ThermoPower test using OpenModelica

Total Frontend Backend SimCode Templates Compilation Simulation Verification
108 101 101 101 100 99 97 0

Test started: 2024-06-26 20:16:12
Total time taken: 0:35:10
System info: AMD Ryzen 9 5950X 16-Core Processor, 63 GB RAM, Ubuntu 22.04.3 LTS

OpenModelica Version: OMCompiler v1.22.3-v1.22.3.1+g24592ab6d0

OpenModelicaLibraryTesting Changes

CommitDateAuthorSummary
b3682912024-06-20 15:15:32 +0200Adrian Popadd MSL maint/4.1.x via 4.1.0-beta.om (#115)

Tested Library: ThermoPower 3.1

{
 "path": "ThermoPower",
 "sha": "e2b011ac7fd90f9cf5771f29f1aefa160550b6ee",
 "support": "experimental",
 "uses": {
  "Modelica": "3.2.3"
 },
 "version": "3.1.0-master",
 "zipfile": "https://github.com/casella/ThermoPower/archive/e2b011ac7fd90f9cf5771f29f1aefa160550b6ee.zip"
}

BuildModel time limit: 660s
Simulation time limit: 480s
Default tolerance: 1e-06
Optimization level: -Os -march=native

Flags:
setCommandLineOptions("-d=nogen");
setCommandLineOptions("-d=initialization");
setCommandLineOptions("-d=backenddaeinfo");
setCommandLineOptions("-d=discreteinfo");
setCommandLineOptions("-d=stateselection");
setCommandLineOptions("-d=execstat");
setMatchingAlgorithm("PFPlusExt");
setIndexReductionMethod("dynamicStateSelection");
Config:
{
 "library": "ThermoPower",
 "optlevel": "-Os -march=native"
}

Links are provided if getErrorString() or the simulation generates output. The links are coded with red if there were errors, yellow if there were warnings, and normal links if there are only notifications.

