Environment - simulationEnvironment: startTime=0 stopTime=360000 tolerance=1e-06 numberOfIntervals=2500 stepSize=144 Regular simulation: ./Buildings_8_Buildings.Experimental.DHC.EnergyTransferStations.Combined.Generation5.Validation.ChillerBorefield -abortSlowSimulation -alarm=480 -lv LOG_STATS LOG_STDOUT | info | ... loading "TStep" from "tmp/temperatureResponseMatrix/daf1e760b4b8bfc2ca0f78dd58b6acf6cf91586cTStep.mat" LOG_STDOUT | info | ... loading "TStep" from "tmp/temperatureResponseMatrix/daf1e760b4b8bfc2ca0f78dd58b6acf6cf91586cTStep.mat" LOG_STDOUT | info | ... loading "TStep" from "tmp/temperatureResponseMatrix/daf1e760b4b8bfc2ca0f78dd58b6acf6cf91586cTStep.mat" LOG_STDOUT | info | ... loading "TStep" from "tmp/temperatureResponseMatrix/daf1e760b4b8bfc2ca0f78dd58b6acf6cf91586cTStep.mat" LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/Fluid/Interfaces/PartialFourPortInterface.mo:30:3-31:84:writable] | | | | The following assertion has been violated at time 3840.000000 | | | | ((ets.hex.m2_flow >= 0.0 and ets.hex.m2_flow <= 100000.0)) --> "Variable violating min/max constraint: 0.0 <= ets.hex.m2_flow <= 100000.0, has value: -1.47445e-15" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/Experimental/DHC/Networks/BaseClasses/PartialDistribution2Pipe.mo:79:3-83:55:writable] | | | | The following assertion has been violated at time 28312.738701 | | | | ((ets.colHeaWat.mCon_flow[2] >= 0.0 and ets.colHeaWat.mCon_flow[2] <= 100000.0)) --> "Variable violating min/max constraint: 0.0 <= ets.colHeaWat.mCon_flow[2] <= 100000.0, has value: -2.2804e-19" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/Fluid/Interfaces/PartialFourPortInterface.mo:25:3-26:84:writable] | | | | The following assertion has been violated at time 29160.000000 | | | | ((ets.dHFloHeaWat.m1_flow >= 0.0 and ets.dHFloHeaWat.m1_flow <= 100000.0)) --> "Variable violating min/max constraint: 0.0 <= ets.dHFloHeaWat.m1_flow <= 100000.0, has value: -5.55112e-17" LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.223885s reading init.xml | | | | | | 0.0195365s reading info.xml | | | | | | 0.000507081s [ 0.0%] pre-initialization | | | | | | 16.6311s [ 33.1%] initialization | | | | | | 0.00417526s [ 0.0%] steps | | | | | | 2.84483s [ 5.7%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 2.59922s [ 5.2%] event-handling | | | | | | 0.225307s [ 0.4%] overhead | | | | | | 27.9525s [ 55.6%] simulation | | | | | | 50.2576s [100.0%] total | | | | | events | | | | | | 265 state events | | | | | | 6001 time events | | | | | solver: dassl | | | | | | 94140 steps taken | | | | | | 118615 calls of functionODE | | | | | | 67928 evaluations of jacobian | | | | | | 1194 error test failures | | | | | | 16 convergence test failures | | | | | | 25.7217s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.