/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --tempDir=temp_TransiEnt_TransiEnt_Components_Heat_Check_TestPipeGasAdvanced_fmu --startTime=0 --stopTime=1200 --timeout=50 --tolerance=1e-05 TransiEnt_TransiEnt_Components_Heat_Check_TestPipeGasAdvanced.fmu LOG_STDOUT | info | >> Looking for file: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master//Tables//ambient/UndergroundTemperature_Duesseldorf_1m_2017.txt LOG_STDOUT | info | >> Calling File: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Tables/ambient/UndergroundTemperature_Duesseldorf_1m_2017.txt LOG_STDOUT | info | ... loading "default" from "/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Tables/ambient/UndergroundTemperature_Duesseldorf_1m_2017.txt" LOG_STDOUT | info | >> Looking for file: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master//Tables/electricity/ElectricityPrices_DayAhead_EPEX_Spot_2011.txt LOG_STDOUT | info | >> Calling File: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Tables/electricity/ElectricityPrices_DayAhead_EPEX_Spot_2011.txt LOG_STDOUT | info | ... loading "default" from "/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Tables/electricity/ElectricityPrices_DayAhead_EPEX_Spot_2011.txt" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Basics/ControlVolumes/Fundamentals/HeatTransport/Generic_HT/HeatTransfer_L4.mo:27:3-27:147:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((pipe.airVolume.heatTransferInner.A_heat[3] >= 0.0)) --> "Variable violating min constraint: 0.0 <= pipe.airVolume.heatTransferInner.A_heat[3], has value: -1" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Basics/ControlVolumes/Fundamentals/HeatTransport/Generic_HT/HeatTransfer_L4.mo:27:3-27:147:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((pipe.airVolume.heatTransferInner.A_heat[2] >= 0.0)) --> "Variable violating min constraint: 0.0 <= pipe.airVolume.heatTransferInner.A_heat[2], has value: -1" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Basics/ControlVolumes/Fundamentals/HeatTransport/Generic_HT/HeatTransfer_L4.mo:27:3-27:147:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((pipe.airVolume.heatTransferInner.A_heat[1] >= 0.0)) --> "Variable violating min constraint: 0.0 <= pipe.airVolume.heatTransferInner.A_heat[1], has value: -1" warning: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/TransiEnt_TransiEnt.Components.Heat.Check.TestPipeGasAdvanced/temp_TransiEnt_TransiEnt_Components_Heat_Check_TestPipeGasAdvanced_fmu/model-xgauozej/temp/0001_TransiEnt_TransiEnt_Components_Heat_Check_TestPipeGasAdvanced (logStatusWarning): The following assertion has been violated during initialization at time 0.000000 LOG_ASSERT | debug | Model error: Argument of sqrt(pipe.airVolume.pressureLoss.zeta[3] * pipe.airVolume.pressureLoss.rho[3]) was -1.24912e-05 should be >= 0 LOG_STDOUT | warning | Non-Linear Solver try to handle a problem with a called assert. warning: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/TransiEnt_TransiEnt.Components.Heat.Check.TestPipeGasAdvanced/temp_TransiEnt_TransiEnt_Components_Heat_Check_TestPipeGasAdvanced_fmu/model-xgauozej/temp/0001_TransiEnt_TransiEnt_Components_Heat_Check_TestPipeGasAdvanced (logStatusWarning): The following assertion has been violated during initialization at time 0.000000 LOG_ASSERT | debug | Model error: Argument of sqrt(pipe.airVolume.pressureLoss.zeta[3] * pipe.airVolume.pressureLoss.rho[3]) was -1.24912e-05 should be >= 0 warning: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/TransiEnt_TransiEnt.Components.Heat.Check.TestPipeGasAdvanced/temp_TransiEnt_TransiEnt_Components_Heat_Check_TestPipeGasAdvanced_fmu/model-xgauozej/temp/0001_TransiEnt_TransiEnt_Components_Heat_Check_TestPipeGasAdvanced (logStatusWarning): The following assertion has been violated during initialization at time 0.000000 LOG_ASSERT | debug | Model error: Argument of sqrt(pipe.airVolume.pressureLoss.zeta[3] * pipe.airVolume.pressureLoss.rho[3]) was -1.24912e-05 should be >= 0 warning: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/TransiEnt_TransiEnt.Components.Heat.Check.TestPipeGasAdvanced/temp_TransiEnt_TransiEnt_Components_Heat_Check_TestPipeGasAdvanced_fmu/model-xgauozej/temp/0001_TransiEnt_TransiEnt_Components_Heat_Check_TestPipeGasAdvanced (logStatusWarning): The following assertion has been violated during initialization at time 0.000000 LOG_ASSERT | debug | Model error: Argument of sqrt(pipe.airVolume.pressureLoss.zeta[3] * pipe.airVolume.pressureLoss.rho[3]) was -1.24912e-05 should be >= 0 LOG_ASSERT | debug | Solving non-linear system 370 failed at time=0. | | | | For more information please use -lv LOG_NLS. LOG_ASSERT | error | Failed to solve the initialization problem with global homotopy with equidistant step size. LOG_ASSERT | debug | Unable to solve initialization problem. error: [fmi2logger] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/TransiEnt_TransiEnt.Components.Heat.Check.TestPipeGasAdvanced/temp_TransiEnt_TransiEnt_Components_Heat_Check_TestPipeGasAdvanced_fmu/model-xgauozej/temp/0001_TransiEnt_TransiEnt_Components_Heat_Check_TestPipeGasAdvanced (logFmi2Call): fmi2EnterInitializationMode: terminated by an assertion. error: [initialize] fmi2_import_exit_initialization_mode failed for FMU "model.root.TransiEnt_TransiEnt_Components_Heat_Check_TestPipeGasAdvanced" error: [initialize] Initialization of system "model.root" failed error: [simulate] Model "model" is in wrong model state info: 4 warnings info: 4 errors