OMSimulator --tempDir=temp_EHPTexamples_main_EHPTexamples_EV_MBEV_fmu --startTime=0 --stopTime=1400 --timeout=50 --tolerance=0.0001 EHPTexamples_main_EHPTexamples_EV_MBEV.fmu LOG_STDOUT | info | ... loading "Cycle" from "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/EHPTexamples_main_EHPTexamples.EV.MBEV/temp_EHPTexamples_main_EHPTexamples_EV_MBEV_fmu/model-oi62u6qg/temp/0001_EHPTexamples_main_EHPTexamples_EV_MBEV/resources/home/hudson/saved_omc/libraries/.openmodelica/libraries/EHPTexamples main/Resources/NEDC.txt" LOG_STDOUT | info | ... loading "effTable" from "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/EHPTexamples_main_EHPTexamples.EV.MBEV/temp_EHPTexamples_main_EHPTexamples_EV_MBEV_fmu/model-oi62u6qg/temp/0001_EHPTexamples_main_EHPTexamples_EV_MBEV/resources/home/hudson/saved_omc/libraries/.openmodelica/libraries/EHPTexamples main/Resources/EVmaps.txt" info: maximum step size for 'model.root': 0.001000 info: Result file: model_res.mat (bufferSize=10) info: Variable model.root.EHPTexamples_main_EHPTexamples_EV_MBEV.driver.driveCyc.fileName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.EHPTexamples_main_EHPTexamples_EV_MBEV.driver.driveCyc.tableName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.EHPTexamples_main_EHPTexamples_EV_MBEV.eleDrive.effTableName will not be stored in the result file, because the signal type is not supported info: Variable model.root.EHPTexamples_main_EHPTexamples_EV_MBEV.eleDrive.toElePow.effTableName will not be stored in the result file, because the signal type is not supported info: Variable model.root.EHPTexamples_main_EHPTexamples_EV_MBEV.eleDrive.toElePow.mapsFileName will not be stored in the result file, because the signal type is not supported info: Variable model.root.EHPTexamples_main_EHPTexamples_EV_MBEV.eleDrive.toElePow.toEff.fileName will not be stored in the result file, because the signal type is not supported info: Variable model.root.EHPTexamples_main_EHPTexamples_EV_MBEV.eleDrive.toElePow.toEff.tableName will not be stored in the result file, because the signal type is not supported error: [operator()] Timeout occurred during simulation info: 0 warnings info: 1 errors error: [fmi2logger] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/EHPTexamples_main_EHPTexamples.EV.MBEV/temp_EHPTexamples_main_EHPTexamples_EV_MBEV_fmu/model-oi62u6qg/temp/0001_EHPTexamples_main_EHPTexamples_EV_MBEV (logStatusError): fmi2SetContinuousStates: Illegal model exchange call sequence. fmi2SetContinuousStates is not allowed in model_state_terminated state. error: [setContinuousStates] fmi2_setContinuousStates failed for FMU "model.root.EHPTexamples_main_EHPTexamples_EV_MBEV"