Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr ThermoSysPro_ThermoSysPro.Fluid.Examples.Book.SimpleExamples.HeatExchanger.DynamicWaterHeater.ZeroFlow.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/package.mo", uses=false) Using package ThermoSysPro with version 4.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/package.mo) Running command: "" <> buildModelFMU(ThermoSysPro.Fluid.Examples.Book.SimpleExamples.HeatExchanger.DynamicWaterHeater.ZeroFlow,fileNamePrefix="ThermoSysPro_ThermoSysPro_Fluid_Examples_Book_SimpleExamples_HeatExchanger_DynamicWaterHeater_ZeroFlow",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(ThermoSysPro.Fluid.Examples.Book.SimpleExamples.HeatExchanger.DynamicWaterHeater.ZeroFlow,fileNamePrefix="ThermoSysPro_ThermoSysPro_Fluid_Examples_Book_SimpleExamples_HeatExchanger_DynamicWaterHeater_ZeroFlow",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/package.mo): time 0.8124/0.8124, allocations: 150.9 MB / 166.4 MB, free: 14.18 MB / 142.1 MB Notification: Performance of FrontEnd - loaded program: time 0.0003676/0.0003677, allocations: 11.97 kB / 204.7 MB, free: 9.484 MB / 174.1 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1669/0.1673, allocations: 31.34 MB / 236 MB, free: 5.434 MB / 190.1 MB Notification: Automatically loaded package Complex 4.0.0 due to uses annotation from Modelica. Notification: Automatically loaded package ModelicaServices 4.0.0 due to uses annotation from Modelica. Notification: Automatically loaded package Modelica 4.0.0 due to usage. Notification: Performance of NFInst.instantiate(ThermoSysPro.Fluid.Examples.Book.SimpleExamples.HeatExchanger.DynamicWaterHeater.ZeroFlow): time 1.685/1.852, allocations: 309.3 MB / 0.5325 GB, free: 14.66 MB / 430.1 MB Notification: Performance of NFInst.instExpressions: time 0.5951/2.447, allocations: 205.1 MB / 0.7328 GB, free: 1.953 MB / 0.5762 GB Notification: Performance of NFInst.updateImplicitVariability: time 0.004334/2.452, allocations: 84.53 kB / 0.7329 GB, free: 1.953 MB / 0.5762 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/BoundaryConditions/SourceP.mo:58:3-59:65:writable] Warning: Connector C is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/BoundaryConditions/SinkP.mo:46:3-47:67:writable] Warning: Connector C is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/ControlValve.mo:44:3-45:68:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/ControlValve.mo:46:3-47:66:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/TwoPhaseCavity.mo:182:3-184:57:writable] Warning: Connector Cv is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/TwoPhaseCavity.mo:185:3-187:61:writable] Warning: Connector Cl is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/TwoPhaseCavity.mo:200:3-201:67:writable] Warning: Connector Ce is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicOnePhaseFlowPipe.mo:150:3-151:67:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicOnePhaseFlowPipe.mo:152:3-153:65:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicWaterHeater.mo:98:3-99:65:writable] Warning: Connector C1vap is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicWaterHeater.mo:100:3-102:16:writable] Warning: Connector C2ex is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicWaterHeater.mo:103:3-104:76:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicWaterHeater.mo:105:3-106:74:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicWaterHeater.mo:111:3-112:74:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicOnePhaseFlowPipe.mo:150:3-151:67:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicOnePhaseFlowPipe.mo:152:3-153:65:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicOnePhaseFlowPipe.mo:150:3-151:67:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicOnePhaseFlowPipe.mo:152:3-153:65:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeC.mo:103:3-105:59:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeC.mo:106:3-108:57:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeC.mo:109:3-110:65:writable] Warning: Connector Cs is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeC.mo:111:3-113:24:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeD.mo:104:3-105:67:writable] Warning: Connector Ce