Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr AixLib_AixLib.Obsolete.YearIndependent.FastHVAC.Examples.Chiller.Chiller.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_DeviceDrivers 2.1.1/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/SDF master/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/package.mo", uses=false) Using package AixLib with version 1.3.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/package.mo) Using package SDF with version 0.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/SDF master/package.mo) Using package Modelica_DeviceDrivers with version 2.1.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_DeviceDrivers 2.1.1/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Running command: translateModel(AixLib.Obsolete.YearIndependent.FastHVAC.Examples.Chiller.Chiller,tolerance=1e-06,outputFormat="empty",numberOfIntervals=1000,variableFilter="",fileNamePrefix="AixLib_AixLib.Obsolete.YearIndependent.FastHVAC.Examples.Chiller.Chiller") translateModel(AixLib.Obsolete.YearIndependent.FastHVAC.Examples.Chiller.Chiller,tolerance=1e-06,outputFormat="empty",numberOfIntervals=1000,variableFilter="",fileNamePrefix="AixLib_AixLib.Obsolete.YearIndependent.FastHVAC.Examples.Chiller.Chiller") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.001386/0.001386, allocations: 108 kB / 15.6 MB, free: 132 kB / 14.72 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001796/0.001796, allocations: 192 kB / 16.53 MB, free: 6.391 MB / 14.72 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.445/1.445, allocations: 222.9 MB / 240.2 MB, free: 4.371 MB / 190.1 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_DeviceDrivers 2.1.1/package.mo): time 0.2242/0.2242, allocations: 12.01 MB / 302.4 MB, free: 0.8398 MB / 238.1 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/SDF master/package.mo): time 0.0005598/0.0005601, allocations: 27.95 kB / 355.5 MB, free: 3.746 MB / 286.1 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/Obsolete/YearIndependent/FastHVAC/Components/HeatExchangers/RadiatorMultiLayer.mo:265:34-265:6228:writable] Warning: Lexer treating \ as \\, since \ is not a valid Modelica escape sequence. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/Obsolete/YearIndependent/FastHVAC/Components/HeatExchangers/RadiatorMultiLayer.mo:265:34-265:6853:writable] Warning: Lexer treating \ as \\, since \ is not a valid Modelica escape sequence. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/Obsolete/YearIndependent/FastHVAC/Components/HeatExchangers/RadiatorMultiLayer.mo:265:34-265:8435:writable] Warning: Lexer treating \ as \\, since \ is not a valid Modelica escape sequence. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/Obsolete/YearIndependent/FastHVAC/Components/HeatExchangers/RadiatorMultiLayer.mo:265:34-265:9369:writable] Warning: Lexer treating \ as \\, since \ is not a valid Modelica escape sequence. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/Obsolete/YearIndependent/FastHVAC/Components/HeatExchangers/RadiatorMultiLayer.mo:265:34-265:11505:writable] Warning: Lexer treating \ as \\, since \ is not a valid Modelica escape sequence. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/Obsolete/YearIndependent/FastHVAC/Components/HeatExchangers/RadiatorMultiLayer.mo:265:34-265:12875:writable] Warning: Lexer treating \ as \\, since \ is not a valid Modelica escape sequence. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/ThermalZones/HighOrder/Components/Examples/DryAir/DryAir_test.mo:71:18-71:405:writable] Warning: Lexer treating \ as \\, since \ is not a valid Modelica escape sequence. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/ThermalZones/HighOrder/Components/DryAir/InfiltrationRate_DIN12831.mo:20:192-20:2066:writable] Warning: Lexer treating \ as \\, since \ is not a valid Modelica escape sequence. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/ThermalZones/HighOrder/Components/DryAir/InfiltrationRate_DIN12831.mo:20:192-20:4252:writable] Warning: Lexer treating \ as \\, since \ is not a valid Modelica escape sequence. