Environment - simulationEnvironment: startTime=0 stopTime=86400 tolerance=1e-06 numberOfIntervals=2500 stepSize=34.56 Regular simulation: ./Buildings_latest_Buildings.Fluid.HydronicConfigurations.ActiveNetworks.Examples.InjectionTwoWayVariableReturn -abortSlowSimulation -alarm=800 -emit_protected -lv LOG_STATS WARNING: other : Warning: unrecognized command line options -abortSlowSimulation INFO : solver: SimManager: Start initialization *** Warning: In InjectionTwoWayVariableReturn.con: Return temperature control is likely not compatible with a variable flow consumer circuit. INFO : solver: SimManager: Start simulation at t = 0.000000 ERROR : solver: DASSL: failed step at t = 79227.525123: In InjectionTwoWayVariableReturn.loaOpe.loa.coi.heaCoo.vol.steBal: The heat flow rate equals nan W and the mass flow rate equals 0.000001 kg/s, which results in a temperature difference nan K > dTMax=200.000000 K. This may indicate that energy is not conserved for small mass flow rates. The implementation may require prescribedHeatFlowRate = false. ERROR : solver: SimManager: Simulation stopped with errors before t = 86400.000000 ERROR : solver: SimManager: DASSL: solve failed with idid = 1 INFO : solver: SimManager: Simulation stop time: 86400.000000 INFO : solver: Simulation info from solver: INFO : solver: DASSL: steps taken nst = 14073 INFO : solver: DASSL: residual evaluations nre = 26816 INFO : solver: DASSL: jacobian evaluations nje = 15585 INFO : solver: DASSL: root evaluations nrt = 14092 INFO : solver: DASSL: error test failures netf = 162 INFO : solver: DASSL: nonlinear convergence failures ncfn = 5056 INFO : solver: DASSL: nonlinear iterations nni = 26816 INFO : solver: DASSL: last evaluation time t = 79227.525123 INFO : solver: DASSL: last step size h = 0.809926 INFO : solver: DASSL: last used order k = 2 ERROR : solver: SimController: Simulation failed using nonlinear solver newton ERROR : solver: SimController: Recovering with nonlinear solver kinsol INFO : solver: SimManager: Start initialization *** Warning: In InjectionTwoWayVariableReturn.con: Return temperature control is likely not compatible with a variable flow consumer circuit. INFO : solver: SimManager: Start simulation at t = 0.000000 INFO : solver: SimManager: Simulation stop time: 86400.000000 INFO : solver: Simulation info from solver: INFO : solver: DASSL: steps taken nst = 4377 INFO : solver: DASSL: residual evaluations nre = 6051 INFO : solver: DASSL: jacobian evaluations nje = 560 INFO : solver: DASSL: root evaluations nrt = 4396 INFO : solver: DASSL: error test failures netf = 204 INFO : solver: DASSL: nonlinear convergence failures ncfn = 32 INFO : solver: DASSL: nonlinear iterations nni = 6051 INFO : solver: DASSL: last evaluation time t = 86424.375848 INFO : solver: DASSL: last step size h = 34.560000 INFO : solver: DASSL: last used order k = 2