is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeD.mo:106:3-107:73:writable] Warning: Connector Cs1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeD.mo:108:3-109:75:writable] Warning: Connector Cs2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeD.mo:110:3-111:71:writable] Warning: Connector Cs3 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeD.mo:104:3-105:67:writable] Warning: Connector Ce is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeD.mo:106:3-107:73:writable] Warning: Connector Cs1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeD.mo:108:3-109:75:writable] Warning: Connector Cs2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeD.mo:110:3-111:71:writable] Warning: Connector Cs3 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/BoundaryConditions/Sink.mo:39:3-40:67:writable] Warning: Connector C is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/SingularPressureLoss.mo:27:3-28:67:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/SingularPressureLoss.mo:29:3-30:65:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/SingularPressureLoss.mo:27:3-28:67:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/SingularPressureLoss.mo:29:3-30:65:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/BoundaryConditions/SourceP.mo:58:3-59:65:writable] Warning: Connector C is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/BoundaryConditions/RefQ.mo:10:3-11:67:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/BoundaryConditions/RefQ.mo:12:3-13:65:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/IdealCheckValve.mo:22:3-23:65:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/IdealCheckValve.mo:24:3-25:67:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/SingularPressureLoss.mo:27:3-28:67:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/SingularPressureLoss.mo:29:3-30:65:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/LumpedStraightPipe.mo:54:3-55:67:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/LumpedStraightPipe.mo:56:3-57:65:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). Notification: Performance of NFTyping.typeComponents: time 0.002783/2.455, allocations: 0.9373 MB / 0.7338 GB, free: 1.949 MB / 0.5762 GB Notification: Performance of NFTyping.typeBindings: time 0.006473/2.461, allocations: 2.253 MB / 0.736 GB, free: 1.863 MB / 0.5762 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Properties/WaterSteam/IF97_packages.mo:783:9-783:27:writable] Warning: cv was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Properties/WaterSteam/IF97_packages.mo:850:9-850:27:writable] Warning: cv was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Properties/WaterSteam/IF97_packages.mo:1088:9-1088:27:writable] Warning: cv was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Properties/WaterSteamSimple/prop4_Ph.mo:69:3-69:60:writable] Warning: dh1satp was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Properties/WaterSteamSimple/prop4_Ph.mo:69:3-69:60:writable] Warning: dh2satp was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Properties/WaterSteamSimple/prop4_Ph_der.mo:167:3-170:49:writable] Warning: du1satp_der was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Properties/WaterSteamSimple/prop4_Ph_der.mo:167:3-170:49:writable] Warning: du2satp_der was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Properties/Fluid/derDensity_derP_derh.mo:63:5-63:84:writable] Warning: T was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. Notification: Performance of NFTyping.typeClassSections: time 0.04643/2.507, allocations: 17.08 MB / 0.7527 GB, free: 1.504 MB / 0.5762 GB Notification: Performance of NFFlatten.flatten: time 0.02715/2.535, allocations: 31.3 MB / 0.7833 GB, free: 5.883 MB / 0.5919 GB Notification: Performance of NFFlatten.resolveConnections: time 0.01706/2.552, allocations: 11.06 MB / 0.7941 GB, free: 13.87 MB / 0.6075 GB Notification: Performance of NFEvalConstants.evaluate: time 0.01861/2.57, allocations: 9.004 MB / 0.8029 GB, free: 5.453 MB / 0.6075 GB Notification: Performance of NFSimplifyModel.simplify: time 0.01793/2.588, allocations: 10.81 MB / 0.8134 GB, free: 11.07 MB / 0.6231 GB Notification: Performance of NFPackage.collectConstants: time 0.008608/2.597, allocations: 