Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr TransiEnt_TransiEnt.Components.Boundaries.Heat.Check.Test_Heatflow_L1_idContrQFlow.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.3-maint.9.1.x/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.3-maint.9.1.x/package.mo): time 2.652/2.652, allocations: 390.3 MB / 410.7 MB, free: 12.4 MB / 318.1 MB " [Timeout remaining time 177] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/DymolaCommands master/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/DymolaCommands master/package.mo): time 0.0007475/0.0007475, allocations: 34.06 kB / 0.4925 GB, free: 2.465 MB / 398.1 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/package.mo", uses=false) [Timeout 180] "[/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Control/PredictorModels_3508/Check/package.mo:2:1-21:10:writable] Warning: The package.order file contains a class TestReheater, which is expected to be stored in file TestReheater.mo, but seems to be named testReheater.mo. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Control/PredictorModels_3508/Check/testReheater.mo:2:1-117:17:writable] Warning: Expected the package to have name testReheater, but got TestReheater. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/package.mo:2:1-23:10:writable] Warning: PhysicalMills was referenced in the package.order file, but was not found in package.mo, PhysicalMills/package.mo or PhysicalMills.mo. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/package.mo:2:1-22:18:writable] Warning: Expected the package to have name physicalMills, but got PhysicalMills. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/package.mo:2:1-22:18:writable] Warning: The package.order file contains a class Mill_L4_advancedInit, which is expected to be stored in file Mill_L4_advancedInit.mo, but seems to be named mill_L4_advancedInit.mo. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/package.mo:2:1-22:18:writable] Warning: The package.order file contains a class Mill_L4, which is expected to be stored in file Mill_L4.mo, but seems to be named mill_L4.mo. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/mill_L4_advancedInit.mo:2:1-58:25:writable] Warning: Expected the package to have name mill_L4_advancedInit, but got Mill_L4_advancedInit. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/mill_L4_advancedInit.mo:2:1-58:25:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills; but got within ClaRa.Components.Mills.PhysicalMills; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/mill_L4.mo:2:1-315:12:writable] Warning: Expected the package to have name mill_L4, but got Mill_L4. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/mill_L4.mo:2:1-315:12:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills; but got within ClaRa.Components.Mills.PhysicalMills; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Check/package.mo:2:1-21:10:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills; but got within ClaRa.Components.Mills.PhysicalMills; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Check/package.mo:2:1-21:10:writable] Warning: The package.order file contains a class TestMillBox_2, which is expected to be stored in file TestMillBox_2.mo, but seems to be named testMillBox_2.mo. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Check/package.mo:2:1-21:10:writable] Warning: The package.order file contains a class TestMillBox_1_measurementInput, which is expected to be stored in file TestMillBox_1_measurementInput.mo, but seems to be named testMillBox_1_measurementInput.mo. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Check/package.mo:2:1-21:10:writable] Warning: The package.order file contains a class TestMillBox_1, which is expected to be stored in file TestMillBox_1.mo, but seems to be named testMillBox_1.mo. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Check/testMillBox_2.mo:2:1-297:18:writable] Warning: Expected the package to have name testMillBox_2, but got TestMillBox_2. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Check/testMillBox_2.mo:2:1-297:18:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Check; but got within ClaRa.Components.Mills.PhysicalMills.Check; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Check/testMillBox_1_measurementInput.mo:2:1-1342:35:writable] Warning: Expected the package to have name testMillBox_1_measurementInput, but got TestMillBox_1_measurementInput. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Check/testMillBox_1_measurementInput.mo:2:1-1342:35:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Check; but got within ClaRa.Components.Mills.PhysicalMills.Check; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Check/testMillBox_1.mo:2:1-465:18:writable] Warning: Expected the package to have name testMillBox_1, but got TestMillBox_1. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Check/testMillBox_1.mo:2:1-465:18:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Check; but got within ClaRa.Components.Mills.PhysicalMills.Check; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/package.mo:2:1-29:12:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills; but got within ClaRa.Components.Mills.PhysicalMills; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/FlowClassifier.mo:2:1-346:19:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes; but got within ClaRa.Components.Mills.PhysicalMills.Volumes; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/CentrifugalClassifier.mo:2:1-380:26:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes; but got within ClaRa.Components.Mills.PhysicalMills.Volumes; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/GrinderRingRoller.mo:2:1-294:22:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes; but got within ClaRa.Components.Mills.PhysicalMills.Volumes; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/FuelJoin_distributed.mo:2:1-133:25:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes; but got within ClaRa.Components.Mills.PhysicalMills.Volumes; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Dryer.mo:2:1-301:10:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes; but got within ClaRa.Components.Mills.PhysicalMills.Volumes; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/package.mo:2:1-20:17:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes; but got within ClaRa.Components.Mills.PhysicalMills.Volumes; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/package.mo:2:1-20:13:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Transport_Velocity/package.mo:2:1-20:23:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Transport_Velocity/Transport_complex.mo:2:1-71:22:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Transport_Velocity; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Transport_Velocity; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Transport_Velocity/Transport_constant.mo:2:1-49:23:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Transport_Velocity; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Transport_Velocity; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Transport_Velocity/Transport_base.mo:2:1-52:19:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Transport_Velocity; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Transport_Velocity; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Selection_Function/package.mo:2:1-20:23:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Selection_Function/Selection_Kersting.mo:2:1-80:23:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Selection_Function; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Selection_Function; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Selection_Function/Selection_Steinmetz.mo:2:1-104:24:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Selection_Function; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Selection_Function; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Selection_Function/Selection_constant.mo:2:1-45:23:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Selection_Function; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Selection_Function; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Selection_Function/Selection_base.mo:2:1-50:19:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Selection_Function; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Selection_Function; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Breakage_Function/package.mo:2:1-20:22:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Breakage_Function/Breakage_Austin.mo:2:1-109:20:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Breakage_Function; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Breakage_Function; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Breakage_Function/Breakage_Steinmetz.mo:2:1-106:23:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Breakage_Function; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Breakage_Function; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Breakage_Function/Breakage_constant.mo:2:1-45:22:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Breakage_Function; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Breakage_Function; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Breakage_Function/Breakage_base.mo:2:1-51:18:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Breakage_Function; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Breakage_Function; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Drying/package.mo:2:1-20:11:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Drying/Drying_ideal.mo:2:1-58:17:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Drying; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Drying; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Drying/Drying_base.mo:2:1-44:16:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Drying; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Drying; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Classifying/package.mo:2:1-20:16:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Classifying/Classifying_flow.mo:2:1-111:21:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Classifying; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Classifying; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Classifying/Classifying_centrifugal