Environment - simulationEnvironment: startTime=0 stopTime=2 tolerance=1e-06 numberOfIntervals=2500 stepSize=0.0008 Regular simulation: ./Buildings_10_Buildings.Fluid.MixingVolumes.Validation.MixingVolumeZeroFlow -abortSlowSimulation -alarm=400 -emit_protected -lv LOG_STATS LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.1-maint.10.0.x/Fluid/MixingVolumes/BaseClasses/PartialMixingVolume.mo:134:5-139:3:writable] | | | | The following assertion has been violated at time 1.000400 | | | | (((-volQflow.ports[2].m_flow) > (-volNonLinSys.m_flow_small))) --> "In MixingVolumeZeroFlow.volNonLinSys: Model has flow reversal, | | | | but the parameter allowFlowReversal is set to false. | | | | m_flow_small = 0.0001 | | | | ports[1].m_flow = -0.0004 | | | | " LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.1-maint.10.0.x/Fluid/MixingVolumes/BaseClasses/PartialMixingVolume.mo:134:5-139:3:writable] | | | | The following assertion has been violated at time 1.000400 | | | | (((-volQflow.ports[2].m_flow) > (-volT.m_flow_small))) --> "In MixingVolumeZeroFlow.volT: Model has flow reversal, | | | | but the parameter allowFlowReversal is set to false. | | | | m_flow_small = 0.0001 | | | | ports[1].m_flow = -0.0004 | | | | " LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.1-maint.10.0.x/Fluid/MixingVolumes/BaseClasses/PartialMixingVolume.mo:134:5-139:3:writable] | | | | The following assertion has been violated at time 1.000400 | | | | (((-volQflow.ports[2].m_flow) > (-volLinSys.m_flow_small))) --> "In MixingVolumeZeroFlow.volLinSys: Model has flow reversal, | | | | but the parameter allowFlowReversal is set to false. | | | | m_flow_small = 0.0001 | | | | ports[1].m_flow = -0.0004 | | | | " LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.1-maint.10.0.x/Fluid/MixingVolumes/BaseClasses/PartialMixingVolume.mo:134:5-139:3:writable] | | | | The following assertion has been violated at time 1.000400 | | | | (((-volQflow.ports[2].m_flow) > (-volQflow.m_flow_small))) --> "In MixingVolumeZeroFlow.volQflow: Model has flow reversal, | | | | but the parameter allowFlowReversal is set to false. | | | | m_flow_small = 0.0001 | | | | ports[1].m_flow = -0.0004 | | | | " LOG_ASSERT | info | Found event, previous asserts are ignored. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.00562575s reading init.xml | | | | | | 0.000438543s reading info.xml | | | | | | 0.000496602s [ 1.8%] pre-initialization | | | | | | 0.000247174s [ 0.9%] initialization | | | | | | 2.865e-06s [ 0.0%] steps | | | | | | 8.532e-06s [ 0.0%] solver (excl. callbacks) | | | | | | 0.0012657s [ 4.5%] creating output-file | | | | | | 0.000416102s [ 1.5%] event-handling | | | | | | 0.00627651s [ 22.5%] overhead | | | | | | 0.019179s [ 68.8%] simulation | | | | | | 0.0278924s [100.0%] total | | | | | events | | | | | | 1 state events | | | | | | 0 time events | | | | | solver: euler | | | | | | 7502 steps taken | | | | | | 7502 calls of functionODE | | | | | | 0 evaluations of jacobian | | | | | | 0 error test failures | | | | | | 0 convergence test failures | | | | | | 0s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.