/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --tempDir=temp_Buildings_11_Buildings_ThermalZones_EnergyPlus_9_6_0_BaseClasses_Validation_FMUZoneAdapterZones1_fmu --startTime=0 --stopTime=3600 --timeout=400 --tolerance=1e-06 Buildings_11_Buildings_ThermalZones_EnergyPlus_9_6_0_BaseClasses_Validation_FMUZoneAdapterZones1.fmu LOG_STDOUT | info | 0.000 FMUZoneAdapterZones1.building: Using pre-compiled FMU /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_11_Buildings.ThermalZones.EnergyPlus_9_6_0.BaseClasses.Validation.FMUZoneAdapterZones1/temp_Buildings_11_Buildings_ThermalZones_EnergyPlus_9_6_0_BaseClasses_Validation_FMUZoneAdapterZones1_fmu/model-hhuyjgxy/temp/0001_Buildings_11_Buildings_ThermalZones_EnergyPlus_9_6_0_BaseClasses_Validation_FMUZoneAdapterZones1/resources/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.0-maint.11.x/Resources/src/ThermalZones/EnergyPlus_9_6_0/FMUs/Zones1.fmu LOG_STDOUT | info | 0.000 FMUZoneAdapterZones1.building: Warning: Variable Core_ZN_mSenFac does not specify units in /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_11_Buildings.ThermalZones.EnergyPlus_9_6_0.BaseClasses.Validation.FMUZoneAdapterZones1/spawn-FMUZoneAdapterZones1/EnergyPlus.fmu. It will not be converted to SI units. LOG_STDOUT | info | 0.000 FMUZoneAdapterZones1.building: Warning from EnergyPlus: "*** Test warning written by Zones1.core.&##10;" info: maximum step size for 'model.root': 0.001000 info: Result file: model_res.mat (bufferSize=10) info: Variable model.root.Buildings_11_Buildings_ThermalZones_EnergyPlus_9_6_0_BaseClasses_Validation_FMUZoneAdapterZones1.fmuZonCor.epwName will not be stored in the result file, because the signal type is not supported info: Variable model.root.Buildings_11_Buildings_ThermalZones_EnergyPlus_9_6_0_BaseClasses_Validation_FMUZoneAdapterZones1.fmuZonCor.fmuName will not be stored in the result file, because the signal type is not supported info: Variable model.root.Buildings_11_Buildings_ThermalZones_EnergyPlus_9_6_0_BaseClasses_Validation_FMUZoneAdapterZones1.fmuZonCor.idfName will not be stored in the result file, because the signal type is not supported info: Variable model.root.Buildings_11_Buildings_ThermalZones_EnergyPlus_9_6_0_BaseClasses_Validation_FMUZoneAdapterZones1.fmuZonCor.zoneName will not be stored in the result file, because the signal type is not supported LOG_STDOUT | info | 60.001 FMUZoneAdapterZones1.building: Error from EnergyPlus: Current time 6.0001000000000005E+01 is after next time event 6.0000000000000000E+01. Consider to change option 2.2204460492503131E-14. LOG_ASSERT | debug | 60.001 FMUZoneAdapterZones1.fmuZonCor: Failed to enter event mode in SpawnUtil.c, returned status is Error. error: [fmi2logger] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_11_Buildings.ThermalZones.EnergyPlus_9_6_0.BaseClasses.Validation.FMUZoneAdapterZones1/temp_Buildings_11_Buildings_ThermalZones_EnergyPlus_9_6_0_BaseClasses_Validation_FMUZoneAdapterZones1_fmu/model-hhuyjgxy/temp/0001_Buildings_11_Buildings_ThermalZones_EnergyPlus_9_6_0_BaseClasses_Validation_FMUZoneAdapterZones1 (logFmi2Call): internalEventUpdate: terminated by an assertion. error: [doEventIteration] fmi2_import_new_discrete_states failed for FMU "model.root.Buildings_11_Buildings_ThermalZones_EnergyPlus_9_6_0_BaseClasses_Validation_FMUZoneAdapterZones1" error: [operator()] Timeout occurred during simulation info: 0 warnings info: 3 errors info: Final Statistics for 'model.root': NumSteps = 2793928 NumRhsEvals = 2793929 NumLinSolvSetups = 139698 NumNonlinSolvIters = 2793928 NumNonlinSolvConvFails = 0 NumErrTestFails = 0 [CVODE ERROR] CVode cvode_mem = NULL illegal. error: [doStep] SUNDIALS_ERROR: CVode() failed with flag = -21