Environment - simulationEnvironment: startTime=0 stopTime=3.1536e+10 tolerance=1e-06 numberOfIntervals=2500 stepSize=1.26144e+07 Regular simulation: ./Buildings_1.6_Buildings.Fluid.Geothermal.Borefields.Validation.ConstantHeatInjection_100Boreholes -abortSlowSimulation -alarm=480 -lv LOG_STATS LOG_STDOUT | info | ... loading "TStep" from "tmp/temperatureResponseMatrix/3e232cf6fc83beff6017c44682a7c2f9170bab85TStep.mat" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.0.0-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:417:3-427:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((not (pum.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.Power_VolumeFlowRate or pum.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.EulerNumber))) --> "*** Warning in ConstantHeatInjection_100Boreholes.pum: Mover has per.etaHydMet=.Power_VolumeFlowRate or per.etaHydMet=.EulerNumber. | | | | This requires per.pressure to be provided. | | | | Because it is not, the model overrides this setting by using per.etaHydMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.0.0-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:429:3-439:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((pum.per.haveWMot_nominal or not (pum.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.Efficiency_MotorPartLoadRatio or pum.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.GenericCurve))) --> "*** Warning in ConstantHeatInjection_100Boreholes.pum: Mover has per.etaMotMet=.Efficiency_MotorPartLoadRatio or per.etaMotMet=.GenericCurve. | | | | This requires per.WMot_nominal or per.pressure to be provided. Because neither is provided, | | | | the model overrides this setting and by using per.etaMotMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve." LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.115931s reading init.xml | | | | | | 0.0103568s reading info.xml | | | | | | 0.000204243s [ 0.0%] pre-initialization | | | | | | 42.1857s [ 71.8%] initialization | | | | | | 0.00167388s [ 0.0%] steps | | | | | | 0.993191s [ 1.7%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 0.266224s [ 0.5%] event-handling | | | | | | 0.0920223s [ 0.2%] overhead | | | | | | 15.2271s [ 25.9%] simulation | | | | | | 58.7661s [100.0%] total | | | | | events | | | | | | 0 state events | | | | | | 8761 time events | | | | | solver: dassl | | | | | | 98118 steps taken | | | | | | 98413 calls of functionODE | | | | | | 89112 evaluations of jacobian | | | | | | 3 error test failures | | | | | | 0 convergence test failures | | | | | | 14.4434s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.