ModelVerifiedSimulateTotal buildModelParsingFrontendBackendSimCodeTemplatesCompileTotal Execution
ThermoPower.Examples.BraytonCycle.ClosedLoopSimulator (sim) 0.404.991.950.590.360.030.093.917.78
ThermoPower.Examples.BraytonCycle.OpenLoopSimulator (sim) 0.385.011.970.610.390.030.103.887.84
ThermoPower.Examples.CISE.Simulators.CISESim2States120501 (sim) 1.2012.122.150.562.800.130.418.2315.98
ThermoPower.Examples.CISE.Simulators.CISESim120501 (sim) 4.6221.872.350.804.720.311.0015.0429.35
ThermoPower.Examples.CISE.Simulators.CISESim180503 (sim) 96.1221.322.410.804.800.311.0314.39120.37
ThermoPower.Examples.CISE.Simulators.CISESim180504 (sim) 26.5421.402.380.784.890.351.0114.3750.83
ThermoPower.Examples.HRB.Simulators.ClosedLoopDigitalSimulator (sim) 10.6514.121.990.941.680.170.5510.7827.28
ThermoPower.Examples.HRB.Simulators.ClosedLoopDigitalSimulatorSimplified (sim) 0.989.281.950.921.040.140.426.7712.69
ThermoPower.Examples.HRB.Simulators.ClosedLoopSimulator (sim) 8.6514.191.980.931.730.190.6010.7525.37
ThermoPower.Examples.HRB.Simulators.OpenLoopSimulator (sim) 1.2412.672.061.021.850.210.269.3416.45
ThermoPower.Examples.HRB.Simulators.OpenLoopSimulatorHtc 0.003.291.910.911.460.360.560.005.72
ThermoPower.Examples.HRB.Simulators.OpenLoopSimulatorSS (sim) 2.5714.082.010.961.770.180.5410.6219.18
ThermoPower.Examples.HRB.Simulators.OpenLoopSimulatorSimplified (sim) 0.249.401.940.991.000.140.376.9012.05
ThermoPower.Examples.HRB.Simulators.TestPI (sim) 0.021.871.890.100.010.000.021.744.26
ThermoPower.Examples.RankineCycle.Simulators.ClosedLoop (sim) 9.1223.461.971.224.990.611.0915.5435.03
ThermoPower.PowerPlants.ElectricGeneratorGroup.Tests.Test_Generator_SE 0.000.131.890.130.000.000.000.002.51
ThermoPower.PowerPlants.ElectricGeneratorGroup.Tests.Test_Generator_SE_breaker 0.000.141.940.140.000.000.000.002.61
ThermoPower.PowerPlants.ElectricGeneratorGroup.Tests.Test_Generator_SE_com 0.000.141.880.140.000.000.000.002.48
ThermoPower.PowerPlants.Simulators.CCPP_Sim3 0.001.772.101.770.000.000.000.004.40
ThermoPower.PowerPlants.Simulators.SteamPlant_Sim1 0.002.521.982.520.000.000.000.005.02
ThermoPower.PowerPlants.Simulators.SteamPlant_Sim1_dp 0.001.722.091.720.000.000.000.004.39
ThermoPower.PowerPlants.Simulators.SteamPlant_Sim2 0.002.501.952.500.000.000.000.004.98
ThermoPower.PowerPlants.SteamTurbineGroup.Tests.TestST3LRh_base (sim) 0.156.242.060.520.180.020.265.268.93
ThermoPower.PowerPlants.SteamTurbineGroup.Tests.TestST3LRh_bypass (sim) 0.737.192.020.600.430.030.096.0410.41
ThermoPower.PowerPlants.SteamTurbineGroup.Tests.TestST3LRh_valve (sim) 1.156.772.020.530.250.190.095.7110.43
ThermoPower.PowerPlants.SteamTurbineGroup.Tests.TestSTG_cc (sim) 3.627.201.980.550.450.020.096.0813.26
ThermoPower.PowerPlants.SteamTurbineGroup.Tests.TestTurbineHPefficiency 0.004.331.970.210.340.010.073.696.74
ThermoPower.Test.DistributedParameterComponents.CheckFlow1DFV2phMassBalance (sim) 19.314.561.920.140.440.030.073.8826.26
ThermoPower.Test.DistributedParameterComponents.TestConstantHeatTransferTwoGrid_Fcoarse (sim) 0.072.561.880.240.050.010.042.224.96
ThermoPower.Test.DistributedParameterComponents.TestConstantHeatTransferTwoGrid_Wcoarse (sim) 0.122.661.880.120.060.010.172.295.16
ThermoPower.Test.DistributedParameterComponents.TestFlow1D2phChen (sim) 28.6212.831.870.372.300.300.469.4043.77
ThermoPower.Test.DistributedParameterComponents.TestFlow1D2phChen_hf (sim) 233.6614.101.880.383.910.200.619.00250.09
ThermoPower.Test.DistributedParameterComponents.TestFlow1D2phDB (sim) 15.5612.181.830.362.060.140.439.2030.04
ThermoPower.Test.DistributedParameterComponents.TestFlow1D2phDB_hf (sim) 48.3413.001.850.363.110.160.588.7863.64
ThermoPower.Test.DistributedParameterComponents.TestFlow1Dfem2ph (sim) 6.0422.651.860.396.801.561.0412.8631.02