.mo:2:1-153:28:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Classifying; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Classifying; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Classifying/Classifying_centrifugal_base.mo:2:1-45:33:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Classifying; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Classifying; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Classifying/Classifying_flow_base.mo:2:1-45:26:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Classifying; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Classifying; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Records/package.mo:2:1-20:12:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Records/iCom_Dryer.mo:2:1-57:15:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Records; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Records; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Records/iCom_FlowClassifier.mo:2:1-67:24:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Records; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Records; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Records/iCom_CentrifugalClassifier.mo:2:1-69:31:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Records; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Records; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Records/iCom_Grinder.mo:2:1-61:17:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Records; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Records; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Records/FuelClassification_example_21classes.mo:2:1-43:41:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Records; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Records; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Records/GeometricProgression.mo:2:1-56:25:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Records; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Records; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Records/FuelClassification_generic.mo:2:1-43:31:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Records; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Records; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Records/FuelClassification_example_05classes.mo:2:1-43:41:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Records; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Records; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Records/FuelClassification_example_11classes.mo:2:1-43:41:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Records; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Records; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Records/FuelClassification_base.mo:2:1-61:28:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Records; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Records; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Check/package.mo:2:1-23:10:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes; but got within ClaRa.Components.Mills.PhysicalMills.Volumes; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Check/package.mo:2:1-23:10:writable] Warning: The package.order file contains a class TestFuelJoin, which is expected to be stored in file TestFuelJoin.mo, but seems to be named testFuelJoin.mo. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Check/package.mo:2:1-23:10:writable] Warning: The package.order file contains a class TestAerosolVolume, which is expected to be stored in file TestAerosolVolume.mo, but seems to be named testAerosolVolume.mo. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Check/package.mo:2:1-23:10:writable] Warning: The package.order file contains a class TestDryer, which is expected to be stored in file TestDryer.mo, but seems to be named testDryer.mo. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Check/package.mo:2:1-23:10:writable] Warning: The package.order file contains a class TestGrinder, which is expected to be stored in file TestGrinder.mo, but seems to be named testGrinder.mo. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Check/testFuelJoin.mo:2:1-93:17:writable] Warning: Expected the package to have name testFuelJoin, but got TestFuelJoin. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Check/testFuelJoin.mo:2:1-93:17:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Check; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Check; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Check/testAerosolVolume.mo:2:1-176:22:writable] Warning: Expected the package to have name testAerosolVolume, but got TestAerosolVolume. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Check/testAerosolVolume.mo:2:1-176:22:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Check; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Check; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Check/testDryer.mo:2:1-93:14:writable] Warning: Expected the package to have name testDryer, but got TestDryer. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Check/testDryer.mo:2:1-93:14:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Check; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Check; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Check/testGrinder.mo:2:1-154:16:writable] Warning: Expected the package to have name testGrinder, but got TestGrinder. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Check/testGrinder.mo:2:1-154:16:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Check; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Check; (ignoring the potential error; the class might have been inserted at an unexpected location). Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/package.mo): time 0.7556/0.7556, allocations: 127.2 MB / 0.7082 GB, free: 3.09 MB / 0.4981 GB " [Timeout remaining time 179] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.2-main/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.2-main/package.mo): time 0.1014/0.1014, allocations: 23.03 MB / 0.8477 GB, free: 13.3 MB / 0.5294 GB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaReference 4.0.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaReference 4.0.0+maint.om/package.mo): time 0.01599/0.01599, allocations: 0.8826 MB / 0.9718 GB, free: 14.09 MB / 0.6544 GB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_LinearSystems2 2.4.0/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_LinearSystems2 2.4.0/package.mo): time 0.2721/0.2721, allocations: 45.03 MB / 1.139 GB, free: 94.29 MB / 0.6544 GB " [Timeout remaining time 179] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_StateGraph2 2.1.0/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_StateGraph2 2.1.0/package.mo): time 0.09058/0.09058, allocations: 13.56 MB / 1.284 GB, free: 90.85 MB / 0.6544 GB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.001326/0.001326, allocations: 115.7 kB / 1.419 GB, free: 1.758 MB / 0.7013 GB " [Timeout remaining time 179] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.00144/0.00144, allocations: 189.5 kB / 1.555 GB, free: 229.2 MB / 0.8107 GB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.673/1.673, allocations: 222.9 MB / 1.907 GB, free: 71.38 MB / 0.8575 GB " [Timeout remaining time 178] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Design master/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Design master/package.mo): time 0.0007568/0.000757, allocations: 39.81 kB / 2.091 GB, free: 4.121 MB / 0.92 GB " [Timeout remaining time 179] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/DataFiles master/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/DataFiles master/package.mo): time 0.0006921/0.000692, allocations: 31.22 kB / 2.274 GB, free: 254.7 MB / 1.076 GB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/package.mo): time 1.215/1.215, allocations: 220.7 MB / 2.673 GB, free: 6.098 MB / 1.17 GB " [Timeout remaining time 177] Using package TransiEnt with version 2.0.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/package.mo) Using package DataFiles with version 0.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/DataFiles master/package.mo) Using package Design with version 0.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Design master/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Using package Modelica_StateGraph2 with version 2.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_StateGraph2 2.1.0/package.mo) Using package Modelica_LinearSystems2 with version 2.4.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_LinearSystems2 2.4.0/package.mo) Using package ModelicaReference with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaReference 4.0.0+maint.om/package.mo) Using package TILMedia with version 1.8.2 ClaRa (/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.2-main/package.mo) Using package ClaRa with version 1.8.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/package.mo) Using package DymolaCommands with version 0.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/DymolaCommands master/package.mo) Using package Buildings with version 9.1.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.3-maint.9.1.x/package.mo) Running command: translateModel(TransiEnt.Components.Boundaries.Heat.Check.Test_Heatflow_L1_idContrQFlow,tolerance=1e-06,outputFormat="empty",numberOfIntervals=2500,variableFilter="",fileNamePrefix="TransiEnt_TransiEnt.Components.Boundaries.Heat.Check.Test_Heatflow_L1_idContrQFlow") translateModel(TransiEnt.Components.Boundaries.Heat.Check.Test_Heatflow_L1_idContrQFlow,tolerance=1e-06,outputFormat="empty",numberOfIntervals=2500,variableFilter="",fileNamePrefix="TransiEnt_TransiEnt.Components.Boundaries.Heat.Check.Test_Heatflow_L1_idContrQFlow") [Timeout 660] "Warning: Requested package TILMedia of version 1.8.1 ClaRa, but this package was already loaded with version 1.8.2 ClaRa. OpenModelica cannot reason about compatibility between the two packages since they are not semantic versions. Warning: Requested package TILMedia of version 1.8.0 ClaRa, but this package was already loaded with version 1.8.2 ClaRa. OpenModelica cannot reason about compatibility between the two packages since they are not semantic versions. Warning: TransiEnt requested package ClaRa of version 1.8.0. ClaRa 1.8.1 is used instead which states that it is only compatible with a conversion script. Use convertPackageToLibrary(TransiEnt, ClaRa, \"1.8.1\") to run the conversion script or proceed with potential issues as a result. Notification: TransiEnt requested package Buildings of version 9.0.0. Buildings 9.1.3 is used instead which states that it is fully compatible without conversion script needed. Notification: Performance of FrontEnd - loaded program: time 0.00872/0.00872, allocations: 328.7 kB / 3.148 GB, free: 7.027 MB / 1.405 GB Notification: Performance of FrontEnd - Absyn->SCode: time 2.015/2.023, allocations: 229.7 MB / 3.373 GB, free: 51.3 MB / 1.499 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Boundaries/Heat/Base/Heatflow_L1_idContr_temp_base.mo:58:3-58:50:writable] Warning: An inner declaration for outer component modelStatistics could not be found and was automatically generated. