Environment - simulationEnvironment: startTime=1.5552e+07 stopTime=1.56384e+07 tolerance=1e-07 numberOfIntervals=2500 stepSize=34.56 Regular simulation: ./Buildings_8_Buildings.Fluid.FMI.ExportContainers.Validation.RoomHVAC -abortSlowSimulation -alarm=480 -lv LOG_STATS LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:352:3-361:39:writable] | | | | The following assertion has been violated during initialization at time 15552000.000000 | | | | ((hvaCon2.fan.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:352:3-361:39:writable] | | | | The following assertion has been violated during initialization at time 15552000.000000 | | | | ((hvaCon2.fan2.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning." LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/Blocks/Interfaces.mo:329:5-330:56:writable] | | | | The following assertion has been violated at time 15552017.280000 | | | | ((hvaCon2.fan2.filter.y >= 0.0 and hvaCon2.fan2.filter.y <= 100000.0)) --> "Variable violating min/max constraint: 0.0 <= hvaCon2.fan2.filter.y <= 100000.0, has value: -7.22786e-24" LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.119887s reading init.xml | | | | | | 0.0088767s reading info.xml | | | | | | 0.000311845s [ 0.0%] pre-initialization | | | | | | 0.147761s [ 6.3%] initialization | | | | | | 0.000704271s [ 0.0%] steps | | | | | | 0.190832s [ 8.2%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 0.574978s [ 24.7%] event-handling | | | | | | 0.0479101s [ 2.1%] overhead | | | | | | 1.37s [ 58.7%] simulation | | | | | | 2.3325s [100.0%] total | | | | | events | | | | | | 289 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 24209 steps taken | | | | | | 30446 calls of functionODE | | | | | | 4350 evaluations of jacobian | | | | | | 473 error test failures | | | | | | 0 convergence test failures | | | | | | 0.705987s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.