Environment - simulationEnvironment: startTime=0 stopTime=7200 tolerance=1e-06 numberOfIntervals=2500 stepSize=2.88 Regular simulation: ./AixLib_AixLib.Systems.ModularAHU.Examples.GenericAHU -abortSlowSimulation -alarm=480 -lv LOG_STATS LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 2.1.0/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:391:3-398:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((genericAHU.fanSup.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning in GenericAHU.genericAHU.fanSup: Mover is flow or pressure controlled and uses default pressure curve. | | | | This leads to an approximate power consumption. | | | | Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 2.1.0/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:391:3-398:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((genericAHU.fanRet.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning in GenericAHU.genericAHU.fanRet: Mover is flow or pressure controlled and uses default pressure curve. | | | | This leads to an approximate power consumption. | | | | Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 2.1.0/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:99:3-99:83:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((genericAHU.preheater.hydraulicModule.PumpInterface.pump.eta >= 0.0)) --> "Variable violating min constraint: 0.0 <= genericAHU.preheater.hydraulicModule.PumpInterface.pump.eta, has value: -2.89462e-12" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 2.1.0/Fluid/Movers/BaseClasses/PowerInterface.mo:46:3-47:27:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((genericAHU.preheater.hydraulicModule.PumpInterface.pump.heaDis.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= genericAHU.preheater.hydraulicModule.PumpInterface.pump.heaDis.etaHyd, has value: -4.34644e-09" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 2.1.0/Fluid/Movers/BaseClasses/FlowMachineInterface.mo:313:3-317:28:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((genericAHU.preheater.hydraulicModule.PumpInterface.pump.eff.yMot >= 0.0)) --> "Variable violating min constraint: 0.0 <= genericAHU.preheater.hydraulicModule.PumpInterface.pump.eff.yMot, has value: -3.38214e-14" LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 2.1.0/Fluid/Actuators/BaseClasses/ActuatorSignal.mo:31:3-33:69:writable] | | | | The following assertion has been violated at time 1.440000 | | | | ((genericAHU.cooler.hydraulicModule.valve.y_actual >= 0.0 and genericAHU.cooler.hydraulicModule.valve.y_actual <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= genericAHU.cooler.hydraulicModule.valve.y_actual <= 1.0, has value: -3.4655e-25" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 2.1.0/Fluid/Actuators/BaseClasses/ActuatorSignal.mo:31:3-33:69:writable] | | | | The following assertion has been violated at time 2.880000 | | | | ((genericAHU.preheater.hydraulicModule.valve.y_actual >= 0.0 and genericAHU.preheater.hydraulicModule.valve.y_actual <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= genericAHU.preheater.hydraulicModule.valve.y_actual <= 1.0, has value: -9.30694e-22" LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.238177s reading init.xml | | | | | | 0.023359s reading info.xml | | | | | | 0.000502192s [ 0.1%] pre-initialization | | | | | | 0.00309457s [ 0.4%] initialization | | | | | | 0.000106189s [ 0.0%] steps | | | | | | 0.0389325s [ 4.9%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 0.000470336s [ 0.1%] event-handling | | | | | | 0.114491s [ 14.3%] overhead | | | | | | 0.640514s [ 80.3%] simulation | | | | | | 0.79811s [100.0%] total | | | | | events | | | | | | 0 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 392 steps taken | | | | | | 599 calls of functionODE | | | | | | 57 evaluations of jacobian | | | | | | 12 error test failures | | | | | | 4 convergence test failures | | | | | | 0.0418415s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.