2.827 MB / 0.8162 GB, free: 8.246 MB / 0.6231 GB Notification: Performance of NFFlatten.collectFunctions: time 0.05943/2.656, allocations: 26.79 MB / 0.8423 GB, free: 14.25 MB / 0.6544 GB Notification: Performance of NFScalarize.scalarize: time 0.01307/2.67, allocations: 8 MB / 0.8502 GB, free: 6.379 MB / 0.6544 GB Notification: Performance of NFVerifyModel.verify: time 0.02333/2.693, allocations: 9.796 MB / 0.8597 GB, free: 12.7 MB / 0.67 GB Notification: Performance of NFConvertDAE.convert: time 0.06705/2.76, allocations: 38.8 MB / 0.8976 GB, free: 7.594 MB / 0.7012 GB Notification: Performance of FrontEnd - DAE generated: time 7.033e-06/2.76, allocations: 3.938 kB / 0.8976 GB, free: 7.59 MB / 0.7012 GB Notification: Performance of FrontEnd: time 1.723e-06/2.76, allocations: 0 / 0.8976 GB, free: 7.59 MB / 0.7012 GB Notification: Performance of Transformations before backend: time 0.0007438/2.761, allocations: 0 / 0.8976 GB, free: 7.59 MB / 0.7012 GB Notification: Model statistics after passing the front-end and creating the data structures used by the back-end: * Number of equations: 3466 * Number of variables: 3466 Notification: Performance of Generate backend data structure: time 0.07348/2.834, allocations: 18.11 MB / 0.9153 GB, free: 5.406 MB / 0.7169 GB Notification: Performance of prepare preOptimizeDAE: time 4.717e-05/2.834, allocations: 8.031 kB / 0.9153 GB, free: 5.398 MB / 0.7169 GB Notification: Performance of preOpt introduceOutputAliases (simulation): time 0.0077/2.842, allocations: 1.804 MB / 0.9171 GB, free: 3.582 MB / 0.7169 GB Notification: Performance of preOpt normalInlineFunction (simulation): time 0.008695/2.851, allocations: 1.418 MB / 0.9185 GB, free: 2.148 MB / 0.7169 GB Notification: Performance of preOpt evaluateParameters (simulation): time 0.01954/2.87, allocations: 7.133 MB / 0.9254 GB, free: 11.31 MB / 0.7325 GB Notification: Performance of preOpt simplifyIfEquations (simulation): time 0.004995/2.875, allocations: 3.342 MB / 0.9287 GB, free: 7.469 MB / 0.7325 GB Notification: Performance of preOpt expandDerOperator (simulation): time 0.009575/2.885, allocations: 1.417 MB / 0.9301 GB, free: 6.055 MB / 0.7325 GB Notification: Performance of preOpt clockPartitioning (simulation): time 0.06914/2.954, allocations: 26.12 MB / 0.9556 GB, free: 10.96 MB / 0.7637 GB Notification: Performance of preOpt findStateOrder (simulation): time 0.0006428/2.955, allocations: 50.19 kB / 0.9556 GB, free: 10.95 MB / 0.7637 GB Notification: Performance of preOpt replaceEdgeChange (simulation): time 0.006708/2.962, allocations: 0.5625 MB / 0.9562 GB, free: 10.38 MB / 0.7637 GB Notification: Performance of preOpt inlineArrayEqn (simulation): time 0.0003461/2.962, allocations: 356 kB / 0.9565 GB, free: 10.04 MB / 0.7637 GB Notification: Performance of preOpt removeEqualRHS (simulation): time 0.5151/3.477, allocations: 68.34 MB / 1.023 GB, free: 376 MB / 0.7794 GB Warning: The model contains alias variables with redundant start and/or conflicting nominal values. It is recommended to resolve the conflicts, because otherwise the system could be hard to solve. To print the conflicting alias sets and the chosen candidates please use -d=aliasConflicts. Notification: Performance of preOpt removeSimpleEquations (simulation): time 0.2267/3.704, allocations: 140.8 MB / 1.161 GB, free: 241.1 MB / 0.7794 GB Notification: Performance of preOpt comSubExp (simulation): time 0.08276/3.787, allocations: 33.82 MB / 1.194 GB, free: 207.8 MB / 0.7794 GB Notification: Performance of preOpt resolveLoops (simulation): time 0.02685/3.814, allocations: 12.89 MB / 1.206 GB, free: 194.8 MB / 0.7794 GB Notification: Performance of preOpt evalFunc (simulation): time 1.439/5.253, allocations: 0.5608 GB / 1.767 GB, free: 374.4 MB / 0.7794 GB Notification: Performance of preOpt encapsulateWhenConditions (simulation): time 0.03269/5.286, allocations: 14.53 MB / 1.781 GB, free: 373.8 MB / 0.7794 GB Notification: Performance of pre-optimization done (n=1629): time 4.314e-05/5.286, allocations: 4.547 kB / 1.781 GB, free: 373.8 MB / 0.7794 GB Notification: Performance of matching and sorting (n=1630): time 0.5213/5.807, allocations: 132.3 MB / 1.911 GB, free: 271.3 MB / 0.7794 GB Notification: Performance of