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/DataBase/Weather/SurfaceOrientation/SurfaceOrientationData_N_E_S_W_RoofN_Roof_S.mo:5:35-5:362:writable] Warning: Lexer treating \ as \\, since \ is not a valid Modelica escape sequence. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/DataBase/Weather/SurfaceOrientation/SurfaceOrientationData_N_E_S_W_Hor.mo:5:35-5:320:writable] Warning: Lexer treating \ as \\, since \ is not a valid Modelica escape sequence. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/DataBase/Weather/SurfaceOrientation/SurfaceOrientationData_NE_SE_SW_NW_Hor.mo:5:35-5:324:writable] Warning: Lexer treating \ as \\, since \ is not a valid Modelica escape sequence. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/DataBase/CHP/CHPDataSimple/CHP_XRGI_9kWel.mo:25:34-25:588:writable] Warning: Lexer treating \ as \\, since \ is not a valid Modelica escape sequence. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/DataBase/CHP/CHPDataSimple/CHP_XRGI_9kWel.mo:25:34-25:3852:writable] Warning: Lexer treating \ as \\, since \ is not a valid Modelica escape sequence. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/DataBase/CHP/CHPDataSimple/CHP_Cleanergy_C9G.mo:36:34-36:594:writable] Warning: Lexer treating \ as \\, since \ is not a valid Modelica escape sequence. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/BoundaryConditions/InternalGains/Examples/InternalGains/Machines.mo:31:20-31:400:writable] Warning: Lexer treating \ as \\, since \ is not a valid Modelica escape sequence. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/BoundaryConditions/InternalGains/Examples/InternalGains/Lights.mo:27:20-27:398:writable] Warning: Lexer treating \ as \\, since \ is not a valid Modelica escape sequence. Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/package.mo): time 2.003/2.003, allocations: 268.1 MB / 0.6608 GB, free: 0.7188 MB / 462.1 MB Notification: Performance of FrontEnd - loaded program: time 0.002343/0.002343, allocations: 111.9 kB / 0.7801 GB, free: 32.71 MB / 0.545 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2923/0.2946, allocations: 108.4 MB / 0.8859 GB, free: 1.344 MB / 0.5919 GB Notification: Performance of NFInst.instantiate(AixLib.Obsolete.YearIndependent.FastHVAC.Examples.Chiller.Chiller): time 0.01252/0.3072, allocations: 9.464 MB / 0.8952 GB, free: 7.816 MB / 0.6075 GB Notification: Performance of NFInst.instExpressions: time 0.007791/0.315, allocations: 3.924 MB / 0.899 GB, free: 3.887 MB / 0.6075 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/Obsolete/YearIndependent/FastHVAC/Components/Chiller/Chiller.mo:71:3-76:26:writable] Warning: Parameter GConIns has annotation(Evaluate=true) and no binding. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/Obsolete/YearIndependent/FastHVAC/Components/Chiller/Chiller.mo:104:3-109:26:writable] Warning: Parameter GEvaIns has annotation(Evaluate=true) and no binding. Notification: Performance of NFInst.updateImplicitVariability: time 0.003128/0.3182, allocations: 43.81 kB / 0.899 GB, free: 3.844 MB / 0.6075 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/Obsolete/YearIndependent/FastHVAC/Components/Sensors/TemperatureSensor.mo:16:3-18:59:writable] Warning: Connector enthalpyPort_a is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/Obsolete/YearIndependent/FastHVAC/Components/Sensors/TemperatureSensor.mo:19:3-21:57:writable] Warning: Connector enthalpyPort_b is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/Obsolete/YearIndependent/FastHVAC/Components/Pumps/FluidSource.mo:21:3-24:57:writable] Warning: Connector enthalpyPort_b is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/Obsolete/YearIndependent/FastHVAC/Components/Chiller/Chiller.mo:149:5-152:72:writable] Warning: Connector enthalpyPort_a is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/Obsolete/YearIndependent/FastHVAC/Components/Chiller/Chiller.mo:153:3-156:70:writable] Warning: Connector enthalpyPort_b