Environment - simulationEnvironment: startTime=0 stopTime=3.1536e+07 tolerance=1e-06 numberOfIntervals=2500 stepSize=12614.4 Regular simulation: ./Buildings_8_Buildings.Obsolete.DistrictHeatingCooling.Validation.HeatingCoolingHotWaterSmall -abortSlowSimulation -alarm=480 -lv LOG_STATS LOG_STDOUT | info | ... loading "tab1" from "/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/Resources/Data/Obsolete/DistrictHeatingCooling/SubStations/VaporCompression/RefBldgLargeOfficeNew2004_7.1_5.0_3C_USA_CA_SAN_FRANCISCO.mos" LOG_STDOUT | info | ... loading "tab1" from "/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/Resources/Data/Obsolete/DistrictHeatingCooling/SubStations/VaporCompression/RefBldgStand-aloneRetailNew2004_7.1_5.0_3C_USA_CA_SAN_FRANCISCO.mos" LOG_STDOUT | info | ... loading "tab1" from "/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/Resources/Data/Obsolete/DistrictHeatingCooling/Plants/AlamedaOceanT.mos" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:352:3-361:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((larOff.pumHea.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:352:3-361:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((larOff.pumHotWat.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:352:3-361:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((larOff.pumChi.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:352:3-361:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((ret.pumHea.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:352:3-361:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((ret.pumHotWat.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:352:3-361:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((ret.pumChi.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/Fluid/Interfaces/PartialFourPortInterface.mo:30:3-31:84:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((ret.heaPumHotWat.m2_flow >= 0.0 and ret.heaPumHotWat.m2_flow <= 100000.0)) --> "Variable violating min/max constraint: 0.0 <= ret.heaPumHotWat.m2_flow <= 100000.0, has value: -2.42011e-36" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/Fluid/Interfaces/PartialFourPortInterface.mo:25:3-26:84:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((ret.chi.m1_flow >= 0.0 and ret.chi.m1_flow <= 100000.0)) --> "Variable violating min/max constraint: 0.0 <= ret.chi.m1_flow <= 100000.0, has value: -4.67527e-36" LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/Fluid/Interfaces/PartialFourPortInterface.mo:25:3-26:84:writable] | | | | The following assertion has been violated at time 6307.200000 | | | | ((larOff.chi.m1_flow >= 0.0 and larOff.chi.m1_flow <= 100000.0)) --> "Variable violating min/max constraint: 0.0 <= larOff.chi.m1_flow <= 100000.0, has value: -9.88131e-324" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/Fluid/Interfaces/PartialFourPortInterface.mo:30:3-31:84:writable] | | | | The following assertion has been violated at time 12614.400000 | | | | ((ret.heaPum.m2_flow >= 0.0 and ret.heaPum.m2_flow <= 100000.0)) --> "Variable violating min/max constraint: 0.0 <= ret.heaPum.m2_flow <= 100000.0, has value: -1.4822e-323" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/Fluid/Interfaces/PartialFourPortInterface.mo:30:3-31:84:writable] | | | | The following assertion has been violated at time 44150.400000 | | | | ((larOff.heaPum.m2_flow >= 0.0 and larOff.heaPum.m2_flow <= 100000.0)) --> "Variable violating min/max constraint: 0.0 <= larOff.heaPum.m2_flow <= 100000.0, has value: -6.93889e-17" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/Fluid/Interfaces.mo:13:5-14:68:writable] | | | | The following assertion has been violated at time 662256.000000 | | | | ((pla.sinHea.ports[1].m_flow >= 0.0 and pla.sinHea.ports[1].m_flow <= 100000.0)) --> "Variable violating min/max constraint: 0.0 <= pla.sinHea.ports[1].m_flow <= 100000.0, has value: -2.15e-08" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/Fluid/Interfaces/PartialFourPortInterface.mo:30:3-31:84:writable] | | | | The following assertion has been violated at time 662256.000000 | | | | ((pla.hea.m2_flow >= 0.0 and pla.hea.m2_flow <= 100000.0)) --> "Variable violating min/max constraint: 0.0 <= pla.hea.m2_flow <= 100000.0, has value: -2.15e-08" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/Fluid/Chillers/BaseClasses/Carnot.mo:121:3-123:56:writable] | | | | The following assertion has been violated at time 662256.000000 | | | | ((pla.hea.yPL >= 0.0)) --> "Variable violating min constraint: 0.0 <= pla.hea.yPL, has value: -1.38e-10" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/Fluid/Interfaces.mo:13:5-14:68:writable] | | | | The following assertion has been violated at time 13730774.400000 | | | | ((pla.sinCoo.ports[1].m_flow >= 0.0 and pla.sinCoo.ports[1].m_flow <= 100000.0)) --> "Variable violating min/max constraint: 0.0 <= pla.sinCoo.ports[1].m_flow <= 100000.0, has value: -0.000117927" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/Fluid/Interfaces/PartialFourPortInterface.mo:25:3-26:84:writable] | | | | The following assertion has been violated at time 13730774.400000 | | | | ((pla.coo.m1_flow >= 0.0 and pla.coo.m1_flow <= 100000.0)) --> "Variable violating min/max constraint: 0.0 <= pla.coo.m1_flow <= 100000.0, has value: -0.000117927" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/Fluid/Chillers/BaseClasses/Carnot.mo:121:3-123:56:writable] | | | | The following assertion has been violated at time 13730774.400000 | | | | ((pla.coo.yPL >= 0.0)) --> "Variable violating min constraint: 0.0 <= pla.coo.yPL, has value: -7.62208e-07" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/Fluid/Interfaces/StaticTwoPortConservationEquation.mo:144:5-152:68:writable] | | | | The following assertion has been violated at time 26931744.000000 | | | | ((noEvent(abs(ret.heaPum.eva.Q_flow) < 836800.0 * max(0.001 * ret.heaPum.eva.vol.steBal.m_flow_small, abs(ret.heaPum.m2_flow))))) --> "In HeatingCoolingHotWaterSmall.ret.heaPum.eva.vol.steBal: | | | | The heat flow rate equals 0.981732 W and the mass flow rate equals -2.38239e-07 kg/s, | | | | which results in a temperature difference 348.606 K > dTMax=200 K. | | | | This may indicate that energy is not conserved for small mass flow rates. | | | | The implementation may require prescribedHeatFlowRate = false." LOG_ASSERT | error | No event found, but assert was triggered. Throwing now!