inlineWhenForInitialization (initialization): time 0.0004074/5.807, allocations: 0.5731 MB / 1.911 GB, free: 270.6 MB / 0.7794 GB Notification: Performance of selectInitializationVariablesDAE (initialization): time 0.008736/5.816, allocations: 4.998 MB / 1.916 GB, free: 265.6 MB / 0.7794 GB Notification: Performance of collectPreVariables (initialization): time 0.006202/5.822, allocations: 297.7 kB / 1.916 GB, free: 265.4 MB / 0.7794 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/LumpedStraightPipe.mo:10:3-11:71:writable] Warning: The parameter PressureLoss_Steam.lambda has fixed = false and a binding equation PressureLoss_Steam.lambda = 0.03, which is probably redundant. Setting fixed = false usually means there is an additional initial equation to determine the parameter value. The binding was ignored by old Modelica tools, but this is not according to the Modelica specification. Please remove the parameter binding, or bind the parameter to another parameter with fixed = false and no binding. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicWaterHeater.mo:38:3-38:111:writable] Warning: The parameter WaterHeating.COP0l has fixed = false and a binding equation WaterHeating.COP0l = 1.23, which is probably redundant. Setting fixed = false usually means there is an additional initial equation to determine the parameter value. The binding was ignored by old Modelica tools, but this is not according to the Modelica specification. Please remove the parameter binding, or bind the parameter to another parameter with fixed = false and no binding. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/ControlValve.mo:6:3-7:43:writable] Warning: The parameter ControlValve_eau.Cvmax has fixed = false and a binding equation ControlValve_eau.Cvmax = 354.534, which is probably redundant. Setting fixed = false usually means there is an additional initial equation to determine the parameter value. The binding was ignored by old Modelica tools, but this is not according to the Modelica specification. Please remove the parameter binding, or bind the parameter to another parameter with fixed = false and no binding. Notification: Performance of collectInitialEqns (initialization): time 0.003027/5.825, allocations: 3.992 MB / 1.92 GB, free: 261.4 MB / 0.7794 GB Notification: Performance of collectInitialBindings (initialization): time 0.01051/5.836, allocations: 5.85 MB / 1.926 GB, free: 255.6 MB / 0.7794 GB Notification: Performance of simplifyInitialFunctions (initialization): time 0.01693/5.853, allocations: 3.688 MB / 1.93 GB, free: 251.9 MB / 0.7794 GB Notification: Performance of setup shared object (initialization): time 6.719e-05/5.853, allocations: 309.1 kB / 1.93 GB, free: 251.6 MB / 0.7794 GB Notification: Performance of preBalanceInitialSystem (initialization): time 0.02385/5.877, allocations: 11.9 MB / 1.942 GB, free: 239.6 MB / 0.7794 GB Notification: Performance of partitionIndependentBlocks (initialization): time 0.03111/5.908, allocations: 16.09 MB / 1.957 GB, free: 222 MB / 0.7794 GB Notification: It was not possible to check the given initialization system for consistency symbolically, because the relevant equations are part of an algebraic loop. This is not supported yet. Notification: Performance of analyzeInitialSystem (initialization): time 1.55/7.458, allocations: 251.5 MB / 2.203 GB, free: 205.1 MB / 0.7794 GB Notification: Performance of solveInitialSystemEqSystem (initialization): time 0.0001376/7.458, allocations: 36 kB / 2.203 GB, free: 205.1 MB / 0.7794 GB Notification: Performance of matching and sorting (n=2354) (initialization): time 0.3569/7.815, allocations: 40.98 MB / 2.243 GB, free: 350.5 MB / 0.7794 GB Notification: Performance of prepare postOptimizeDAE: time 0.000286/7.815, allocations: 107 kB / 2.243 GB, free: 350.5 MB / 0.7794 GB Notification: Performance of postOpt simplifyComplexFunction (initialization): time 0.0003211/7.816, allocations: 115.6 kB / 2.243 GB, free: 350.5 MB / 0.7794 GB Notification: Performance of postOpt tearingSystem (initialization): time 1.423/9.239, allocations: 421.6 MB / 2.655 GB, free: 345.6 MB / 0.7794 GB Notification: Performance of postOpt solveSimpleEquations (initialization): time 0.007607/9.247, allocations: 1.793 MB / 2.657 