Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr Buildings_3.0.0_Buildings.HeatTransfer.Examples.ConductorSingleLayerPCM.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_StateGraph2 2.0.2/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 3.0.0/package.mo", uses=false) Using package Buildings with version 3.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 3.0.0/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Using package Modelica_StateGraph2 with version 2.0.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_StateGraph2 2.0.2/package.mo) Running command: translateModel(Buildings.HeatTransfer.Examples.ConductorSingleLayerPCM,tolerance=1e-08,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_3.0.0_Buildings.HeatTransfer.Examples.ConductorSingleLayerPCM") translateModel(Buildings.HeatTransfer.Examples.ConductorSingleLayerPCM,tolerance=1e-08,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_3.0.0_Buildings.HeatTransfer.Examples.ConductorSingleLayerPCM") [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_StateGraph2 2.0.2/package.mo:257:38-257:110:writable] Warning: The file was not encoded in UTF-8: "

An important practical aspect of state machines is the abilit...". Defaulting to 7-bit ASCII with unknown characters replaced by '?'. To change encoding when loading a file: loadFile(encoding="ISO-XXXX-YY"). To change it in a package: add a file package.encoding at the top-level. Note: The Modelica Language Specification only allows files encoded in UTF-8. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_StateGraph2 2.0.2/package.mo:761:36-761:108:writable] Warning: The file was not encoded in UTF-8: "

The Modelica_StateGraph2 library is described in detail in (O...". Defaulting to 7-bit ASCII with unknown characters replaced by '?'. To change encoding when loading a file: loadFile(encoding="ISO-XXXX-YY"). To change it in a package: add a file package.encoding at the top-level. Note: The Modelica Language Specification only allows files encoded in UTF-8. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_StateGraph2 2.0.2/package.mo:1435:36-1435:108:writable] Warning: The file was not encoded in UTF-8: "

Main Authors:
SCode: time 0.4539/0.4561, allocations: 80.82 MB / 0.5904 GB, free: 22.28 MB / 446.1 MB Notification: Performance of NFInst.instantiate(Buildings.HeatTransfer.Examples.ConductorSingleLayerPCM): time 0.005512/0.4617, allocations: 4.423 MB / 0.5947 GB, free: 18.34 MB / 446.1 MB Notification: Performance of NFInst.instExpressions: time 0.004846/0.4666, allocations: 2.735 MB / 0.5974 GB, free: 15.62 MB / 446.1 MB Notification: Performance of NFInst.updateImplicitVariability: time 0.0005811/0.4672, allocations: 19.94 kB / 0.5974 GB, free: 15.6 MB / 446.1 MB Notification: Performance of NFTyping.typeComponents: time 0.001033/0.4682, allocations: 341.7 kB / 0.5977 GB, free: 15.26 MB / 446.1 MB Notification: Performance of NFTyping.typeBindings: time 0.0008591/0.4691, allocations: 445 kB / 0.5982 GB, free: 14.83 MB / 446.1 MB Notification: Performance of NFTyping.typeClassSections: time 0.001089/0.4702, allocations: 483.9 kB / 0.5986 GB, free: 14.36 MB / 446.1 MB Notification: Performance of NFFlatten.flatten: time 0.001231/0.4714, allocations: 1.589 MB / 0.6002 GB, free: 12.77 MB / 446.1 MB Notification: Performance of NFFlatten.resolveConnections: time 0.0002874/0.4717, allocations: 203.2 kB / 0.6004 GB, free: 12.55 MB / 446.1 MB Notification: Performance of NFEvalConstants.evaluate: time 0.0005401/0.4723, allocations: 0.5646 MB / 0.6009 GB, free: 11.99 MB / 446.1 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 3.0.0/HeatTransfer/Conduction/BaseClasses/temperature_u.mo:9:41-9:55:writable] Notification: From here: [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 3.0.0/HeatTransfer/Conduction/BaseClasses/temperature_u.mo:9:3-10:46:writable] Error: Non-array modification '"kg.K2/J"' for array component 'unit', possibly due to missing 'each'. Notification: Performance of FrontEnd: time 0.0006689/0.473, allocations: 0.5914 MB / 0.6015 GB, free: 11.39 MB / 446.1 MB