Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr TAeZoSysPro_testsuite_TAeZoSysPro_testsuite.FluidDynamics.Components.Valves.test_CommissioningDamper.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.001253/0.001259, allocations: 111.6 kB / 17.08 MB, free: 6.012 MB / 14.72 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001247/0.001247, allocations: 193.2 kB / 20.03 MB, free: 3.082 MB / 14.72 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.404/1.404, allocations: 205.1 MB / 227.9 MB, free: 4.414 MB / 174.1 MB " [Timeout remaining time 178] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/TAeZoSysPro master/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/TAeZoSysPro master/package.mo): time 0.06922/0.06922, allocations: 10.98 MB / 288.3 MB, free: 8.051 MB / 238.1 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/TAeZoSysPro_testsuite master/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/TAeZoSysPro_testsuite master/package.mo): time 0.01974/0.01974, allocations: 4.253 MB / 344 MB, free: 26.78 MB / 254.1 MB " [Timeout remaining time 180] Using package TAeZoSysPro_testsuite with version (/home/hudson/saved_omc/libraries/.openmodelica/libraries/TAeZoSysPro_testsuite master/package.mo) Using package TAeZoSysPro with version (/home/hudson/saved_omc/libraries/.openmodelica/libraries/TAeZoSysPro master/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Running command: translateModel(TAeZoSysPro_testsuite.FluidDynamics.Components.Valves.test_CommissioningDamper,tolerance=1e-06,outputFormat="empty",numberOfIntervals=500,variableFilter="",fileNamePrefix="TAeZoSysPro_testsuite_TAeZoSysPro_testsuite.FluidDynamics.Components.Valves.test_CommissioningDamper") translateModel(TAeZoSysPro_testsuite.FluidDynamics.Components.Valves.test_CommissioningDamper,tolerance=1e-06,outputFormat="empty",numberOfIntervals=500,variableFilter="",fileNamePrefix="TAeZoSysPro_testsuite_TAeZoSysPro_testsuite.FluidDynamics.Components.Valves.test_CommissioningDamper") [Timeout 660] "Notification: Modelica requested package Complex of version 3.2.3. Complex 4.0.0 is used instead which states that it is fully compatible without conversion script needed. Notification: Modelica requested package ModelicaServices of version 3.2.3. ModelicaServices 4.0.0 is used instead which states that it is fully compatible without conversion script needed. Notification: Performance of FrontEnd - loaded program: time 0.002098/0.002098, allocations: 75.31 kB / 459 MB, free: 45.18 MB / 318.1 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.09022/0.09233, allocations: 49.75 MB / 0.4968 GB, free: 12.34 MB / 334.1 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TAeZoSysPro_testsuite master/FluidDynamics/Components/Valves/test_CommissioningDamper.mo:5:144-5:163:writable] Error: Modified element dp_nominal not found in class CommissioningDamper. Notification: Performance of FrontEnd: time 0.001773/0.09417, allocations: 0.5164 MB / 0.4973 GB, free: 11.83 MB / 334.1 MB " [Timeout remaining time 660] [Calling sys.exit(0), Time elapsed: 2.5588387141469866] Failed to read output from testmodel.py, exit status != 0: 0.10072632296942174 0.11462427500000001 -1.0 Calling exit ...