/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --tempDir=temp_Buildings_8_Buildings_Fluid_CHPs_Validation_ThermalFollowing_fmu --startTime=0 --stopTime=10000 --timeout=50 --tolerance=1e-06 Buildings_8_Buildings_Fluid_CHPs_Validation_ThermalFollowing.fmu LOG_STDOUT | info | ... loading "tab1" from "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_8_Buildings.Fluid.CHPs.Validation.ThermalFollowing/temp_Buildings_8_Buildings_Fluid_CHPs_Validation_ThermalFollowing_fmu/model-xgsd7mdb/temp/0001_Buildings_8_Buildings_Fluid_CHPs_Validation_ThermalFollowing/resources/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/Resources/Data/Fluid/CHPs/Validation/MicroCogeneration.mos" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/Controls/OBC/CDL/Utilities/Assert.mo:11:3-14:28:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((theFolNeg.opeMod.assWatMas.nand.y)) --> "Water flow rate is lower than the minimum!" info: maximum step size for 'model.root': 0.001000 info: Result file: model_res.mat (bufferSize=10) info: Parameter model.root.Buildings_8_Buildings_Fluid_CHPs_Validation_ThermalFollowing.avaSig.combiTimeTable.fileName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.Buildings_8_Buildings_Fluid_CHPs_Validation_ThermalFollowing.avaSig.combiTimeTable.tableName will not be stored in the result file, because the signal type is not supported info: Variable model.root.Buildings_8_Buildings_Fluid_CHPs_Validation_ThermalFollowing.theFol.assWatTem.assMes.message will not be stored in the result file, because the signal type is not supported info: Variable model.root.Buildings_8_Buildings_Fluid_CHPs_Validation_ThermalFollowing.theFol.fil.assPow.assMesDP.message will not be stored in the result file, because the signal type is not supported info: Variable model.root.Buildings_8_Buildings_Fluid_CHPs_Validation_ThermalFollowing.theFol.fil.assPow.assMesP.message will not be stored in the result file, because the signal type is not supported info: Variable model.root.Buildings_8_Buildings_Fluid_CHPs_Validation_ThermalFollowing.theFolNeg.assWatTem.assMes.message will not be stored in the result file, because the signal type is not supported info: Variable model.root.Buildings_8_Buildings_Fluid_CHPs_Validation_ThermalFollowing.theFolNeg.fil.assPow.assMesDP.message will not be stored in the result file, because the signal type is not supported info: Variable model.root.Buildings_8_Buildings_Fluid_CHPs_Validation_ThermalFollowing.theFolNeg.fil.assPow.assMesP.message will not be stored in the result file, because the signal type is not supported info: Parameter model.root.Buildings_8_Buildings_Fluid_CHPs_Validation_ThermalFollowing.valDat.tableName will not be stored in the result file, because the signal type is not supported error: [operator()] Timeout occurred during simulation info: 0 warnings info: 1 errors error: [fmi2logger] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_8_Buildings.Fluid.CHPs.Validation.ThermalFollowing/temp_Buildings_8_Buildings_Fluid_CHPs_Validation_ThermalFollowing_fmu/model-xgsd7mdb/temp/0001_Buildings_8_Buildings_Fluid_CHPs_Validation_ThermalFollowing (logStatusError): fmi2SetTime: Illegal model exchange call sequence. fmi2SetTime is not allowed in model_state_terminated state. error: [doStep] fmi2_setTime failed for FMU "model.root.Buildings_8_Buildings_Fluid_CHPs_Validation_ThermalFollowing"