GB, free: 345.6 MB / 0.7794 GB Notification: Performance of postOpt calculateStrongComponentJacobians (initialization): time 0.1227/9.369, allocations: 43.77 MB / 2.699 GB, free: 337 MB / 0.7794 GB Notification: Performance of postOpt simplifyAllExpressions (initialization): time 0.02064/9.39, allocations: 0.8264 MB / 2.7 GB, free: 336.3 MB / 0.7794 GB Notification: Performance of postOpt collapseArrayExpressions (initialization): time 0.005193/9.395, allocations: 0.9374 MB / 2.701 GB, free: 335.5 MB / 0.7794 GB Warning: Assuming fixed start value for the following 1 variables: regulation_Niveau.pIsat1.Integrateur1.x0:DISCRETE(fixed = true protected = true ) type: Real Warning: The initial conditions are over specified. The following 3 initial equations are redundant, so they are removed from the initialization system: $DER.WaterHeating.pipe_3.Q[20] = 0.0 singularPressureLossPurge.T = $START.singularPressureLossPurge.T WaterHeating.WaterHeating.zl = $START.WaterHeating.WaterHeating.zl. Notification: Model statistics after passing the back-end for initialization: * Number of independent subsystems: 528 * Number of states: 0 () * Number of discrete variables: 83 ($PRE.regulation_Niveau.pIsat1.Integrateur1.x0,regulation_Niveau.pIsat1.Integrateur1.x0,$PRE.checkValve.touvert,$whenCondition2,$PRE.checkValve.tferme,$whenCondition1,sourceP.C.ftype,WaterHeating.WaterHeating.Cl.ftype,WaterHeating.volumeC.Cs.ftype,sourceP1.C.ftype,WaterHeating.C1.ftype,WaterHeating.volumeD1.Cs3.ftype,WaterHeating.volumeD1.Cs2.ftype,WaterHeating.volumeD1.Cs1.ftype,WaterHeating.volumeD.Cs2.ftype,WaterHeating.volumeD1.fluids[1],WaterHeating.volumeD.Cs3.ftype,WaterHeating.volumeD.Cs1.ftype,WaterHeating.volumeD.fluids[1],WaterHeating.volumeC.Ce2.ftype,WaterHeating.volumeC.fluids[1],WaterHeating.WaterHeating.fluids[1],Puit_condenseur1.fluid,ControlValve_eau.fluid,WaterHeating.pipe_3.fluid,WaterHeating.pipe_1.fluid,WaterHeating.pipe_2.fluid,Puit_condenseur2.fluid,singularPressureLossWaterIn.fluid,singularPressureLossWaterOut.fluid,singularPressureLossPurge.fluid,PressureLoss_Steam.fluid,checkValve.tferme,checkValve.touvert,checkValve.ouvert,$PRE.checkValve.ouvert,regulation_Niveau.echelon.yL.signal,regulation_Niveau.edge.yL.signal,regulation_Niveau.edge.uL.signal,$PRE.regulation_Niveau.edge.uL.signal,$whenCondition3,sourceP1.fluid1,WaterHeating.volumeD1.fluid1,WaterHeating.volumeD.fluid1,WaterHeating.volumeC.fluid1,sourceP.fluid1,WaterHeating.WaterHeating.Cv.diff_on_2,sourceP.C.diff_on_2,PressureLoss_Steam.C2.diff_on_1,singularPressureLossPurge.C2.diff_on_2,singularPressureLossPurge.C1.diff_on_2,WaterHeating.WaterHeating.Cl.diff_on_1,singularPressureLossPurge.C2.diff_on_1,ControlValve_eau.C2.diff_on_1,singularPressureLossWaterOut.C1.diff_on_2,WaterHeating.volumeC.Cs.diff_on_1,refQ.C2.diff_on_1,singularPressureLossWaterIn.C2.diff_on_1,WaterHeating.volumeD.Ce.diff_on_2,sourceP1.C.diff_on_2,WaterHeating.C1.diff_on_1,WaterHeating.volumeD1.Cs3.diff_on_1,WaterHeating.volumeD1.Cs2.diff_on_1,WaterHeating.volumeD1.Cs1.diff_on_1,WaterHeating.volumeD1.Ce.diff_on_2,WaterHeating.volumeD1.Cs2.diff_on_2,WaterHeating.volumeD1.Cs1.diff_on_2,WaterHeating.volumeD.Cs3.diff_on_1,WaterHeating.volumeD.Cs2.diff_on_1,WaterHeating.volumeD.Cs1.diff_on_1,WaterHeating.volumeD.Cs3.diff_on_2,WaterHeating.volumeC.Ce3.diff_on_2,WaterHeating.volumeC.Ce2.diff_on_2,WaterHeating.volumeC.Ce1.diff_on_2,WaterHeating.volumeC.Ce2.diff_on_1,WaterHeating.pipe_2.C1.diff_on_2,WaterHeating.pipe_2.C2.diff_on_1,WaterHeating.pipe_1.C1.diff_on_2,WaterHeating.pipe_1.C2.diff_on_1,WaterHeating.pipe_3.C1.diff_on_2,WaterHeating.pipe_3.C2.diff_on_1,WaterHeating.WaterHeating.Ce.diff_on_2,WaterHeating.WaterHeating.NbTubT) * Number of discrete states: 0 () * Number of clocked states: 0 () * Top-level inputs: 0 Notification: Strong component statistics for initialization (1012): * Single equations (assignments): 1005 * Array equations: 0 * Algorithm blocks: 2 * Record equations: 3 * When equations: 0 * If-equations: 0 * Equation systems (not torn): 0 * Torn equation systems: 2 * Mixed (continuous/discrete) equation systems: 0 Notification: Torn system details for strict tearing set: * Linear torn systems (#iteration vars, #inner vars, density): 0 systems * Non-linear torn