ThermoPower.Test.DistributedParameterComponents.TestFlowDependentHeatTransferCoefficient2ph (sim) 0.464.691.890.140.440.040.073.997.49
ThermoPower.Test.DistributedParameterComponents.TestGasFlow1DFV_A (sim) 0.094.532.040.520.410.030.073.497.12
ThermoPower.Test.DistributedParameterComponents.TestGasFlow1DFV_B (sim) 0.175.961.970.560.660.050.324.378.61
ThermoPower.Test.DistributedParameterComponents.TestGasFlow1DFV_C (sim) 0.206.212.010.560.700.060.314.588.89
ThermoPower.Test.DistributedParameterComponents.TestHeatTransfer2phDB (sim) 0.684.911.900.140.520.050.094.117.96
ThermoPower.Test.DistributedParameterComponents.TestRefrigerantEvaporator (sim) 52.8317.091.890.913.530.370.6511.6372.29
ThermoPower.Test.DistributedParameterComponents.TestWalls (sim) 0.021.841.870.120.010.010.021.694.17
ThermoPower.Test.DistributedParameterComponents.TestWaterFlow1DFEM_A (sim) 45.229.252.010.451.410.090.406.9056.94
ThermoPower.Test.DistributedParameterComponents.TestWaterFlow1DFEM_B (sim) 16.029.252.020.451.420.110.446.8327.78
ThermoPower.Test.DistributedParameterComponents.TestWaterFlow1DFEM_C (sim) 33.788.912.060.421.270.080.436.7145.21
ThermoPower.Test.DistributedParameterComponents.TestWaterFlow1DFEM_D (sim) 89.538.742.000.411.260.080.396.59100.76
ThermoPower.Test.DistributedParameterComponents.TestWaterFlow1DFEM_E (sim) 65.8814.352.000.522.720.180.8010.1282.74
ThermoPower.Test.DistributedParameterComponents.TestWaterFlow1DFEM_F (sim) 134.2421.061.980.554.290.520.9914.71157.74
ThermoPower.Test.DistributedParameterComponents.TestWaterFlow1DFEM_G (sim) 2.206.292.000.200.850.040.125.0810.93
ThermoPower.Test.DistributedParameterComponents.TestWaterFlow1DFEM_J (sim) 0.807.701.870.181.100.240.156.0410.82
ThermoPower.Test.DistributedParameterComponents.TestWaterFlow1DFEM_K (sim) 0.748.021.950.201.200.250.306.0611.20
ThermoPower.Test.DistributedParameterComponents.TestWaterFlow1DFV2ph (sim) 10.3122.421.850.425.100.371.0815.4535.03
ThermoPower.Test.DistributedParameterComponents.TestWaterFlow1DFV2ph_A (sim) 2.5011.331.910.381.780.280.418.4816.20
ThermoPower.Test.DistributedParameterComponents.TestWaterFlow1DFV2ph_B (sim) 2.4511.191.880.351.800.270.418.3615.97
ThermoPower.Test.DistributedParameterComponents.TestWaterFlow1DFV2ph_C (sim) 17.3722.061.880.385.100.451.0715.0441.77
ThermoPower.Test.DistributedParameterComponents.TestWaterFlow1DFV2ph_D (sim) 2.4611.401.870.361.780.270.418.5816.20
ThermoPower.Test.DistributedParameterComponents.TestWaterFlow1DFV_A (sim) 2.798.531.950.440.790.060.376.8713.72
ThermoPower.Test.DistributedParameterComponents.TestWaterFlow1DFV_A_Fast (sim) 0.134.832.090.470.280.050.283.757.55
ThermoPower.Test.DistributedParameterComponents.TestWaterFlow1DFV_AdaptiveAverageTemp (sim) 0.535.371.900.360.270.020.254.468.25
ThermoPower.Test.DistributedParameterComponents.TestWaterFlow1DFV_B (sim) 1.226.641.960.430.580.040.135.4510.28
ThermoPower.Test.DistributedParameterComponents.TestWaterFlow1DFV_D (sim) 0.345.342.020.180.410.020.254.478.18
ThermoPower.Test.DistributedParameterComponents.TestWaterFlow1DFV_DB (sim) 1.358.002.030.430.720.050.286.5311.87
ThermoPower.Test.DistributedParameterComponents.TestWaterFlow1DFV_E (sim) 5.3415.022.000.471.890.200.8411.6322.82
ThermoPower.Test.DistributedParameterComponents.TestWaterFlow1DFV_F (sim) 5.6816.902.090.571.880.200.8213.4325.14
ThermoPower.Test.ElectricalComponents.TestElectrical1 (sim) 0.021.761.870.100.010.000.011.644.11
ThermoPower.Test.ElectricalComponents.TestElectrical2 (sim) 0.011.841.880.090.010.000.021.724.19
ThermoPower.Test.ElectricalComponents.TestElectrical3 (sim) 0.021.831.950.090.010.000.021.704.28
