Environment - simulationEnvironment: startTime=0 stopTime=600 tolerance=1e-06 numberOfIntervals=2500 stepSize=0.24 Regular simulation: ./Buildings_1.6_Buildings.Obsolete.Fluid.Movers.Validation.ControlledFlowMachine -abortSlowSimulation -alarm=480 -lv LOG_STATS LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.0.0-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:98:3-98:83:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((fan1.eta >= 0.0)) --> "Variable violating min constraint: 0.0 <= fan1.eta, has value: -8.77205e-30" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.0.0-master/Fluid/Movers/BaseClasses/FlowMachineInterface.mo:311:3-315:28:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((fan1.eff.yMot >= 0.0)) --> "Variable violating min constraint: 0.0 <= fan1.eff.yMot, has value: -1.59547e-33" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.0.0-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:98:3-98:83:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((fan2.eta >= 0.0)) --> "Variable violating min constraint: 0.0 <= fan2.eta, has value: -3.25018e-27" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.0.0-master/Fluid/Movers/BaseClasses/FlowMachineInterface.mo:311:3-315:28:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((fan2.eff.yMot >= 0.0)) --> "Variable violating min constraint: 0.0 <= fan2.eff.yMot, has value: -5.91147e-31" LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.0.0-master/Obsolete/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:99:3-99:83:writable] | | | | The following assertion has been violated at time 60.000000 | | | | ((fan4.eta >= 0.0)) --> "Variable violating min constraint: 0.0 <= fan4.eta, has value: -2.09125e-10" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.0.0-master/Fluid/Movers/BaseClasses/FlowMachineInterface.mo:311:3-315:28:writable] | | | | The following assertion has been violated at time 60.000000 | | | | ((fan4.eff.yMot >= 0.0)) --> "Variable violating min constraint: 0.0 <= fan4.eff.yMot, has value: -3.80359e-14" LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0331252s reading init.xml | | | | | | 0.00300066s reading info.xml | | | | | | 0.000129984s [ 0.2%] pre-initialization | | | | | | 0.00192874s [ 2.3%] initialization | | | | | | 0.000102933s [ 0.1%] steps | | | | | | 0.00277491s [ 3.3%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 0.00149495s [ 1.8%] event-handling | | | | | | 0.0101898s [ 12.0%] overhead | | | | | | 0.068573s [ 80.5%] simulation | | | | | | 0.0851943s [100.0%] total | | | | | events | | | | | | 10 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 1073 steps taken | | | | | | 1411 calls of functionODE | | | | | | 203 evaluations of jacobian | | | | | | 34 error test failures | | | | | | 0 convergence test failures | | | | | | 0.00207176s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.