systems (#iteration vars, #inner vars): 2 systems {(1,3), (140,1142)} Notification: Performance of prepare postOptimizeDAE: time 0.01212/9.408, allocations: 3.407 MB / 2.704 GB, free: 332.7 MB / 0.7794 GB Notification: Performance of postOpt lateInlineFunction (simulation): time 0.004014/9.412, allocations: 0.954 MB / 2.705 GB, free: 332.2 MB / 0.7794 GB Notification: Performance of postOpt wrapFunctionCalls (simulation): time 0.2204/9.632, allocations: 49.57 MB / 2.754 GB, free: 293.4 MB / 0.7794 GB Notification: Performance of postOpt inlineArrayEqn (simulation): time 0.1475/9.78, allocations: 42.45 MB / 2.795 GB, free: 255 MB / 0.7794 GB Notification: Performance of postOpt constantLinearSystem (simulation): time 0.0002403/9.78, allocations: 24 kB / 2.795 GB, free: 255 MB / 0.7794 GB Notification: Performance of postOpt simplifysemiLinear (simulation): time 0.000533/9.78, allocations: 79.69 kB / 2.795 GB, free: 254.9 MB / 0.7794 GB Warning: The model contains alias variables with redundant start and/or conflicting nominal values. It is recommended to resolve the conflicts, because otherwise the system could be hard to solve. To print the conflicting alias sets and the chosen candidates please use -d=aliasConflicts. Notification: Performance of postOpt removeSimpleEquations (simulation): time 0.4675/10.25, allocations: 67.92 MB / 2.862 GB, free: 342.4 MB / 0.7794 GB Notification: Performance of postOpt simplifyComplexFunction (simulation): time 0.0001966/10.25, allocations: 6.562 kB / 2.862 GB, free: 342.4 MB / 0.7794 GB Notification: Performance of postOpt solveSimpleEquations (simulation): time 0.01845/10.27, allocations: 2.945 MB / 2.864 GB, free: 342.4 MB / 0.7794 GB Notification: Performance of postOpt tearingSystem (simulation): time 0.106/10.37, allocations: 22.79 MB / 2.887 GB, free: 341.4 MB / 0.7794 GB Notification: Performance of postOpt inputDerivativesUsed (simulation): time 0.006541/10.38, allocations: 0.7195 MB / 2.887 GB, free: 341.4 MB / 0.7794 GB Notification: Performance of postOpt calculateStrongComponentJacobians (simulation): time 0.229/10.61, allocations: 153.9 MB / 3.038 GB, free: 217.4 MB / 0.7794 GB Notification: Performance of postOpt calculateStateSetsJacobians (simulation): time 6.262e-06/10.61, allocations: 8 kB / 3.038 GB, free: 217.4 MB / 0.7794 GB Notification: Performance of postOpt symbolicJacobian (simulation): time 0.1864/10.79, allocations: 58.97 MB / 3.095 GB, free: 158.6 MB / 0.7794 GB Notification: Performance of postOpt removeConstants (simulation): time 0.01286/10.81, allocations: 3.804 MB / 3.099 GB, free: 154.8 MB / 0.7794 GB Notification: Performance of postOpt simplifyTimeIndepFuncCalls (simulation): time 0.006366/10.81, allocations: 447.9 kB / 3.099 GB, free: 154.4 MB / 0.7794 GB Notification: Performance of postOpt simplifyAllExpressions (simulation): time 0.01403/10.83, allocations: 0.6009 MB / 3.1 GB, free: 153.8 MB / 0.7794 GB Notification: Performance of postOpt findZeroCrossings (simulation): time 0.007337/10.84, allocations: 1.364 MB / 3.101 GB, free: 152.5 MB / 0.7794 GB Notification: Performance of postOpt collapseArrayExpressions (simulation): time 0.004701/10.84, allocations: 0.6518 MB / 3.102 GB, free: 151.8 MB / 0.7794 GB Notification: Performance of sorting global known variables: time 0.005101/10.85, allocations: 3.117 MB / 3.105 GB, free: 148.7 MB / 0.7794 GB Notification: Performance of sort global known variables: time 2.2e-07/10.85, allocations: 0 / 3.105 GB, free: 148.7 MB / 0.7794 GB Notification: Performance of remove unused functions: time 0.03215/10.88, allocations: 6.541 MB / 3.111 GB, free: 142.5 MB / 0.7794 GB Notification: Model statistics after passing the back-end for simulation: * Number of independent subsystems: 18 * Number of states: 175 (WaterHeating.WaterHeating.P,WaterHeating.WaterHeating.hl,WaterHeating.WaterHeating.hv,WaterHeating.WaterHeating.Vv,WaterHeating.WaterHeating.Tp,WaterHeating.pipe_3.P[2],WaterHeating.pipe_3.P[3],WaterHeating.pipe_3.P[4],WaterHeating.pipe_3.P[5],WaterHeating.pipe_3.P[6],WaterHeating.pipe_3.P[7],WaterHeating.pipe_3.P[8],WaterHeating.pipe_3.P[9],WaterHeating.pipe_3.P[10],WaterHeating.pipe_3.P[11],WaterHeating.pipe_3.P[12],WaterHeating.pipe_3.P[13],WaterHeating.pipe_3.P[14],WaterHeating.pipe_3.P[15],WaterHeating.pipe_3.P[16],WaterHeating.pipe_3.P[17],WaterHeating.pipe_3.P[18],WaterHeating.pipe_3.P[19],WaterHeating.pipe_3.P[20],WaterHeating.pipe_3.P[21],WaterHeating.pipe_3.Q[1],WaterHeating.pipe_3.Q[2],WaterHeating.pipe_3.Q[3],WaterHeating.pipe_3.Q[4],WaterHeating.pipe_3.Q[5],WaterHeating.pipe_3.Q[6],WaterHeating.pipe_3.Q[7],WaterHeating.pipe_3.Q[8],WaterHeating.pipe_3.Q[9],WaterHeating.pipe_3.Q[10],WaterHeating.pipe_3.Q[11],WaterHeating.pipe_3.Q[12],WaterHeating.pipe_3.Q[13],WaterHeating.pipe_3.Q[14],WaterHeating.pipe_3.Q[15],WaterHeating.pipe_3.Q[16],WaterHeating.pipe_3.Q[17],WaterHeating.pipe_3.Q[18],WaterHeating.pipe_3.Q[19],WaterHeating.pipe_3.Q[20],WaterHeating.pipe_3.Q[21],WaterHeating.pipe_3.h[2],WaterHeating.pipe_3.h[3],WaterHeating.pipe_3.h[4],WaterHeating.pipe_3.h[5],WaterHeating.pipe_3.h[6],WaterHeating.pipe_3.h[7],WaterHeating.pipe_3.h[8],WaterHeating.pipe_3.h[9],WaterHeating.pipe_3.h[10],WaterHeating.pipe_3.h[11],WaterHeating.pipe_3.h[12],WaterHeating.pipe_3.h[13],WaterHeating.pipe_3.h[14],WaterHeating.pipe_3.h[15],WaterHeating.pipe_3.h[16],WaterHeating.pipe_3.h[17],WaterHeating.pipe_3.h[18],WaterHeating.pipe_3.h[19],WaterHeating.pipe_3.h[20],WaterHeating.pipe_3.h[21],WaterHeating.Wall_3.Tp[1],WaterHeating.Wall_3.Tp[2],WaterHeating.Wall_3.Tp[3],WaterHeating.Wall_3.Tp[4],WaterHeating.Wall_3.Tp[5],WaterHeating.Wall_3.Tp[6],WaterHeating.Wall_3.Tp[7],WaterHeating.Wall_3.Tp[8],WaterHeating.Wall_3.Tp[9],WaterHeating.Wall_3.Tp[10],WaterHeating.Wall_3.Tp[11],WaterHeating.Wall_3.Tp[12],WaterHeating.Wall_3.Tp[13],WaterHeating.Wall_3.Tp[14],WaterHeating.Wall_3.Tp[15],WaterHeating.Wall_3.Tp[16],WaterHeating.Wall_3.Tp[17],WaterHeating.Wall_3.Tp[18],WaterHeating.Wall_3.Tp[19],WaterHeating.Wall_3.Tp[20],WaterHeating.pipe_1.P[2],WaterHeating.pipe_1.P[3],WaterHeating.pipe_1.P[4],WaterHeating.pipe_1.P[5],WaterHeating.pipe_1.P[6],WaterHeating.pipe_1.P[7],WaterHeating.pipe_1.P[8],WaterHeating.pipe_1.P[9],WaterHeating.pipe_1.P[10],WaterHeating.pipe_1.P[11],WaterHeating.pipe_1.Q[1],WaterHeating.pipe_1.Q[2],WaterHeating.pipe_1.Q[3],WaterHeating.pipe_1.Q[4],WaterHeating.pipe_1.Q[5],WaterHeating.pipe_1.Q[6],WaterHeating.pipe_1.Q[7],WaterHeating.pipe_1.Q[8],WaterHeating.pipe_1.Q[9],WaterHeating.pipe_1.Q[10],WaterHeating.pipe_1.Q[11],WaterHeating.pipe_1.h[2],WaterHeating.pipe_1.h[3],WaterHeating.pipe_1.h[4],WaterHeating.pipe_1.h[5],WaterHeating.pipe_1.h[6],WaterHeating.pipe_1.h[7],WaterHeating.pipe_1.h[8],WaterHeating.pipe_1.h[9],WaterHeating.pipe_1.h[10],WaterHeating.pipe_1.h[11],WaterHeating.Wall_1.Tp[1],WaterHeating.Wall_1.Tp[2],WaterHeating.Wall_1.Tp[3],WaterHeating.Wall_1.Tp[4],WaterHeating.Wall_1.Tp[5],WaterHeating.Wall_1.Tp[6],WaterHeating.Wall_1.Tp[7],WaterHeating.Wall_1.Tp[8],WaterHeating.Wall_1.Tp[9],WaterHeating.Wall_1.Tp[10],WaterHeating.pipe_2.P[2],WaterHeating.pipe_2.P[3],WaterHeating.pipe_2.P[4],WaterHeating.pipe_2.P[5],WaterHeating.pipe_2.P[6],WaterHeating.pipe_2.P[7],WaterHeating.pipe_2.P[8],WaterHeating.pipe_2.P[9],WaterHeating.pipe_2.P[10],WaterHeating.pipe_2.P[11],WaterHeating.pipe_2.Q[1],WaterHeating.pipe_2.Q[2],WaterHeating.pipe_2.Q[3],WaterHeating.pipe_2.Q[4],WaterHeating.pipe_2.Q[5],WaterHeating.pipe_2.Q[6],WaterHeating.pipe_2.Q[7],WaterHeating.pipe_2.Q[8],WaterHeating.pipe_2.Q[9],WaterHeating.pipe_2.Q[10],WaterHeating.pipe_2.Q[11],WaterHeating.pipe_2.h[2],WaterHeating.pipe_2.h[3],WaterHeating.pipe_2.h[4],WaterHeating.pipe_2.h[5],WaterHeating.pipe_2.h[6],WaterHeating.pipe_2.h[7],WaterHeating.pipe_2.h[8],WaterHeating.pipe_2.h[9],WaterHeating.pipe_2.h[10],WaterHeating.pipe_2.h[11],WaterHeating.Wall_2.Tp[1],WaterHeating.Wall_2.Tp[2],WaterHeating.Wall_2.Tp[3],WaterHeating.Wall_2.Tp[4],WaterHeating.Wall_2.Tp[5],WaterHeating.Wall_2.Tp[6],WaterHeating.Wall_2.Tp[7],WaterHeating.Wall_2.Tp[8],WaterHeating.Wall_2.Tp[9],WaterHeating.Wall_2.Tp[10],WaterHeating.volumeC.P,WaterHeating.volumeC.h,WaterHeating.volumeD.h,WaterHeating.volumeD1.P,WaterHeating.volumeD1.h,regulation_Niveau.pIsat1.Integrateur1.x,regulation_Niveau.pT1_1.x) * Number of discrete variables: 11 ($whenCondition3,$whenCondition2,$whenCondition1,regulation_Niveau.pIsat1.Integrateur1.x0,regulation_Niveau.edge.uL.signal,regulation_Niveau.edge.yL.signal,regulation_Niveau.echelon.yL.signal,checkValve.ouvert,checkValve.touvert,checkValve.tferme,singularPressureLossPurge.C1.diff_on_2) * Number