ThermoPower.Test.ElectricalComponents.TestElectrical4 (sim) 0.021.861.870.090.010.000.021.734.22
ThermoPower.Test.ElectricalComponents.TestElectrical5 (sim) 0.021.861.910.090.020.010.021.724.25
ThermoPower.Test.ElectricalComponents.TestElectrical6 (sim) 0.021.911.880.090.020.010.021.784.28
ThermoPower.Test.ElectricalComponents.TestElectrical7 (sim) 0.021.871.880.090.020.010.021.744.22
ThermoPower.Test.GasComponents.TestCC (sim) 0.433.671.970.480.080.020.222.876.58
ThermoPower.Test.GasComponents.TestCompressorConstSpeed (sim) 0.042.772.010.530.030.010.042.175.26
ThermoPower.Test.GasComponents.TestCompressorInertia (sim) 0.052.721.940.450.030.010.042.205.15
ThermoPower.Test.GasComponents.TestFanMech (sim) 1.062.891.910.430.050.010.042.366.31
ThermoPower.Test.GasComponents.TestGT (sim) 0.042.932.000.460.040.010.052.365.43
ThermoPower.Test.GasComponents.TestGT_ISO (sim) 0.073.101.990.490.050.010.052.505.62
ThermoPower.Test.GasComponents.TestGasMixer (sim) 0.153.272.000.490.070.020.052.635.89
ThermoPower.Test.GasComponents.TestGasTurbine (sim) 0.032.681.950.450.020.010.032.165.14
ThermoPower.Test.GasComponents.TestGasTurbineStodola (sim) 0.032.741.980.510.020.010.042.155.21
ThermoPower.Test.GasComponents.TestGasValve (sim) 0.114.632.000.570.320.020.073.657.21
ThermoPower.Test.GasComponents.TestGasValveOpPoint (sim) 0.084.121.950.530.100.020.253.226.61
ThermoPower.Test.GasComponents.TestTurboJetConstSpeed (sim) 0.554.641.990.560.310.030.083.677.64
ThermoPower.Test.GasComponents.TestTurboJetInertia (sim) 0.634.891.960.620.320.030.093.837.96
ThermoPower.Test.WaterComponents.TestAccumulator (sim) 0.144.272.050.160.280.010.053.776.96
ThermoPower.Test.WaterComponents.TestBarometricCondenser (sim) 0.514.511.940.190.270.010.053.997.45
ThermoPower.Test.WaterComponents.TestCoeffValve (sim) 0.034.421.940.390.090.010.063.876.87
ThermoPower.Test.WaterComponents.TestCoolingTowerClosed (sim) 14.957.702.000.550.770.050.335.9825.12
ThermoPower.Test.WaterComponents.TestCoolingTowerPacking (sim) 1.976.301.950.470.350.050.095.3410.69
ThermoPower.Test.WaterComponents.TestCoolingTowerStatic (sim) 23.075.842.000.510.240.210.094.7931.35
ThermoPower.Test.WaterComponents.TestExpansionTankIdeal (sim) 0.294.992.010.180.390.020.094.307.75
ThermoPower.Test.WaterComponents.TestJoin (sim) 0.324.462.010.430.100.010.063.857.27
ThermoPower.Test.WaterComponents.TestJoinRev (sim) 0.324.771.990.440.140.020.074.117.52
ThermoPower.Test.WaterComponents.TestMixer (sim) 0.284.692.050.450.130.020.084.017.48
ThermoPower.Test.WaterComponents.TestMixerSlowFast (sim) 0.284.552.040.210.310.010.063.977.35
ThermoPower.Test.WaterComponents.TestMixerSlowFastSteam (sim) 0.304.472.050.210.300.010.063.897.29
ThermoPower.Test.WaterComponents.TestST1 (sim) 0.215.801.990.200.310.010.075.208.47
ThermoPower.Test.WaterComponents.TestST2 (sim) 0.175.652.020.190.310.010.075.078.34
ThermoPower.Test.WaterComponents.TestSources (sim) 0.033.202.110.610.020.010.052.525.82
ThermoPower.Test.WaterComponents.TestSplitRev (sim) 0.314.761.940.430.120.020.084.117.49
ThermoPower.Test.WaterComponents.TestTurbineStodolaPartialArc (sim) 0.035.642.020.210.310.010.065.068.16
ThermoPower.Test.WaterComponents.TestValveChoked (sim) 0.034.192.120.180.260.010.053.696.80
ThermoPower.Test.WaterComponents.TestValves (sim) 2.424.672.080.440.130.020.074.029.67
ThermoPower.Test.WaterComponents.ValveZeroFlow (sim) 0.424.261.990.180.260.010.053.777.15
ThermoPower.Test.WaterComponents.ValveZeroFlow2 (sim) 0.354.312.020.180.270.010.053.807.15
ThermoPower.Test.WaterComponents.WaterPump (sim) 0.604.271.910.160.260.010.053.807.27
ThermoPower.Test.WaterComponents.WaterPumpMech (sim) 0.604.302.030.180.290.010.053.777.40
ThermoPower.Test.WaterComponents.WaterPumps (sim) 1.584.951.930.430.120.020.074.318.94