Environment - simulationEnvironment: startTime=0 stopTime=172800 tolerance=1e-06 numberOfIntervals=2500 stepSize=69.12 Regular simulation: ./Buildings_1.6_Buildings.ThermalZones.EnergyPlus_9_6_0.Validation.MultipleBuildings.TwoIdenticalOneZoneBuildings -abortSlowSimulation -alarm=480 -lv LOG_STATS EnergyPlus Starting EnergyPlus, Version 9.6.0-316f894e91, YMD=2024.05.18 10:55 Adjusting Air System Sizing Adjusting Standard 62.1 Ventilation Sizing Initializing Simulation Reporting Surfaces Beginning Primary Simulation Initializing New Environment Parameters Warming up {1} Warming up {2} Warming up {3} Warming up {4} Warming up {5} Warming up {6} Warming up {7} Warming up {8} Warming up {9} Warming up {10} Starting Simulation at 01/01/2017 for SPAWN-RUNPERIOD LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.0.0-master/Fluid/Interfaces/PartialTwoPortInterface.mo:20:3-21:81:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((bui[2].duc.m_flow >= 0.0 and bui[2].duc.m_flow <= 100000.0)) --> "Variable violating min/max constraint: 0.0 <= bui[2].duc.m_flow <= 100000.0, has value: -2.63739e-14" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.0.0-master/Fluid/Interfaces/PartialTwoPortInterface.mo:20:3-21:81:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((bui[1].duc.m_flow >= 0.0 and bui[1].duc.m_flow <= 100000.0)) --> "Variable violating min/max constraint: 0.0 <= bui[1].duc.m_flow <= 100000.0, has value: -2.63739e-14" LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0143399s reading init.xml | | | | | | 0.0012145s reading info.xml | | | | | | 7.9479e-05s [ 0.0%] pre-initialization | | | | | | 7.45765s [ 97.5%] initialization | | | | | | 6.242e-06s [ 0.0%] steps | | | | | | 0.00886691s [ 0.1%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 0.0933486s [ 1.2%] event-handling | | | | | | 0.00758292s [ 0.1%] overhead | | | | | | 0.0816779s [ 1.1%] simulation | | | | | | 7.64921s [100.0%] total | | | | | events | | | | | | 287 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 4740 steps taken | | | | | | 5582 calls of functionODE | | | | | | 4070 evaluations of jacobian | | | | | | 14 error test failures | | | | | | 0 convergence test failures | | | | | | 0.0287859s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully. Writing tabular output file results using HTML format. EnergyPlus Run Time=00hr 00min 0.45sec EnergyPlus Completed Successfully. double free or corruption (fasttop)