python3 -m fmpy simulate --output-file AixLib_AixLib.Fluid.Examples.GeothermalHeatPump.GeothermalHeatPump_res.csv --start-time 0 --stop-time 86400 --timeout 50 --relative-tolerance 1e-06 --interface-type ModelExchange --solver CVode --output-interval 502.326 AixLib_AixLib_Fluid_Examples_GeothermalHeatPump_GeothermalHeatPump.fmu LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 2.1.0/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:391:3-398:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((pumpColdConsumer.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning in GeothermalHeatPump.pumpColdConsumer: Mover is flow or pressure controlled and uses default pressure curve. | | | | This leads to an approximate power consumption. | | | | Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 2.1.0/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:391:3-398:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((pumpHeatConsumer.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning in GeothermalHeatPump.pumpHeatConsumer: Mover is flow or pressure controlled and uses default pressure curve. | | | | This leads to an approximate power consumption. | | | | Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 2.1.0/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:391:3-398:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((pumpCondenser.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning in GeothermalHeatPump.pumpCondenser: Mover is flow or pressure controlled and uses default pressure curve. | | | | This leads to an approximate power consumption. | | | | Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 2.1.0/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:391:3-398:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((pumpEvaporator.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning in GeothermalHeatPump.pumpEvaporator: Mover is flow or pressure controlled and uses default pressure curve. | | | | This leads to an approximate power consumption. | | | | Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 2.1.0/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:391:3-398:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((pumpGeothermalSource.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning in GeothermalHeatPump.pumpGeothermalSource: Mover is flow or pressure controlled and uses default pressure curve. | | | | This leads to an approximate power consumption. | | | | Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning." LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 2.1.0/Media/Water.mo:63:5-64:119:writable] | | | | The following assertion has been violated at time 4175.090533 | | | | ((noEvent(heatPump.eva.vol.dynBal.medium.T >= 272.15))) --> "In GeothermalHeatPump.heatPump.eva.vol.dynBal.medium: Temperature T = 270.199 K exceeded its minimum allowed value of -1 degC (272.15 Kelvin) as required from medium model "AixLib.Media.Water"." Traceback (most recent call last): File "/usr/lib/python3.10/runpy.py", line 196, in _run_module_as_main return _run_code(code, main_globals, None, File "/usr/lib/python3.10/runpy.py", line 86, in _run_code exec(code, run_globals) File "/usr/local/lib/python3.10/dist-packages/fmpy/__main__.py", line 4, in main() File "/usr/local/lib/python3.10/dist-packages/fmpy/command_line.py", line 167, in main result = simulate_fmu(args.fmu_filename, File "/usr/local/lib/python3.10/dist-packages/fmpy/simulation.py", line 759, in simulate_fmu result = simulateME(model_description, fmu, start_time, stop_time, solver, step_size, relative_tolerance, start_values, apply_default_start_values, input, output, output_interval, record_events, timeout, step_finished, validate, set_stop_time) File "/usr/local/lib/python3.10/dist-packages/fmpy/simulation.py", line 1076, in simulateME step_event, _ = fmu.completedIntegratorStep() File "/usr/local/lib/python3.10/dist-packages/fmpy/fmi2.py", line 491, in completedIntegratorStep self.fmi2CompletedIntegratorStep(self.component, noSetFMUStatePriorToCurrentPoint, byref(enterEventMode), byref(terminateSimulation)) File "/usr/local/lib/python3.10/dist-packages/fmpy/fmi2.py", line 215, in w raise FMICallException(function=fname, status=res) fmpy.fmi1.FMICallException: fmi2CompletedIntegratorStep failed with status 3 (error).