Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr Dynawo_dev_Dynawo.Examples.SVarC.SVarCLoadVarQ.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.001723/0.001723, allocations: 108.8 kB / 17.07 MB, free: 6.082 MB / 14.72 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001734/0.001734, allocations: 190.2 kB / 20.02 MB, free: 3.168 MB / 14.72 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.562/1.562, allocations: 205.1 MB / 227.9 MB, free: 4.328 MB / 174.1 MB " [Timeout remaining time 178] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/package.mo): time 0.5313/0.5313, allocations: 101.5 MB / 378.7 MB, free: 3.441 MB / 302.1 MB " [Timeout remaining time 179] Using package Dynawo with version 1.7.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Running command: translateModel(Dynawo.Examples.SVarC.SVarCLoadVarQ,tolerance=1e-06,outputFormat="empty",numberOfIntervals=500,variableFilter="",fileNamePrefix="Dynawo_dev_Dynawo.Examples.SVarC.SVarCLoadVarQ") translateModel(Dynawo.Examples.SVarC.SVarCLoadVarQ,tolerance=1e-06,outputFormat="empty",numberOfIntervals=500,variableFilter="",fileNamePrefix="Dynawo_dev_Dynawo.Examples.SVarC.SVarCLoadVarQ") [Timeout 660] "Notification: Modelica requested package Complex of version 3.2.3. Complex 4.0.0 is used instead which states that it is fully compatible without conversion script needed. Notification: Modelica requested package ModelicaServices of version 3.2.3. ModelicaServices 4.0.0 is used instead which states that it is fully compatible without conversion script needed. Notification: Performance of FrontEnd - loaded program: time 0.002093/0.002093, allocations: 67.89 kB / 0.5257 GB, free: 500 kB / 382.1 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1445/0.1466, allocations: 71.67 MB / 0.5957 GB, free: 8.801 MB / 462.1 MB Notification: Performance of NFInst.instantiate(Dynawo.Examples.SVarC.SVarCLoadVarQ): time 0.007021/0.1536, allocations: 5.094 MB / 0.6007 GB, free: 3.672 MB / 462.1 MB Notification: Performance of NFInst.instExpressions: time 0.005091/0.1588, allocations: 2.931 MB / 0.6035 GB, free: 0.7266 MB / 462.1 MB Notification: Performance of NFInst.updateImplicitVariability: time 0.0005282/0.1593, allocations: 15.94 kB / 0.6036 GB, free: 0.7109 MB / 462.1 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:22:3-22:125:writable] Warning: Connector switchOffSignal3 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/StaticVarCompensators/BaseControls/ModeHandling.mo:34:3-35:199:writable] Warning: Connector mode is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/StaticVarCompensators/BaseControls/ModeHandling.mo:36:3-36:116:writable] Warning: Connector modeAuto is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/StaticVarCompensators/BaseControls/ModeHandling.mo:37:3-37:115:writable] Warning: Connector modeManual is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/StaticVarCompensators/BaseControls/CalculationBG.mo:28:3-29:205:writable] Warning: Connector mode is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Loads/BaseClasses/BaseLoad.mo:32:3-32:125:writable] Warning: Connector UPu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). Notification: Performance of NFTyping.typeComponents: time 0.0007595/0.1601, allocations: 197.9 kB / 0.6037 GB, free: 0.5195 MB / 462.1 MB Notification: Performance of NFTyping.typeBindings: time 0.0006442/0.1608, allocations: 234.2 kB / 0.604 GB, free: 296 kB / 462.1 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Examples/SVarC/SVarCLoadVarQ.mo:38:3-38:38:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Examples/SVarC/SVarCLoadVarQ.mo:40:3-40:56:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Examples/SVarC/SVarCLoadVarQ.mo:41:3-41:56:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Examples/SVarC/SVarCLoadVarQ.mo:43:3-43:40:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. Notification: Performance of NFTyping.typeClassSections: time 0.002051/0.1628, allocations: 0.9549 MB / 0.6049 GB, free: 15.33 MB / 478.1 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Sources/InjectorBG.mo:40:3-40:78:writable] Error: Parameter sVarCStandard.injector.G0Pu has neither value nor start value, and is fixed during initialization (fixed=true). Notification: Performance of FrontEnd: time 0.0003411/0.1632, allocations: 242.9 kB / 0.6051 GB, free: 15.1 MB / 478.1 MB " [Timeout remaining time 660] [Calling sys.exit(0), Time elapsed: 3.1618544361554086] Failed to read output from testmodel.py, exit status != 0: 0.16958599211648107 0.18241289099999994 -1.0 Calling exit ...