Environment - simulationEnvironment: startTime=0 stopTime=864000 tolerance=1e-06 numberOfIntervals=240 stepSize=3600 Regular simulation: ./Buildings_3.0.0_Buildings.Obsolete.Air.Systems.SingleZone.VAV.Examples.Guideline36 -abortSlowSimulation -alarm=480 -lv LOG_STATS LOG_STDOUT | info | Using sparse solver for linear system 10, | | | | because density of 0.160 remains under threshold of 0.200. LOG_STDOUT | info | Using sparse solver for linear system 22, | | | | because density of 0.160 remains under threshold of 0.200. LOG_STDOUT | info | The maximum density for using sparse solvers can be specified | | | | using the runtime flag '<-lssMaxDensity=value>'. LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.0.0-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:417:3-427:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((false)) --> "*** Warning in Guideline36.hvac.pumChiWat: Mover has per.etaHydMet=.Power_VolumeFlowRate or per.etaHydMet=.EulerNumber. | | | | This requires per.pressure to be provided. | | | | Because it is not, the model overrides this setting by using per.etaHydMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.0.0-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:429:3-439:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((false)) --> "*** Warning in Guideline36.hvac.pumChiWat: Mover has per.etaMotMet=.Efficiency_MotorPartLoadRatio or per.etaMotMet=.GenericCurve. | | | | This requires per.WMot_nominal or per.pressure to be provided. Because neither is provided, | | | | the model overrides this setting and by using per.etaMotMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.0.0-master/Obsolete/Controls/OBC/ASHRAE/G36_PR1/AHUs/SingleZone/VAV/Economizers/Controller.mo:222:3-229:58:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((con.conEco.VOutMinSet_flow >= max(con.conEco.damLim.VOutMin_flow, max(0.0, con.conEco.VOutMin_flow)) and con.conEco.VOutMinSet_flow <= min(con.conEco.damLim.VOutDes_flow, con.conEco.VOutDes_flow))) --> "Variable violating min/max constraint: max(con.conEco.damLim.VOutMin_flow, max(0.0, con.conEco.VOutMin_flow)) <= con.conEco.VOutMinSet_flow <= min(con.conEco.damLim.VOutDes_flow, con.conEco.VOutDes_flow), has value: 0" LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.0.0-master/Fluid/Interfaces/PartialFourPortInterface.mo:23:3-24:84:writable] | | | | The following assertion has been violated at time 61871.489832 | | | | ((hvac.cooCoi.m1_flow >= 0.0 and hvac.cooCoi.m1_flow <= 100000.0)) --> "Variable violating min/max constraint: 0.0 <= hvac.cooCoi.m1_flow <= 100000.0, has value: -3.06559e-17" LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.184541s reading init.xml | | | | | | 0.0140052s reading info.xml | | | | | | 0.000488626s [ 0.0%] pre-initialization | | | | | | 0.034961s [ 0.5%] initialization | | | | | | 0.000395242s [ 0.0%] steps | | | | | | 0.418801s [ 6.5%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 1.05251s [ 16.3%] event-handling | | | | | | 0.0156911s [ 0.2%] overhead | | | | | | 4.91823s [ 76.4%] simulation | | | | | | 6.44108s [100.0%] total | | | | | events | | | | | | 268 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 27180 steps taken | | | | | | 45762 calls of functionODE | | | | | | 11362 evaluations of jacobian | | | | | | 2673 error test failures | | | | | | 1236 convergence test failures | | | | | | 3.78542s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.