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Boundaries/Heat/Base/Heatflow_L1_idContr_temp_base.mo:58:3-58:50:writable] Notification: The diagnostics message for the missing inner is: Your model is using an outer \"modelStatistics\" but it does not contain an inner \"modelStatistics\" component. Drag model TransiEnt.ModelStatistics into your model to make it work. Notification: Performance of NFInst.instantiate(TransiEnt.Components.Boundaries.Heat.Check.Test_Heatflow_L1_idContrQFlow): time 0.04538/2.069, allocations: 36.92 MB / 3.409 GB, free: 33.03 MB / 1.499 GB Notification: Performance of NFInst.instExpressions: time 0.01674/2.086, allocations: 11.57 MB / 3.42 GB, free: 24.69 MB / 1.499 GB Notification: Performance of NFInst.updateImplicitVariability: time 0.003472/2.089, allocations: 62.28 kB / 3.42 GB, free: 24.67 MB / 1.499 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/SimCenter.mo:69:5-70:35:writable] Warning: Connector cycleSumPort is not balanced: The number of potential variables (0) is not equal to the number of flow variables (4). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Statistics/Collectors/LocalCollectors/CollectHeatingPower.mo:68:3-68:143:writable] Warning: Connector heatFlowCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/ModelStatistics.mo:85:3-85:105:writable] Warning: Connector powerCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/ModelStatistics.mo:86:3-86:112:writable] Warning: Connector primBalPowerCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/ModelStatistics.mo:87:3-87:102:writable] Warning: Connector primBalPowerOfferCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/ModelStatistics.mo:88:3-88:111:writable] Warning: Connector secBalPowerCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/ModelStatistics.mo:89:3-89:101:writable] Warning: Connector secBalPowerOfferCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/ModelStatistics.mo:90:3-90:92:writable] Warning: Connector surroundingGridLoad is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/ModelStatistics.mo:92:3-92:126:writable] Warning: Connector tielinePowerCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/ModelStatistics.mo:93:3-93:130:writable] Warning: Connector tielineSetPowerCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/ModelStatistics.mo:95:3-95:95:writable] Warning: Connector kineticEnergyCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/ModelStatistics.mo:98:3-98:99:writable] Warning: Connector gwpCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/ModelStatistics.mo:100:3-100:107:writable] Warning: Connector gwpCollectorHeat is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/ModelStatistics.mo:103:3-103:82:writable] Warning: Connector heatFlowCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/ModelStatistics.mo:105:3-105:87:writable] Warning: Connector costsCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (6). Notification: Performance of NFTyping.typeComponents: time 0.00556/2.095, allocations: 1.865 MB / 3.422 GB, free: 23.75 MB / 1.499 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Basics/Functions/fullPathName.mo:2:1-78:17:writable] Warning: Pure function 'TransiEnt.Basics.Functions.fullPathName' contains a call to impure function 'Modelica.Utilities.Streams.print'. Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.BrownCoal as Integer: 1. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.BrownCoal) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.BlackCoal as Integer: 2. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.BlackCoal) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.NaturalGas as Integer: 3. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.NaturalGas) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.WindOnshore as Integer: 4. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.WindOnshore) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.WindOffshore as Integer: 5. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.WindOffshore) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.Solar as Integer: 6. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.Solar) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.Hydro as Integer: 7. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.Hydro) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.Nuclear as Integer: 8. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.Nuclear) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.Oil as Integer: 9. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.Oil) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.NaturalGas as Integer: 3. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.NaturalGas) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.DistrictHeating as Integer: 4. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.DistrictHeating) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.Oil as Integer: 5. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.Oil) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.Electricity as Integer: 6. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.Electricity) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.Solar as Integer: 7. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.Solar) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.Biomass as Integer: 8. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.Biomass) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.Others as Integer: 10. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.Others) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Consumer as Integer: 1. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Consumer) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Conventional as Integer: 2. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Conventional) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Cogeneration as Integer: 3. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Cogeneration) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Renewable as Integer: 4. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Renewable) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Consumer as Integer: 1. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Consumer) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Generic as Integer: 6. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Generic) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Consumer as Integer: 1. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Consumer) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Renewable as Integer: 4. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Renewable) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Cogeneration as Integer: 3. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Cogeneration) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Conventional as Integer: 2. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Conventional) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Cogeneration as Integer: 3. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Cogeneration) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Conventional as Integer: 2. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Conventional) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Storage as Integer: 5. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Storage) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Consumer as Integer: 1. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Consumer) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Conventional as Integer: 2. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Conventional) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Cogeneration as Integer: 3. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Cogeneration) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Renewable as Integer: 4. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Renewable) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Generic as Integer: 6. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Generic) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Consumer as Integer: 1. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Consumer) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Conventional as Integer: 2. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Conventional) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Cogeneration as Integer: 3. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Cogeneration) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Renewable as Integer: 4. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Renewable) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Generic as Integer: 6. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Generic) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Consumer as Integer: 1. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Consumer) instead! Notification: Performance of NFTyping.typeBindings: time 0.005549/2.1, allocations: 1.884 MB / 3.424 GB, free: 22.66 MB / 1.499 GB Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Consumer as Integer: 1. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Consumer) instead! Notification: Performance of NFTyping.typeClassSections: time 0.004037/2.104, allocations: 1.445 MB / 3.425 GB, free: 21.86 MB / 1.499 GB Notification: Performance of NFFlatten.flatten: time 0.00742/2.112, allocations: 4.709 MB / 3.43 GB, free: 19.57 MB / 1.499 GB Notification: Performance of NFFlatten.resolveConnections: time 0.003373/2.115, allocations: 1.879 MB / 3.432 GB, free: 18.74 MB / 1.499 GB Notification: Performance of NFEvalConstants.evaluate: time 0.004018/2.119, allocations: 2.086 MB / 3.434 GB, free: 17.89 MB / 1.499 GB Notification: Performance of NFSimplifyModel.simplify: time 0.003621/2.123, allocations: 2.196 MB / 3.436 GB, free: 16.86 MB / 1.499 GB Notification: Performance of NFPackage.collectConstants: time 0.001381/2.124, allocations: 354.2 kB / 3.436 GB, free: 16.86 MB / 1.499 GB Notification: Performance of NFFlatten.collectFunctions: time 0.003108/2.127, allocations: 0.9568 MB / 3.437 GB, free: 16.62 MB / 1.499 GB Notification: Performance of NFScalarize.scalarize: time 0.002015/2.129, allocations: 1.476 MB / 3.438 GB, free: 15.93 MB / 1.499 GB Notification: Performance of NFVerifyModel.verify: time 0.004238/2.134, allocations: 2.381 MB / 3.441 GB, free: 14.29 MB / 1.499 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Statistics/Collectors/GlobalCollectors/GwpEmissionsStatistics.mo:79:53-79:84:writable] Error: Variable simCenter.expertMode not found in scope GwpEmissionsStatistics. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Statistics/Collectors/GlobalCollectors/GwpEmissionsStatistics.mo:83:53-83:84:writable] Error: Variable simCenter.expertMode not found in scope GwpEmissionsStatistics. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Statistics/Collectors/GlobalCollectors/EconomicStatistics.mo:42:70-42:85:writable] Error: Variable True not found in scope EconomicStatistics. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/ModelStatistics.mo:105:71-105:86:writable] Error: Variable True not found in scope ModelStatistics. Notification: Performance of NFConvertDAE.convert: time 0.01769/2.151, allocations: 6.699 MB / 3.447 GB, free: 11.46 MB / 1.499 GB Notification: Performance of FrontEnd - DAE generated: time 6.432e-06/2.151, allocations: 1.125 kB / 3.447 GB, free: 11.46 MB / 1.499 GB Notification: Performance of FrontEnd: time 2.014e-06/2.151, allocations: 0 / 3.447 GB, free: 11.46 MB / 1.499 GB Notification: Performance of Transformations before backend: time 0.0002825/2.152, allocations: 0 / 3.447 GB, free: 11.46 MB / 1.499 GB Notification: Model statistics after passing the front-end and creating the data structures used by the back-end: * Number of equations: 699 * Number of variables: 699 Notification: Performance of Generate backend data structure: time 0.01476/2.167, allocations: 5.939 MB / 3.453 GB, free: 7.719 MB / 1.499 GB Notification: Performance of prepare preOptimizeDAE: time 4.561e-05/2.167, allocations: 9.312 kB / 3.453 GB, free: 7.719 MB / 1.499 GB Notification: Performance of preOpt normalInlineFunction (simulation): time 0.002109/2.169, allocations: 0.6632 MB / 3.454 GB, free: 7.379 MB / 1.499 GB Notification: Performance of preOpt evaluateParameters (simulation): time 0.01072/2.179, allocations: 5.568 MB / 3.459 GB, free: 4.645 MB / 1.499 GB Notification: Performance of preOpt simplifyIfEquations (simulation): time 0.0001852/2.18, allocations: 198.9 kB / 3.459 GB, free: 4.531 MB / 1.499 GB Notification: Performance of preOpt expandDerOperator (simulation): time 0.0003461/2.18, allocations: 218.8 kB / 3.46 GB, free: 4.461 MB / 1.499 GB Notification: Performance of preOpt clockPartitioning (simulation): time 0.004658/2.185, allocations: 3.45 MB / 3.463 GB, free: 1.984 MB / 1.499 GB Notification: Performance of preOpt findStateOrder (simulation): time 9.07e-05/2.185, allocations: 25.59 kB / 3.463 GB, free: 1.969 MB / 1.499 GB Notification: Performance of preOpt replaceEdgeChange (simulation): time 0.0002095/2.185, allocations: 110.8 kB / 3.463 GB, free: 1.895 MB / 1.499 GB Notification: Performance of preOpt inlineArrayEqn (simulation): time 7.908e-05/2.185, allocations: 70.44 kB / 3.463 GB, free: 1.895 MB / 1.499 GB Notification: Performance of preOpt removeEqualRHS (simulation): time 0.003906/2.189, allocations: 2.253 MB / 3.465 GB, free: 1.055 MB / 1.499 GB Notification: Performance of preOpt removeSimpleEquations (simulation): time 0.02255/2.212, allocations: 19.65 MB / 3.485 GB, free: 464 kB / 1.514 GB Notification: Performance of preOpt comSubExp (simulation): time 0.001611/2.213, allocations: 0.6932 MB / 3.485 GB, free: 15.96 MB / 1.53 GB Notification: Performance of preOpt resolveLoops (simulation): time 0.0008101/2.214, allocations: 465 kB / 3.486 GB, free: 15.68 MB / 1.53 GB Notification: Performance of preOpt evalFunc (simulation): time 0.0001606/2.214, allocations: 45.53 kB / 3.486 GB, free: 15.67 MB / 1.53 GB Notification: Performance of preOpt encapsulateWhenConditions (simulation): time 0.001237/2.215, allocations: 0.751 MB / 3.486 GB, free: 15.13 MB / 1.53 GB Notification: Performance of pre-optimization done (n=193): time 3.867e-06/2.215, allocations: 1.406 kB / 3.486 GB, free: 15.13 MB / 1.53 GB Notification: Performance of matching and sorting (n=193): time 0.004393/2.22, allocations: 1.848 MB / 3.488 GB, free: 14.29 MB / 1.53 GB Notification: Performance of inlineWhenForInitialization (initialization): time 0.0005584/2.22, allocations: 0.992 MB / 3.489 GB, free: 13.09 MB / 1.53 GB Notification: Performance of selectInitializationVariablesDAE (initialization): time 0.0096/2.23, allocations: 5.369 MB / 3.494 GB, free: 11.21 MB / 1.53 GB Notification: Performance of collectPreVariables (initialization): time 0.0002449/2.23, allocations: 45.02 kB / 3.494 GB, free: 11.16 MB / 1.53 GB Notification: Performance of collectInitialEqns (initialization): time 0.00264/2.233, allocations: 2.556 MB / 3.497 GB, free: 9.109 MB / 1.53 GB Notification: Performance of collectInitialBindings (initialization): time 0.0009027/2.234, allocations: 0.6891 MB / 3.498 GB, free: 8.566 MB / 1.53 GB Notification: Performance of simplifyInitialFunctions (initialization): time 0.001211/2.235, allocations: 0.7996 MB / 3.498 GB, free: 8.148 MB / 1.53 GB Notification: Performance of setup shared object (initialization): time 0.0001287/2.235, allocations: 302.8 kB / 3.499 GB, free: 7.852 MB / 1.53 GB Notification: Performance of preBalanceInitialSystem (initialization): time 0.001611/2.237, allocations: 0.8744 MB / 3.5 GB, free: 7.535 MB / 1.53 GB Notification: Performance of partitionIndependentBlocks (initialization): time 0.003435/2.24, allocations: 3.021 MB / 3.503 GB, free: 4.246 MB / 1.53 GB Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.heatingPower.E[6] = $START.modelStatistics.heatingPower.E[6] (0.0 = $START.modelStatistics.heatingPower.E[6]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.heatingPower.E[4] = $START.modelStatistics.heatingPower.E[4] (0.0 = $START.modelStatistics.heatingPower.E[4]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.heatingPower.E[3] = $START.modelStatistics.heatingPower.E[3] (0.0 = $START.modelStatistics.heatingPower.E[3]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.heatingPower.E[2] = $START.modelStatistics.heatingPower.E[2] (0.0 = $START.modelStatistics.heatingPower.E[2]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.heatingPower.E[1] = $START.modelStatistics.heatingPower.E[1] (0.0 = $START.modelStatistics.heatingPower.E[1]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.heatingPower.E[5] = $START.modelStatistics.heatingPower.E[5] (0.0 = $START.modelStatistics.heatingPower.E[5]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negPBE[6] = $START.modelStatistics.electricPower.negPBE[6] (0.0 = $START.modelStatistics.electricPower.negPBE[6]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negPBE[5] = $START.modelStatistics.electricPower.negPBE[5] (0.0 = $START.modelStatistics.electricPower.negPBE[5]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negPBE[4] = $START.modelStatistics.electricPower.negPBE[4] (0.0 = $START.modelStatistics.electricPower.negPBE[4]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negPBE[3] = $START.modelStatistics.electricPower.negPBE[3] (0.0 = $START.modelStatistics.electricPower.negPBE[3]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negPBE[2] = $START.modelStatistics.electricPower.negPBE[2] (0.0 = $START.modelStatistics.electricPower.negPBE[2]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negPBE[1] = $START.modelStatistics.electricPower.negPBE[1] (0.0 = $START.modelStatistics.electricPower.negPBE[1]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posPBE[6] = $START.modelStatistics.electricPower.posPBE[6] (0.0 = $START.modelStatistics.electricPower.posPBE[6]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posPBE[5] = $START.modelStatistics.electricPower.posPBE[5] (0.0 = $START.modelStatistics.electricPower.posPBE[5]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posPBE[4] = $START.modelStatistics.electricPower.posPBE[4] (0.0 = $START.modelStatistics.electricPower.posPBE[4]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posPBE[3] = $START.modelStatistics.electricPower.posPBE[3] (0.0 = $START.modelStatistics.electricPower.posPBE[3]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posPBE[2] = $START.modelStatistics.electricPower.posPBE[2] (0.0 = $START.modelStatistics.electricPower.posPBE[2]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posPBE[1] = $START.modelStatistics.electricPower.posPBE[1] (0.0 = $START.modelStatistics.electricPower.posPBE[1]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.E[4] = $START.modelStatistics.electricPower.E[4] (0.0 = $START.modelStatistics.electricPower.E[4]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.E[3] = $START.modelStatistics.electricPower.E[3] (0.0 = $START.modelStatistics.electricPower.E[3]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.E[2] = $START.modelStatistics.electricPower.E[2] (0.0 = $START.modelStatistics.electricPower.E[2]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.E[1] = $START.modelStatistics.electricPower.E[1] (0.0 = $START.modelStatistics.electricPower.E[1]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.E[6] = $START.modelStatistics.electricPower.E[6] (0.0 = $START.modelStatistics.electricPower.E[6]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.E[5] = $START.modelStatistics.electricPower.E[5] (0.0 = $START.modelStatistics.electricPower.E[5]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE_heat[10] = $START.modelStatistics.gwpEmissions.m_CDE_heat[10] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE_heat[10]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE_heat[8] = $START.modelStatistics.gwpEmissions.m_CDE_heat[8] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE_heat[8]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE_heat[7] = $START.modelStatistics.gwpEmissions.m_CDE_heat[7] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE_heat[7]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE_heat[6] = $START.modelStatistics.gwpEmissions.m_CDE_heat[6] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE_heat[6]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE_heat[5] = $START.modelStatistics.gwpEmissions.m_CDE_heat[5] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE_heat[5]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE_heat[4] = $START.modelStatistics.gwpEmissions.m_CDE_heat[4] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE_heat[4]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE_heat[3] = $START.modelStatistics.gwpEmissions.m_CDE_heat[3] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE_heat[3]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[9] = $START.modelStatistics.gwpEmissions.m_CDE[9] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[9]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[8] = $START.modelStatistics.gwpEmissions.m_CDE[8] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[8]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[7] = $START.modelStatistics.gwpEmissions.m_CDE[7] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[7]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[6] = $START.modelStatistics.gwpEmissions.m_CDE[6] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[6]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[5] = $START.modelStatistics.gwpEmissions.m_CDE[5] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[5]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[4] = $START.modelStatistics.gwpEmissions.m_CDE[4] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[4]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[3] = $START.modelStatistics.gwpEmissions.m_CDE[3] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[3]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[2] = $START.modelStatistics.gwpEmissions.m_CDE[2] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[2]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[1] = $START.modelStatistics.gwpEmissions.m_CDE[1] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[1]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE_heat[9] = $START.modelStatistics.gwpEmissions.m_CDE_heat[9] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE_heat[9]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE_heat[2] = $START.modelStatistics.gwpEmissions.m_CDE_heat[2] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE_heat[2]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE_heat[1] = $START.modelStatistics.gwpEmissions.m_CDE_heat[1] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE_heat[1]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[14] = $START.modelStatistics.gwpEmissions.m_CDE[14] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[14]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[13] = $START.modelStatistics.gwpEmissions.m_CDE[13] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[13]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[12] = $START.modelStatistics.gwpEmissions.m_CDE[12] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[12]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[11] = $START.modelStatistics.gwpEmissions.m_CDE[11] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[11]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[10] = $START.modelStatistics.gwpEmissions.m_CDE[10] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[10]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negSBE[6] = $START.modelStatistics.electricPower.negSBE[6] (0.0 = $START.modelStatistics.electricPower.negSBE[6]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negSBE[5] = $START.modelStatistics.electricPower.negSBE[5] (0.0 = $START.modelStatistics.electricPower.negSBE[5]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negSBE[4] = $START.modelStatistics.electricPower.negSBE[4] (0.0 = $START.modelStatistics.electricPower.negSBE[4]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negSBE[3] = $START.modelStatistics.electricPower.negSBE[3] (0.0 = $START.modelStatistics.electricPower.negSBE[3]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negSBE[2] = $START.modelStatistics.electricPower.negSBE[2] (0.0 = $START.modelStatistics.electricPower.negSBE[2]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negSBE[1] = $START.modelStatistics.electricPower.negSBE[1] (0.0 = $START.modelStatistics.electricPower.negSBE[1]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posSBE[6] = $START.modelStatistics.electricPower.posSBE[6] (0.0 = $START.modelStatistics.electricPower.posSBE[6]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posSBE[5] = $START.modelStatistics.electricPower.posSBE[5] (0.0 = $START.modelStatistics.electricPower.posSBE[5]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posSBE[4] = $START.modelStatistics.electricPower.posSBE[4] (0.0 = $START.modelStatistics.electricPower.posSBE[4]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posSBE[3] = $START.modelStatistics.electricPower.posSBE[3] (0.0 = $START.modelStatistics.electricPower.posSBE[3]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posSBE[2] = $START.modelStatistics.electricPower.posSBE[2] (0.0 = $START.modelStatistics.electricPower.posSBE[2]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posSBE[1] = $START.modelStatistics.electricPower.posSBE[1] (0.0 = $START.modelStatistics.electricPower.posSBE[1]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.E_residual_pos = $START.modelStatistics.electricPower.E_residual_pos (0.0 = $START.modelStatistics.electricPower.E_residual_pos) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.E_residual_neg = $START.modelStatistics.electricPower.E_residual_neg (0.0 = $START.modelStatistics.electricPower.E_residual_neg) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: heatflow_L1_idContrQFlow_tempVar.collectHeatingPower.E = $START.heatflow_L1_idContrQFlow_tempVar.collectHeatingPower.E (0.0 = $START.heatflow_L1_idContrQFlow_tempVar.collectHeatingPower.E) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: heatflow_L1_idContrQFlow_tempConst.collectHeatingPower.E = $START.heatflow_L1_idContrQFlow_tempConst.collectHeatingPower.E (0.0 = $START.heatflow_L1_idContrQFlow_tempConst.collectHeatingPower.E) Notification: Performance of analyzeInitialSystem (initialization): time 0.01083/2.251, allocations: 10.11 MB / 3.512 GB, free: 9.98 MB / 1.545 GB Notification: Performance of solveInitialSystemEqSystem (initialization): time 0.0001139/2.251, allocations: 21.75 kB / 3.512 GB, free: 9.98 MB / 1.545 GB Notification: Performance of matching and sorting (n=512) (initialization): time 0.00842/2.26, allocations: 3.648 MB / 3.516 GB, free: 8.402 MB / 1.545 GB Notification: Performance of prepare postOptimizeDAE: time 6.661e-05/2.26, allocations: 37.8 kB / 3.516 GB, free: 8.402 MB / 1.545 GB Notification: Performance of postOpt simplifyComplexFunction (initialization): time 0.0002128/2.26, allocations: 126.1 kB / 3.516 GB, free: 8.402 MB / 1.545 GB Notification: Performance of postOpt tearingSystem (initialization): time 0.0001102/2.26, allocations: 98.16 kB / 3.516 GB, free: 8.402 MB / 1.545 GB Notification: Performance of postOpt solveSimpleEquations (initialization): time 0.001839/2.262, allocations: 0.6837 MB / 3.517 GB, free: 8.312 MB / 1.545 GB Notification: Performance of postOpt calculateStrongComponentJacobians (initialization): time 0.0001366/2.262, allocations: 156.4 kB / 3.517 GB, free: 8.27 MB / 1.545 GB Notification: Performance of postOpt simplifyAllExpressions (initialization): time 0.003592/2.266, allocations: 485.7 kB / 3.518 GB, free: 7.953 MB / 1.545 GB Notification: Performance of postOpt collapseArrayExpressions (initialization): time 0.0003727/2.266, allocations: 207.2 kB / 3.518 GB, free: 7.93 MB / 1.545 GB Warning: The initial conditions are over specified. The following 64 initial equations are redundant, so they are removed from the initialization system: modelStatistics.heatingPower.E[6] = $START.modelStatistics.heatingPower.E[6] modelStatistics.heatingPower.E[4] = $START.modelStatistics.heatingPower.E[4] modelStatistics.heatingPower.E[3] = $START.modelStatistics.heatingPower.E[3] modelStatistics.heatingPower.E[2] = $START.modelStatistics.heatingPower.E[2] modelStatistics.heatingPower.E[1] = $START.modelStatistics.heatingPower.E[1] modelStatistics.heatingPower.E[5] = $START.modelStatistics.heatingPower.E[5] modelStatistics.electricPower.negPBE[6] = $START.modelStatistics.electricPower.negPBE[6] modelStatistics.electricPower.negPBE[5] = $START.modelStatistics.electricPower.negPBE[5] modelStatistics.electricPower.negPBE[4] = $START.modelStatistics.electricPower.negPBE[4] modelStatistics.electricPower.negPBE[3] = $START.modelStatistics.electricPower.negPBE[3] modelStatistics.electricPower.negPBE[2] = $START.modelStatistics.electricPower.negPBE[2] modelStatistics.electricPower.negPBE[1] = $START.modelStatistics.electricPower.negPBE[1] modelStatistics.electricPower.posPBE[6] = $START.modelStatistics.electricPower.posPBE[6] modelStatistics.electricPower.posPBE[5] = $START.modelStatistics.electricPower.posPBE[5] modelStatistics.electricPower.posPBE[4] = $START.modelStatistics.electricPower.posPBE[4] modelStatistics.electricPower.posPBE[3] = $START.modelStatistics.electricPower.posPBE[3] modelStatistics.electricPower.posPBE[2] = $START.modelStatistics.electricPower.posPBE[2] modelStatistics.electricPower.posPBE[1] = $START.modelStatistics.electricPower.posPBE[1] modelStatistics.electricPower.E[4] = $START.modelStatistics.electricPower.E[4] modelStatistics.electricPower.E[3] = $START.modelStatistics.electricPower.E[3] modelStatistics.electricPower.E[2] = $START.modelStatistics.electricPower.E[2] modelStatistics.electricPower.E[1] = $START.modelStatistics.electricPower.E[1] modelStatistics.electricPower.E[6] = $START.modelStatistics.electricPower.E[6] modelStatistics.electricPower.E[5] = $START.modelStatistics.electricPower.E[5] modelStatistics.gwpEmissions.m_CDE_heat[10] = $START.modelStatistics.gwpEmissions.m_CDE_heat[10] modelStatistics.gwpEmissions.m_CDE_heat[8] = $START.modelStatistics.gwpEmissions.m_CDE_heat[8] modelStatistics.gwpEmissions.m_CDE_heat[7] = $START.modelStatistics.gwpEmissions.m_CDE_heat[7] modelStatistics.gwpEmissions.m_CDE_heat[6] = $START.modelStatistics.gwpEmissions.m_CDE_heat[6] modelStatistics.gwpEmissions.m_CDE_heat[5] = $START.modelStatistics.gwpEmissions.m_CDE_heat[5] modelStatistics.gwpEmissions.m_CDE_heat[4] = $START.modelStatistics.gwpEmissions.m_CDE_heat[4] modelStatistics.gwpEmissions.m_CDE_heat[3] = $START.modelStatistics.gwpEmissions.m_CDE_heat[3] modelStatistics.gwpEmissions.m_CDE[9] = $START.modelStatistics.gwpEmissions.m_CDE[9] modelStatistics.gwpEmissions.m_CDE[8] = $START.modelStatistics.gwpEmissions.m_CDE[8] modelStatistics.gwpEmissions.m_CDE[7] = $START.modelStatistics.gwpEmissions.m_CDE[7] modelStatistics.gwpEmissions.m_CDE[6] = $START.modelStatistics.gwpEmissions.m_CDE[6] modelStatistics.gwpEmissions.m_CDE[5] = $START.modelStatistics.gwpEmissions.m_CDE[5] modelStatistics.gwpEmissions.m_CDE[4] = $START.modelStatistics.gwpEmissions.m_CDE[4] modelStatistics.gwpEmissions.m_CDE[3] = $START.modelStatistics.gwpEmissions.m_CDE[3] modelStatistics.gwpEmissions.m_CDE[2] = $START.modelStatistics.gwpEmissions.m_CDE[2] modelStatistics.gwpEmissions.m_CDE[1] = $START.modelStatistics.gwpEmissions.m_CDE[1] modelStatistics.gwpEmissions.m_CDE_heat[9] = $START.modelStatistics.gwpEmissions.m_CDE_heat[9] modelStatistics.gwpEmissions.m_CDE_heat[2] = $START.modelStatistics.gwpEmissions.m_CDE_heat[2] modelStatistics.gwpEmissions.m_CDE_heat[1] = $START.modelStatistics.gwpEmissions.m_CDE_heat[1] modelStatistics.gwpEmissions.m_CDE[14] = $START.modelStatistics.gwpEmissions.m_CDE[14] modelStatistics.gwpEmissions.m_CDE[13] = $START.modelStatistics.gwpEmissions.m_CDE[13] modelStatistics.gwpEmissions.m_CDE[12] = $START.modelStatistics.gwpEmissions.m_CDE[12] modelStatistics.gwpEmissions.m_CDE[11] = $START.modelStatistics.gwpEmissions.m_CDE[11] modelStatistics.gwpEmissions.m_CDE[10] = $START.modelStatistics.gwpEmissions.m_CDE[10] modelStatistics.electricPower.negSBE[6] = $START.modelStatistics.electricPower.negSBE[6] modelStatistics.electricPower.negSBE[5] = $START.modelStatistics.electricPower.negSBE[5] modelStatistics.electricPower.negSBE[4] = $START.modelStatistics.electricPower.negSBE[4] modelStatistics.electricPower.negSBE[3] = $START.modelStatistics.electricPower.negSBE[3] modelStatistics.electricPower.negSBE[2] = $START.modelStatistics.electricPower.negSBE[2] modelStatistics.electricPower.negSBE[1] = $START.modelStatistics.electricPower.negSBE[1] modelStatistics.electricPower.posSBE[6] = $START.modelStatistics.electricPower.posSBE[6] modelStatistics.electricPower.posSBE[5] = $START.modelStatistics.electricPower.posSBE[5] modelStatistics.electricPower.posSBE[4] = $START.modelStatistics.electricPower.posSBE[4] modelStatistics.electricPower.posSBE[3] = $START.modelStatistics.electricPower.posSBE[3] modelStatistics.electricPower.posSBE[2] = $START.modelStatistics.electricPower.posSBE[2] modelStatistics.electricPower.posSBE[1] = $START.modelStatistics.electricPower.posSBE[1] modelStatistics.electricPower.E_residual_pos = $START.modelStatistics.electricPower.E_residual_pos modelStatistics.electricPower.E_residual_neg = $START.modelStatistics.electricPower.E_residual_neg heatflow_L1_idContrQFlow_tempVar.collectHeatingPower.E = $START.heatflow_L1_idContrQFlow_tempVar.collectHeatingPower.E heatflow_L1_idContrQFlow_tempConst.collectHeatingPower.E = $START.heatflow_L1_idContrQFlow_tempConst.collectHeatingPower.E. Notification: Model statistics after passing the back-end for initialization: * Number of independent subsystems: 341 * Number of states: 0 () * Number of discrete variables: 10 ($PRE.simCenter.Variable_Ground_Temperature.MSL_combiTimeTable.nextTimeEvent,$whenCondition2,simCenter.Variable_Ground_Temperature.MSL_combiTimeTable.nextTimeEventScaled,$PRE.simCenter.Variable_Ground_Temperature.MSL_combiTimeTable.nextTimeEventScaled,simCenter.Variable_Ground_Temperature.MSL_combiTimeTable.nextTimeEvent,$PRE.simCenter.electricityPrice.MSL_combiTimeTable.nextTimeEvent,$whenCondition1,simCenter.electricityPrice.MSL_combiTimeTable.nextTimeEventScaled,$PRE.simCenter.electricityPrice.MSL_combiTimeTable.nextTimeEventScaled,simCenter.electricityPrice.MSL_combiTimeTable.nextTimeEvent) * Number of discrete states: 0 () * Number of clocked states: 0 () * Top-level inputs: 0 Notification: Strong component statistics for initialization (386): * Single equations (assignments): 368 * Array equations: 0 * Algorithm blocks: 0 * Record equations: 18 * When equations: 0 * If-equations: 0 * Equation systems (not torn): 0 * Torn equation systems: 0 * Mixed (continuous/discrete) equation systems: 0 Notification: Performance of prepare postOptimizeDAE: time 0.003362/2.269, allocations: 1.801 MB / 3.519 GB, free: 6.945 MB / 1.545 GB Notification: Performance of postOpt lateInlineFunction (simulation): time 0.001357/2.271, allocations: 0.5459 MB / 3.52 GB, free: 6.629 MB / 1.545 GB Notification: Performance of postOpt wrapFunctionCalls (simulation): time 0.001257/2.272, allocations: 0.544 MB / 3.521 GB, free: 6.426 MB / 1.545 GB Notification: Performance of postOpt inlineArrayEqn (simulation): time 2.587e-05/2.272, allocations: 19.91 kB / 3.521 GB, free: 6.426 MB / 1.545 GB Notification: Performance of postOpt constantLinearSystem (simulation): time 2.086e-05/2.272, allocations: 18.47 kB / 3.521 GB, free: 6.418 MB / 1.545 GB Notification: Performance of postOpt simplifysemiLinear (simulation): time 1.619e-05/2.272, allocations: 10.81 kB / 3.521 GB, free: 6.418 MB / 1.545 GB Notification: Performance of postOpt removeSimpleEquations (simulation): time 0.005118/2.277, allocations: 2.563 MB / 3.523 GB, free: 5.324 MB / 1.545 GB Notification: Performance of postOpt simplifyComplexFunction (simulation): time 0.0001166/2.277, allocations: 59.22 kB / 3.523 GB, free: 5.324 MB / 1.545 GB Notification: Performance of postOpt solveSimpleEquations (simulation): time 0.0003561/2.278, allocations: 97.72 kB / 3.523 GB, free: 5.312 MB / 1.545 GB Notification: Performance of postOpt tearingSystem (simulation): time 1.284e-05/2.278, allocations: 10.38 kB / 3.523 GB, free: 5.312 MB / 1.545 GB Notification: Performance of postOpt inputDerivativesUsed (simulation): time 8.345e-05/2.278, allocations: 36.11 kB / 3.523 GB, free: 5.305 MB / 1.545 GB Notification: Performance of postOpt calculateStrongComponentJacobians (simulation): time 1.558e-05/2.278, allocations: 15.81 kB / 3.523 GB, free: 5.301 MB / 1.545 GB Notification: Performance of postOpt calculateStateSetsJacobians (simulation): time 1.477e-05/2.278, allocations: 20.81 kB / 3.523 GB, free: 5.289 MB / 1.545 GB Notification: Performance of postOpt symbolicJacobian (simulation): time 0.003325/2.281, allocations: 1.695 MB / 3.525 GB, free: 4.246 MB / 1.545 GB Notification: Performance of postOpt removeConstants (simulation): time 0.002172/2.283, allocations: 0.9441 MB / 3.526 GB, free: 3.641 MB / 1.545 GB Notification: Performance of postOpt simplifyTimeIndepFuncCalls (simulation): time 0.0005574/2.284, allocations: 23.81 kB / 3.526 GB, free: 3.633 MB / 1.545 GB Notification: Performance of postOpt simplifyAllExpressions (simulation): time 0.0009318/2.285, allocations: 35.95 kB / 3.526 GB, free: 3.617 MB / 1.545 GB Notification: Performance of postOpt findZeroCrossings (simulation): time 0.0001794/2.285, allocations: 80.67 kB / 3.526 GB, free: 3.594 MB / 1.545 GB Notification: Performance of postOpt collapseArrayExpressions (simulation): time 9.642e-05/2.285, allocations: 43.95 kB / 3.526 GB, free: 3.59 MB / 1.545 GB Notification: Performance of sorting global known variables: time 0.007193/2.292, allocations: 3.544 MB / 3.53 GB, free: 2.398 MB / 1.545 GB Notification: Performance of sort global known variables: time 4.71e-07/2.293, allocations: 0 / 3.53 GB, free: 2.398 MB / 1.545 GB Notification: Performance of remove unused functions: time 0.004787/2.297, allocations: 0.8591 MB / 3.53 GB, free: 2.227 MB / 1.545 GB Notification: Model statistics after passing the back-end for simulation: * Number of independent subsystems: 33 * Number of states: 0 () * Number of discrete variables: 6 ($whenCondition2,simCenter.Variable_Ground_Temperature.MSL_combiTimeTable.nextTimeEvent,simCenter.Variable_Ground_Temperature.MSL_combiTimeTable.nextTimeEventScaled,$whenCondition1,simCenter.electricityPrice.MSL_combiTimeTable.nextTimeEvent,simCenter.electricityPrice.MSL_combiTimeTable.nextTimeEventScaled) * Number of discrete states: 4 (simCenter.electricityPrice.MSL_combiTimeTable.nextTimeEventScaled,simCenter.electricityPrice.MSL_combiTimeTable.nextTimeEvent,simCenter.Variable_Ground_Temperature.MSL_combiTimeTable.nextTimeEventScaled,simCenter.Variable_Ground_Temperature.MSL_combiTimeTable.nextTimeEvent) * Number of clocked states: 0 () * Top-level inputs: 0 Notification: Strong component statistics for simulation (67): * Single equations (assignments): 45 * Array equations: 0 * Algorithm blocks: 0 * Record equations: 18 * When equations: 4 * If-equations: 0 * Equation systems (not torn): 0 * Torn equation systems: 0 * Mixed (continuous/discrete) equation systems: 0 [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.2-main/Internals/VLEFluidConfigurations/FullyMixtureCompatible/VLEFluid.mo:116:25-117:61:writable] Warning: Could not find library TILMedia182ClaRa in either of: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia182ClaRa.a /usr/lib/x86_64-linux-gnu/libTILMedia182ClaRa.a /lib/x86_64-linux-gnu/libTILMedia182ClaRa.a /usr/lib//libTILMedia182ClaRa.a /lib//libTILMedia182ClaRa.a /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia182ClaRa.a /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia182ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/binaries/TransiEnt/libTILMedia182ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/x86_64-linux/libTILMedia182ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/linux64/libTILMedia182ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/libTILMedia182ClaRa.a /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia182ClaRa.so /usr/lib/x86_64-linux-gnu/libTILMedia182ClaRa.so /lib/x86_64-linux-gnu/libTILMedia182ClaRa.so /usr/lib//libTILMedia182ClaRa.so /lib//libTILMedia182ClaRa.so /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia182ClaRa.so /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia182ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/binaries/TransiEnt/libTILMedia182ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/x86_64-linux/libTILMedia182ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/linux64/libTILMedia182ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/libTILMedia182ClaRa.so [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.2-main/Internals/VLEFluidConfigurations/FullyMixtureCompatible/VLEFluid.mo:118:25-119:60:writable] Warning: Could not find library TILMedia182ClaRa in either of: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia182ClaRa.a /usr/lib/x86_64-linux-gnu/libTILMedia182ClaRa.a /lib/x86_64-linux-gnu/libTILMedia182ClaRa.a /usr/lib//libTILMedia182ClaRa.a /lib//libTILMedia182ClaRa.a /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia182ClaRa.a /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia182ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/binaries/TransiEnt/libTILMedia182ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/x86_64-linux/libTILMedia182ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/linux64/libTILMedia182ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/libTILMedia182ClaRa.a /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia182ClaRa.so /usr/lib/x86_64-linux-gnu/libTILMedia182ClaRa.so /lib/x86_64-linux-gnu/libTILMedia182ClaRa.so /usr/lib//libTILMedia182ClaRa.so /lib//libTILMedia182ClaRa.so /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia182ClaRa.so /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia182ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/binaries/TransiEnt/libTILMedia182ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/x86_64-linux/libTILMedia182ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/linux64/libTILMedia182ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/libTILMedia182ClaRa.so [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.2-main/Internals/VLEFluidConfigurations/FullyMixtureCompatible/VLEFluid.mo:116:25-117:61:writable] Warning: Could not find library TILMedia182ClaRa in either of: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia182ClaRa.a /usr/lib/x86_64-linux-gnu/libTILMedia182ClaRa.a /lib/x86_64-linux-gnu/libTILMedia182ClaRa.a /usr/lib//libTILMedia182ClaRa.a /lib//libTILMedia182ClaRa.a /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia182ClaRa.a /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia182ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/binaries/TransiEnt/libTILMedia182ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/x86_64-linux/libTILMedia182ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/linux64/libTILMedia182ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/libTILMedia182ClaRa.a /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia182ClaRa.so /usr/lib/x86_64-linux-gnu/libTILMedia182ClaRa.so /lib/x86_64-linux-gnu/libTILMedia182ClaRa.so /usr/lib//libTILMedia182ClaRa.so /lib//libTILMedia182ClaRa.so /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia182ClaRa.so /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia182ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/binaries/TransiEnt/libTILMedia182ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/x86_64-linux/libTILMedia182ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/linux64/libTILMedia182ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/libTILMedia182ClaRa.so [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.2-main/Internals/VLEFluidConfigurations/FullyMixtureCompatible/VLEFluid.mo:118:25-119:60:writable] Warning: Could not find library TILMedia182ClaRa in either of: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia182ClaRa.a /usr/lib/x86_64-linux-gnu/libTILMedia182ClaRa.a /lib/x86_64-linux-gnu/libTILMedia182ClaRa.a /usr/lib//libTILMedia182ClaRa.a /lib//libTILMedia182ClaRa.a /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia182ClaRa.a /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia182ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/binaries/TransiEnt/libTILMedia182ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/x86_64-linux/libTILMedia182ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/linux64/libTILMedia182ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/libTILMedia182ClaRa.a /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia182ClaRa.so /usr/lib/x86_64-linux-gnu/libTILMedia182ClaRa.so /lib/x86_64-linux-gnu/libTILMedia182ClaRa.so /usr/lib//libTILMedia182ClaRa.so /lib//libTILMedia182ClaRa.so /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia182ClaRa.so /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia182ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/binaries/TransiEnt/libTILMedia182ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/x86_64-linux/libTILMedia182ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/linux64/libTILMedia182ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/libTILMedia182ClaRa.so [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.2-main/Internals/VLEFluidConfigurations/FullyMixtureCompatible/VLEFluid.mo:116:25-117:61:writable] Warning: Could not find library TILMedia182ClaRa in either of: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia182ClaRa.a /usr/lib/x86_64-linux-gnu/libTILMedia182ClaRa.a /lib/x86_64-linux-gnu/libTILMedia182ClaRa.a /usr/lib//libTILMedia182ClaRa.a /lib//libTILMedia182ClaRa.a /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia182ClaRa.a /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia182ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/binaries/TransiEnt/libTILMedia182ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/x86_64-linux/libTILMedia182ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/linux64/libTILMedia182ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/libTILMedia182ClaRa.a /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia182ClaRa.so /usr/lib/x86_64-linux-gnu/libTILMedia182ClaRa.so /lib/x86_64-linux-gnu/libTILMedia182ClaRa.so /usr/lib//libTILMedia182ClaRa.so /lib//libTILMedia182ClaRa.so /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia182ClaRa.so /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia182ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/binaries/TransiEnt/libTILMedia182ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/x86_64-linux/libTILMedia182ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/linux64/libTILMedia182ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/libTILMedia182ClaRa.so [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.2-main/Internals/VLEFluidConfigurations/FullyMixtureCompatible/VLEFluid.mo:118:25-119:60:writable] Warning: Could not find library TILMedia182ClaRa in either of: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia182ClaRa.a /usr/lib/x86_64-linux-gnu/libTILMedia182ClaRa.a /lib/x86_64-linux-gnu/libTILMedia182ClaRa.a /usr/lib//libTILMedia182ClaRa.a /lib//libTILMedia182ClaRa.a /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia182ClaRa.a /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia182ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/binaries/TransiEnt/libTILMedia182ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/x86_64-linux/libTILMedia182ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/linux64/libTILMedia182ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/libTILMedia182ClaRa.a /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia182ClaRa.so /usr/lib/x86_64-linux-gnu/libTILMedia182ClaRa.so /lib/x86_64-linux-gnu/libTILMedia182ClaRa.so /usr/lib//libTILMedia182ClaRa.so /lib//libTILMedia182ClaRa.so /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia182ClaRa.so /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia182ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/binaries/TransiEnt/libTILMedia182ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/x86_64-linux/libTILMedia182ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/linux64/libTILMedia182ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/libTILMedia182ClaRa.so Notification: Performance of Backend phase and start with SimCode phase: time 0.003745/2.301, allocations: 1.187 MB / 3.532 GB, free: 1.68 MB / 1.545 GB Notification: Performance of simCode: created initialization part: time 0.005242/2.306, allocations: 2.618 MB / 3.534 GB, free: 356 kB / 1.545 GB Notification: Performance of simCode: created event and clocks part: time 1.055e-05/2.306, allocations: 1.062 kB / 3.534 GB, free: 356 kB / 1.545 GB Notification: Performance of simCode: created simulation system equations: time 0.001528/2.308, allocations: 1.043 MB / 3.535 GB, free: 15.54 MB / 1.561 GB Notification: Performance of simCode: created of all other equations (e.g. parameter, nominal, assert, etc): time 0.003908/2.312, allocations: 0.6667 MB / 3.536 GB, free: 15.22 MB / 1.561 GB Warning: The hideResult annotation could not be evaluated, probably due to missing annotation(Evaluate=true). It is removed. Notification: Performance of simCode: created linear, non-linear and system jacobian parts: time 0.01565/2.327, allocations: 7.889 MB / 3.543 GB, free: 11.2 MB / 1.561 GB Notification: Performance of simCode: some other stuff during SimCode phase: time 0.003397/2.331, allocations: 2.645 MB / 3.546 GB, free: 10.2 MB / 1.561 GB Notification: Performance of simCode: all other stuff during SimCode phase: time 0.001072/2.332, allocations: 357.3 kB / 3.546 GB, free: 10.16 MB / 1.561 GB Notification: Performance of SimCode: time 1.112e-06/2.332, allocations: 3.938 kB / 3.546 GB, free: 10.16 MB / 1.561 GB Notification: Performance of Templates: time 0.091/2.423, allocations: 51.31 MB / 3.597 GB, free: 10.54 MB / 1.608 GB " [Timeout remaining time 658] make -j1 -f TransiEnt_TransiEnt.Components.Boundaries.Heat.Check.Test_Heatflow_L1_idContrQFlow.makefile [Timeout 660] make -j1 -f TransiEnt_TransiEnt.Components.Boundaries.Heat.Check.Test_Heatflow_L1_idContrQFlow.makefile clang++ -std=c++17 -fopenmp=libomp -Winvalid-pch -O2 -g -DNDEBUG -fPIC -std=c++11 -DBOOST_ALL_DYN_LINK -DUSE_DGESV -DUSE_LOGGER -DOMC_BUILD -DUSE_THREAD -DSUNDIALS_MAJOR_VERSION=5 -DSUNDIALS_MINOR_VERSION=4 -DPMC_USE_SUNDIALS -I"." -I"/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelica/OMCompiler/build/bin/../include/omc/cpp/" -I. "-I/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/C-Sources" -I"." -I"." -I"/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelica/OMCompiler/build/include/omc/sundials" "-I/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/C-Sources" -DMEASURETIME_PROFILEBLOCKS -DUSE_LOGGER -c -o OMCppTransiEnt_TransiEnt.Components.Boundaries.Heat.Check.Test_Heatflow_L1_idContrQFlowCalcHelperMain.o OMCppTransiEnt_TransiEnt.Components.Boundaries.Heat.Check.Test_Heatflow_L1_idContrQFlowCalcHelperMain.cpp In file included from OMCppTransiEnt_TransiEnt.Components.Boundaries.Heat.Check.Test_Heatflow_L1_idContrQFlowCalcHelperMain.cpp:28: ./OMCppTransiEnt_TransiEnt.Components.Boundaries.Heat.Check.Test_Heatflow_L1_idContrQFlowFunctions.cpp:887:25: error: no matching function for call to 'TILMedia_createExternalObject' externalObject__ext = TILMedia_createExternalObject(objectType_.c_str(), mediumName_.c_str(), flags__ext, ConstArray(xi_).getData(), nc__ext, condensingIndex__ext, instanceName_.c_str()); ^~~~~~~~~~~~~~~~~~~~~~~~~~~~~ ./OMCppTransiEnt_TransiEnt.Components.Boundaries.Heat.Check.Test_Heatflow_L1_idContrQFlowFunctions.cpp:54:7: note: candidate function not viable: 4th argument ('const double *') would lose const qualifier void* TILMedia_createExternalObject(const char* objectType, const char* mixtureName, int flags, double* xi, int _nc, int condensingIndex, const char* instanceName) { ^ ./OMCppTransiEnt_TransiEnt.Components.Boundaries.Heat.Check.Test_Heatflow_L1_idContrQFlowFunctions.cpp:932:12: error: no matching function for call to 'TILMedia_VLEFluidObjectFunctions_density_pTxi' d__ext = TILMedia_VLEFluidObjectFunctions_density_pTxi(p__ext, T__ext, ConstArray(xi_).getData(), vleFluidPointer__ext); ^~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ ./OMCppTransiEnt_TransiEnt.Components.Boundaries.Heat.Check.Test_Heatflow_L1_idContrQFlowFunctions.cpp:14:8: note: candidate function not viable: 3rd argument ('const double *') would lose const qualifier double TILMedia_VLEFluidObjectFunctions_density_pTxi(double, double, double*, void*); ^ ./OMCppTransiEnt_TransiEnt.Components.Boundaries.Heat.Check.Test_Heatflow_L1_idContrQFlowFunctions.cpp:958:12: error: no matching function for call to 'TILMedia_VLEFluidObjectFunctions_specificEnthalpy_pTxi' h__ext = TILMedia_VLEFluidObjectFunctions_specificEnthalpy_pTxi(p__ext, T__ext, ConstArray(xi_).getData(), vleFluidPointer__ext); ^~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ ./OMCppTransiEnt_TransiEnt.Components.Boundaries.Heat.Check.Test_Heatflow_L1_idContrQFlowFunctions.cpp:13:8: note: candidate function not viable: 3rd argument ('const double *') would lose const qualifier double TILMedia_VLEFluidObjectFunctions_specificEnthalpy_pTxi(double, double, double*, void*); ^ ./OMCppTransiEnt_TransiEnt.Components.Boundaries.Heat.Check.Test_Heatflow_L1_idContrQFlowFunctions.cpp:984:12: error: no matching function for call to 'TILMedia_VLEFluidObjectFunctions_specificEntropy_pTxi' s__ext = TILMedia_VLEFluidObjectFunctions_specificEntropy_pTxi(p__ext, T__ext, ConstArray(xi_).getData(), vleFluidPointer__ext); ^~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ ./OMCppTransiEnt_TransiEnt.Components.Boundaries.Heat.Check.Test_Heatflow_L1_idContrQFlowFunctions.cpp:12:8: note: candidate function not viable: 3rd argument ('const double *') would lose const qualifier double TILMedia_VLEFluidObjectFunctions_specificEntropy_pTxi(double, double, double*, void*); ^ ./OMCppTransiEnt_TransiEnt.Components.Boundaries.Heat.Check.Test_Heatflow_L1_idContrQFlowFunctions.cpp:1059:3: error: no matching function for call to 'TILMedia_VLEFluid_VLEProperties_phxi' TILMedia_VLEFluid_VLEProperties_phxi(p__ext, h__ext, ConstArray(xi_).getData(), vleFluidPointer__ext, &d_l__ext, &h_l__ext, &p_l__ext, &s_l__ext, &T_l__ext, xi_l_.getData(), &d_v__ext, &h_v__ext, &p_v__ext, &s_v__ext, &T_v__ext, xi_v_.getData()); ^~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ ./OMCppTransiEnt_TransiEnt.Components.Boundaries.Heat.Check.Test_Heatflow_L1_idContrQFlowFunctions.cpp:10:6: note: candidate function not viable: 3rd argument ('const double *') would lose const qualifier void TILMedia_VLEFluid_VLEProperties_phxi(double, double, double*, void*, double*, double*, double*, double*, double*, double*, ^ ./OMCppTransiEnt_TransiEnt.Components.Boundaries.Heat.Check.Test_Heatflow_L1_idContrQFlowFunctions.cpp:1156:3: error: no matching function for call to 'TILMedia_VLEFluid_additionalProperties_phxi' TILMedia_VLEFluid_additionalProperties_phxi(p__ext, h__ext, ConstArray(xi_).getData(), vleFluidPointer__ext, &x__ext, &cp__ext, &cv__ext, &beta__ext, &kappa__ext, &drhodp__ext, &drhodh__ext, drhodxi_.getData(), &a__ext, &gamma__ext); ^~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ ./OMCppTransiEnt_TransiEnt.Components.Boundaries.Heat.Check.Test_Heatflow_L1_idContrQFlowFunctions.cpp:9:6: note: candidate function not viable: 3rd argument ('const double *') would lose const qualifier void TILMedia_VLEFluid_additionalProperties_phxi(double, double, double*, void*, double*, double*, double*, double*, double*, double*, double*, double*, double*, double*); ^ ./OMCppTransiEnt_TransiEnt.Components.Boundaries.Heat.Check.Test_Heatflow_L1_idContrQFlowFunctions.cpp:1223:3: error: no matching function for call to 'TILMedia_VLEFluid_cricondenbar_xi' TILMedia_VLEFluid_cricondenbar_xi(ConstArray(xi_).getData(), vleFluidPointer__ext, &d__ext, &h__ext, &p__ext, &s__ext, &T__ext); ^~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ ./OMCppTransiEnt_TransiEnt.Components.Boundaries.Heat.Check.Test_Heatflow_L1_idContrQFlowFunctions.cpp:8:6: note: candidate function not viable: 1st argument ('const double *') would lose const qualifier void TILMedia_VLEFluid_cricondenbar_xi(double*, void*, double*, double*, double*, double*, double*); ^ ./OMCppTransiEnt_TransiEnt.Components.Boundaries.Heat.Check.Test_Heatflow_L1_idContrQFlowFunctions.cpp:1311:12: error: no matching function for call to 'TILMedia_VLEFluid_Cached_specificEnthalpy_pTxi' h__ext = TILMedia_VLEFluid_Cached_specificEnthalpy_pTxi(p__ext, T__ext, ConstArray(xi_).getData(), vleFluidPointer__ext); ^~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ ./OMCppTransiEnt_TransiEnt.Components.Boundaries.Heat.Check.Test_Heatflow_L1_idContrQFlowFunctions.cpp:6:8: note: candidate function not viable: 3rd argument ('const double *') would lose const qualifier double TILMedia_VLEFluid_Cached_specificEnthalpy_pTxi(double, double, double*, void*); ^ ./OMCppTransiEnt_TransiEnt.Components.Boundaries.Heat.Check.Test_Heatflow_L1_idContrQFlowFunctions.cpp:1337:12: error: no matching function for call to 'TILMedia_VLEFluid_Cached_specificEntropy_pTxi' s__ext = TILMedia_VLEFluid_Cached_specificEntropy_pTxi(p__ext, T__ext, ConstArray(xi_).getData(), vleFluidPointer__ext); ^~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ ./OMCppTransiEnt_TransiEnt.Components.Boundaries.Heat.Check.Test_Heatflow_L1_idContrQFlowFunctions.cpp:5:8: note: candidate function not viable: 3rd argument ('const double *') would lose const qualifier double TILMedia_VLEFluid_Cached_specificEntropy_pTxi(double, double, double*, void*); ^ ./OMCppTransiEnt_TransiEnt.Components.Boundaries.Heat.Check.Test_Heatflow_L1_idContrQFlowFunctions.cpp:1363:12: error: no matching function for call to 'TILMedia_VLEFluid_Cached_specificEnthalpy_pTxi' h__ext = TILMedia_VLEFluid_Cached_specificEnthalpy_pTxi(p__ext, T__ext, ConstArray(xi_).getData(), vleFluidPointer__ext); ^~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ ./OMCppTransiEnt_TransiEnt.Components.Boundaries.Heat.Check.Test_Heatflow_L1_idContrQFlowFunctions.cpp:6:8: note: candidate function not viable: 3rd argument ('const double *') would lose const qualifier double TILMedia_VLEFluid_Cached_specificEnthalpy_pTxi(double, double, double*, void*); ^ ./OMCppTransiEnt_TransiEnt.Components.Boundaries.Heat.Check.Test_Heatflow_L1_idContrQFlowFunctions.cpp:1389:12: error: no matching function for call to 'TILMedia_VLEFluid_Cached_specificEntropy_pTxi' s__ext = TILMedia_VLEFluid_Cached_specificEntropy_pTxi(p__ext, T__ext, ConstArray(xi_).getData(), vleFluidPointer__ext); ^~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ ./OMCppTransiEnt_TransiEnt.Components.Boundaries.Heat.Check.Test_Heatflow_L1_idContrQFlowFunctions.cpp:5:8: note: candidate function not viable: 3rd argument ('const double *') would lose const qualifier double TILMedia_VLEFluid_Cached_specificEntropy_pTxi(double, double, double*, void*); ^ ./OMCppTransiEnt_TransiEnt.Components.Boundaries.Heat.Check.Test_Heatflow_L1_idContrQFlowFunctions.cpp:1415:12: error: no matching function for call to 'TILMedia_VLEFluid_Cached_specificEnthalpy_pTxi' h__ext = TILMedia_VLEFluid_Cached_specificEnthalpy_pTxi(p__ext, T__ext, ConstArray(xi_).getData(), vleFluidPointer__ext); ^~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ ./OMCppTransiEnt_TransiEnt.Components.Boundaries.Heat.Check.Test_Heatflow_L1_idContrQFlowFunctions.cpp:6:8: note: candidate function not viable: 3rd argument ('const double *') would lose const qualifier double TILMedia_VLEFluid_Cached_specificEnthalpy_pTxi(double, double, double*, void*); ^ ./OMCppTransiEnt_TransiEnt.Components.Boundaries.Heat.Check.Test_Heatflow_L1_idContrQFlowFunctions.cpp:1441:12: error: no matching function for call to 'TILMedia_VLEFluid_Cached_specificEntropy_pTxi' s__ext = TILMedia_VLEFluid_Cached_specificEntropy_pTxi(p__ext, T__ext, ConstArray(xi_).getData(), vleFluidPointer__ext); ^~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ ./OMCppTransiEnt_TransiEnt.Components.Boundaries.Heat.Check.Test_Heatflow_L1_idContrQFlowFunctions.cpp:5:8: note: candidate function not viable: 3rd argument ('const double *') would lose const qualifier double TILMedia_VLEFluid_Cached_specificEntropy_pTxi(double, double, double*, void*); ^ 13 errors generated. make: *** [: OMCppTransiEnt_TransiEnt.Components.Boundaries.Heat.Check.Test_Heatflow_L1_idContrQFlowCalcHelperMain.o] Error 1 [Calling os._exit(0), Time elapsed: 18.986092207953334] Failed to read output from testmodel.py, exit status != 0: 2.43145943316631 2.444377789 0.290297499 Calling exit ...