is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/Obsolete/YearIndependent/FastHVAC/Components/Chiller/Chiller.mo:157:3-160:72:writable] Warning: Connector enthalpyPort_a1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/Obsolete/YearIndependent/FastHVAC/Components/Chiller/Chiller.mo:161:3-164:74:writable] Warning: Connector enthalpyPort_b1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/Obsolete/YearIndependent/FastHVAC/Interfaces/TwoPortHeatMassExchanger.mo:18:5-20:71:writable] Warning: Connector enthalpyPort_a is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/Obsolete/YearIndependent/FastHVAC/Interfaces/TwoPortHeatMassExchanger.mo:21:5-23:69:writable] Warning: Connector enthalpyPort_b is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/Obsolete/YearIndependent/FastHVAC/BaseClasses/EnergyBalance.mo:4:3-7:59:writable] Warning: Connector enthalpyPort_a is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/Obsolete/YearIndependent/FastHVAC/BaseClasses/EnergyBalance.mo:8:3-11:57:writable] Warning: Connector enthalpyPort_b is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/Obsolete/YearIndependent/FastHVAC/BaseClasses/WorkingFluid.mo:13:3-15:71:writable] Warning: Connector enthalpyPort_b is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/Obsolete/YearIndependent/FastHVAC/BaseClasses/WorkingFluid.mo:16:3-18:73:writable] Warning: Connector enthalpyPort_a is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/Obsolete/YearIndependent/FastHVAC/Interfaces/TwoPortHeatMassExchanger.mo:18:5-20:71:writable] Warning: Connector enthalpyPort_a is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/Obsolete/YearIndependent/FastHVAC/Interfaces/TwoPortHeatMassExchanger.mo:21:5-23:69:writable] Warning: Connector enthalpyPort_b is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/Obsolete/YearIndependent/FastHVAC/BaseClasses/EnergyBalance.mo:4:3-7:59:writable] Warning: Connector enthalpyPort_a is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/Obsolete/YearIndependent/FastHVAC/BaseClasses/EnergyBalance.mo:8:3-11:57:writable] Warning: Connector enthalpyPort_b is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/Obsolete/YearIndependent/FastHVAC/BaseClasses/WorkingFluid.mo:13:3-15:71:writable] Warning: Connector enthalpyPort_b is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/Obsolete/YearIndependent/FastHVAC/BaseClasses/WorkingFluid.mo:16:3-18:73:writable] Warning: Connector enthalpyPort_a is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/Obsolete/YearIndependent/FastHVAC/Components/Sensors/TemperatureSensor.mo:16:3-18:59:writable] Warning: Connector enthalpyPort_a is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/Obsolete/YearIndependent/FastHVAC/Components/Sensors/TemperatureSensor.mo:19:3-21:57:writable] Warning: Connector enthalpyPort_b is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/Obsolete/YearIndependent/FastHVAC/Components/Sensors/TemperatureSensor.mo:16:3-18:59:writable] Warning: Connector enthalpyPort_a is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/Obsolete/YearIndependent/FastHVAC/Components/Sensors/TemperatureSensor.mo:19:3-21:57:writable] Warning: Connector enthalpyPort_b is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/Obsolete/YearIndependent/FastHVAC/Components/Sensors/MassFlowSensor.mo:14:3-16:59:writable] Warning: Connector enthalpyPort_a is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/Obsolete/YearIndependent/FastHVAC/Components/Sensors/MassFlowSensor.mo:17:3-19:57:writable] Warning: Connector enthalpyPort_b is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/Obsolete/YearIndependent/FastHVAC/Components/Sensors/TemperatureSensor.mo:16:3-18:59:writable] Warning: Connector enthalpyPort_a is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/Obsolete/YearIndependent/FastHVAC/Components/Sensors/TemperatureSensor.mo:19:3-21:57:writable] Warning: Connector enthalpyPort_b is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/Obsolete/YearIndependent/FastHVAC/Components/Sensors/TemperatureSensor.mo:16:3-18:59:writable] Warning: Connector enthalpyPort_a is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/Obsolete/YearIndependent/FastHVAC/Components/Sensors/TemperatureSensor.mo:19:3-21:57:writable] Warning: Connector enthalpyPort_b is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/Obsolete/YearIndependent/FastHVAC/Components/Sensors/MassFlowSensor.mo:14:3-16:59:writable] Warning: Connector enthalpyPort_a is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/Obsolete/YearIndependent/FastHVAC/Components/Sensors/MassFlowSensor.mo:17:3-19:57:writable] Warning: Connector enthalpyPort_b is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/Obsolete/YearIndependent/FastHVAC/Components/Sinks/Vessel.mo:9:3-11:41:writable] Warning: Connector enthalpyPort_a is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/Obsolete/YearIndependent/FastHVAC/BaseClasses/EnergyBalance.mo:4:3-7:59:writable] Warning: Connector enthalpyPort_a is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/Obsolete/YearIndependent/FastHVAC/BaseClasses/EnergyBalance.mo:8:3-11:57:writable] Warning: Connector enthalpyPort_b is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/Obsolete/YearIndependent/FastHVAC/BaseClasses/WorkingFluid.mo:13:3-15:71:writable] Warning: Connector enthalpyPort_b is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/Obsolete/YearIndependent/FastHVAC/BaseClasses/WorkingFluid.mo:16:3-18:73:writable] Warning: Connector enthalpyPort_a is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/Obsolete/YearIndependent/FastHVAC/Components/Pumps/Pump.mo:30:3-33:59:writable] Warning: Connector enthalpyPort_a is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/Obsolete/YearIndependent/FastHVAC/Components/Pumps/Pump.mo:34:3-37:57:writable] Warning: Connector enthalpyPort_b is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). Notification: Performance of NFTyping.typeComponents: time 0.002423/0.3207, allocations: 0.8651 MB / 0.8999 GB, free: 2.98 MB / 0.6075 GB Notification: Performance of NFTyping.typeBindings: time 0.002404/0.3231, allocations: 0.6514 MB / 0.9005 GB, free: 2.324 MB / 0.6075 GB Notification: Performance of NFTyping.typeClassSections: time 0.002236/0.3253, allocations: 0.9623 MB / 0.9015 GB, free: 1.379 MB / 0.6075 GB Notification: Performance of NFFlatten.flatten: time 0.003564/0.3289, allocations: 2.58 MB / 0.904 GB, free: 14.79 MB / 0.6232 GB Notification: Performance of NFFlatten.resolveConnections: time 0.002001/0.3309, allocations: 1.504 MB / 0.9055 GB, free: 13.23 MB / 0.6232 GB Notification: Performance of NFEvalConstants.evaluate: time 0.001209/0.3322, allocations: 0.8214 MB / 0.9063 GB, free: 12.41 MB / 0.6232 GB Notification: Performance of NFSimplifyModel.simplify: time 0.0009732/0.3331, allocations: 0.8906 MB / 0.9071 GB, free: 11.52 MB / 0.6232 GB Notification: Performance of NFPackage.collectConstants: time 0.0002856/0.3334, allocations: 248 kB / 0.9074 GB, free: 11.27 MB / 0.6232 GB Notification: Performance of NFFlatten.collectFunctions: time 0.000476/0.3339, allocations: 295.9 kB / 0.9076 GB, free: 10.98 MB / 0.6232 GB Notification: Performance of NFScalarize.scalarize: time 0.0005956/0.3345, allocations: 0.7712 MB / 0.9084 GB, free: 10.21 MB / 0.6232 GB Notification: Performance of NFVerifyModel.verify: time 0.001245/0.3358, allocations: 1.392 MB / 0.9098 GB, free: 8.812 MB / 0.6232 GB Notification: Performance of NFConvertDAE.convert: time 0.004029/0.3398, allocations: 4.502 MB / 0.9142 GB, free: 4.297 MB / 0.6232 GB Notification: Performance of FrontEnd - DAE generated: time 6.032e-06/0.3398, allocations: 0 / 0.9142 GB, free: 4.297 MB / 0.6232 GB Notification: Performance of FrontEnd: time 3.567e-06/0.3398, allocations: 0 / 0.9142 GB, free: 4.297 MB / 0.6232 GB Notification: Performance of Transformations before backend: time 7.716e-05/0.3399, allocations: 3.938 kB / 0.9142 GB, free: 4.293 MB / 0.6232 GB Error: Too few equations, under-determined system. The model has 386 equation(s) and 387 variable(s).