of discrete states: 5 (checkValve.touvert,checkValve.tferme,regulation_Niveau.echelon.yL.signal,regulation_Niveau.edge.yL.signal,regulation_Niveau.edge.uL.signal) * Number of clocked states: 0 () * Top-level inputs: 0 Notification: Strong component statistics for simulation (1393): * Single equations (assignments): 1257 * Array equations: 0 * Algorithm blocks: 2 * Record equations: 5 * When equations: 2 * If-equations: 0 * Equation systems (not torn): 42 * Torn equation systems: 85 * Mixed (continuous/discrete) equation systems: 0 Notification: Equation system details (not torn): * Constant Jacobian (size): 0 systems * Linear Jacobian (size,density): 42 systems {(2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%)} * Non-linear Jacobian (size): 0 systems * Without analytic Jacobian (size): 0 systems Notification: Torn system details for strict tearing set: * Linear torn systems (#iteration vars, #inner vars, density): 41 systems {(4,1,62.5%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%)} * Non-linear torn systems (#iteration vars, #inner vars): 44 systems {(1,3), (1,3), (1,3), (1,3), (1,3), (1,3), (1,3), (1,3), (2,6), (1,4), (1,4), (1,4), (1,4), (1,4), (1,4), (1,4), (1,4), (1,4), (1,4), (1,4), (1,4), (1,4), (1,4), (1,4), (1,4), (1,4), (1,4), (1,4), (1,4), (1,4), (1,4), (1,4), (1,4), (1,4), (1,4), (1,4), (1,4), (1,4), (1,4), (1,3), (1,3), (3,10), (1,4), (2,7)} Notification: Performance of Backend phase and start with SimCode phase: time 0.4358/11.31, allocations: 63.13 MB / 3.173 GB, free: 326.4 MB / 0.7794 GB Notification: Performance of simCode: created initialization part: time 0.343/11.66, allocations: 151.8 MB / 3.321 GB, free: 213.4 MB / 0.7794 GB Notification: Performance of simCode: created event and clocks part: time 1.311e-05/11.66, allocations: 0 / 3.321 GB, free: 213.4 MB / 0.7794 GB Notification: Performance of simCode: created simulation system equations: time 0.05014/11.71, allocations: 27.14 MB / 3.348 GB, free: 187.3 MB / 0.7794 GB Notification: Performance of simCode: created of all other equations (e.g. parameter, nominal, assert, etc): time 0.01916/11.73, allocations: 2.207 MB / 3.35 GB, free: 185.7 MB / 0.7794 GB Notification: Performance of simCode: created linear, non-linear and system jacobian parts: time 0.6817/12.41, allocations: 221.3 MB / 3.566 GB, free: 190.4 MB / 0.7794 GB Notification: Performance of simCode: some other stuff during SimCode phase: time 0.00931/12.42, allocations: 6.322 MB / 3.572 GB, free: 184.1 MB / 0.7794 GB Notification: Performance of simCode: alias equations: time 0.01971/12.44, allocations: 4.776 MB / 3.577 GB, free: 179.4 MB / 0.7794 GB Notification: Performance of simCode: all other stuff during SimCode phase: time 0.01533/12.45, allocations: 5.357 MB / 3.582 GB, free: 174.1 MB / 0.7794 GB Notification: Performance of SimCode: time 1.573e-06/12.45, allocations: 0 / 3.582 GB, free: 174.1 MB / 0.7794 GB Notification: Performance of buildModelFMU: Generate the FMI files: time 1.393/13.84, allocations: 0.5446 GB / 4.127 GB, free: 315.4 MB / 0.7794 GB Notification: Performance of buildModelFMU: Generate platform static: time 31.39/45.24, allocations: 4.656 kB / 4.127 GB, free: 315.4 MB / 0.7794 GB (rm -f ThermoSysPro_ThermoSysPro.Fluid.Examples.Book.SimpleExamples.HeatExchanger.DynamicWaterHeater.ZeroFlow.pipe ; mkfifo ThermoSysPro_ThermoSysPro.Fluid.Examples.Book.SimpleExamples.HeatExchanger.DynamicWaterHeater.ZeroFlow.pipe ; head -c 1048576 < ThermoSysPro_ThermoSysPro.Fluid.Examples.Book.SimpleExamples.HeatExchanger.DynamicWaterHeater.ZeroFlow.pipe >> ../files/ThermoSysPro_ThermoSysPro.Fluid.Examples.Book.SimpleExamples.HeatExchanger.DynamicWaterHeater.ZeroFlow.sim & /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --tempDir=temp_ThermoSysPro_ThermoSysPro_Fluid_Examples_Book_SimpleExamples_HeatExchanger_DynamicWaterHeater_ZeroFlow_fmu --startTime=0 --stopTime=3000 --timeout=50 --tolerance=1e-06 ThermoSysPro_ThermoSysPro_Fluid_Examples_Book_SimpleExamples_HeatExchanger_DynamicWaterHeater_ZeroFlow.fmu > ThermoSysPro_ThermoSysPro.Fluid.Examples.Book.SimpleExamples.HeatExchanger.DynamicWaterHeater.ZeroFlow.pipe 2>&1)