-time 0 --stop-time 3.1536e+07 --timeout 50 --relative-tolerance 1e-06 --interface-type ModelExchange --solver CVode --output-interval 12614.4 BuildingSystems_BuildingSystems_Applications_AirConditioningSystems_PhotovoltaicCoolingSystem.fmu LOG_STDOUT | info | ... loading "tab1" from "/tmp/tmp4j9wd0p3/resources/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Climate/weather/Brazil_Manaus.txt" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Surfaces/SurfaceToAir.mo:18:3-18:68:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((building.surfacesToAmbience.surface[1].x >= 0.0 and building.surfacesToAmbience.surface[1].x <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= building.surfacesToAmbience.surface[1].x <= 1.0, has value: -7.40757e-44" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Surfaces/SurfaceToAir.mo:18:3-18:68:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((building.surfacesToAmbience.surface[2].x >= 0.0 and building.surfacesToAmbience.surface[2].x <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= building.surfacesToAmbience.surface[2].x <= 1.0, has value: -7.40757e-44" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Surfaces/SurfaceToAir.mo:18:3-18:68:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((building.surfacesToAmbience.surface[3].x >= 0.0 and building.surfacesToAmbience.surface[3].x <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= building.surfacesToAmbience.surface[3].x <= 1.0, has value: -7.40757e-44" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Surfaces/SurfaceToAir.mo:18:3-18:68:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((building.surfacesToAmbience.surface[4].x >= 0.0 and building.surfacesToAmbience.surface[4].x <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= building.surfacesToAmbience.surface[4].x <= 1.0, has value: -7.40757e-44" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Surfaces/SurfaceToAir.mo:18:3-18:68:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((building.surfacesToAmbience.surface[5].x >= 0.0 and building.surfacesToAmbience.surface[5].x <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= building.surfacesToAmbience.surface[5].x <= 1.0, has value: -7.40757e-44" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Surfaces/SurfaceToAir.mo:18:3-18:68:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((building.surfacesToAmbience.surface[6].x >= 0.0 and building.surfacesToAmbience.surface[6].x <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= building.surfacesToAmbience.surface[6].x <= 1.0, has value: -7.40757e-44" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Surfaces/SurfaceToAir.mo:18:3-18:68:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((building.surfacesToAmbience.surface[7].x >= 0.0 and building.surfacesToAmbience.surface[7].x <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= building.surfacesToAmbience.surface[7].x <= 1.0, has value: -7.40757e-44" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Surfaces/SurfaceToAir.mo:18:3-18:68:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((building.surfacesToAmbience.surface[8].x >= 0.0 and building.surfacesToAmbience.surface[8].x <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= building.surfacesToAmbience.surface[8].x <= 1.0, has value: -7.40757e-44" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Surfaces/SurfaceToAir.mo:18:3-18:68:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((building.surfacesToAmbience.surface[9].x >= 0.0 and building.surfacesToAmbience.surface[9].x <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= building.surfacesToAmbience.surface[9].x <= 1.0, has value: -7.40757e-44" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Climate/WeatherData/BaseClasses/WeatherDataFileGeneral.mo:16:3-17:24:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((ambience.weatherDataReader.weatherData.phiAir >= 0.0 and ambience.weatherDataReader.weatherData.phiAir <= 1.01)) --> "Variable violating min/max constraint: 0.0 <= ambience.weatherDataReader.weatherData.phiAir <= 1.01, has value: 1.0275" LOG_ASSERT | debug | Solving non-linear system 4849 failed at time=7311.99079565122. | | | | For more information please use -lv LOG_NLS. Exception ignored on calling ctypes callback function: > Traceback (most recent call last): File "/usr/local/lib/python3.10/dist-packages/fmpy/sundials/__init__.py", line 141, in f self.get_dx(NV_DATA_S(ydot), self.nx) File "/usr/local/lib/python3.10/dist-packages/fmpy/fmi2.py", line 505, in getDerivatives return self.fmi2GetDerivatives(self.component, dx, nx) File "/usr/local/lib/python3.10/dist-packages/fmpy/fmi2.py", line 215, in w raise FMICallException(function=fname, status=res) fmpy.fmi1.FMICallException: fmi2GetDerivatives failed with status 3 (error).