/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator -r=Buildings_11_Buildings.Fluid.DXSystems.Heating.AirSource.Validation.SingleSpeed_TimedResistiveDefrost_res.mat --tempDir=temp_Buildings_11_Buildings_Fluid_DXSystems_Heating_AirSource_Validation_SingleSpeed_TimedResistiveDefrost_fmu --startTime=0 --stopTime=172800 --timeout=400 --tolerance=1e-06 Buildings_11_Buildings_Fluid_DXSystems_Heating_AirSource_Validation_SingleSpeed_TimedResistiveDefrost.fmu LOG_STDOUT | info | ... loading "EnergyPlus" from "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_11_Buildings.Fluid.DXSystems.Heating.AirSource.Validation.SingleSpeed_TimedResistiveDefrost/temp_Buildings_11_Buildings_Fluid_DXSystems_Heating_AirSource_Validation_SingleSpeed_TimedResistiveDefrost_fmu/model-hjq5pl8s/temp/0001_Buildings_11_Buildings_Fluid_DXSystems_Heating_AirSource_Validation_SingleSpeed_TimedResistiveDefrost/resources/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.0-maint.11.x/Resources/Data/Fluid/DXSystems/Heating/AirSource/Validation/SingleSpeedHeating_TimedResistiveDefrost/DXCoilSystemAuto.dat" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.0-maint.11.x/Fluid/DXSystems/Cooling/AirSource/Data/Generic/BaseClasses/NominalValues.mo:6:3-8:51:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((sinSpeDX.dxCoi.datCoi.sta[1].nomVal.Q_flow_nominal <= 0.0)) --> "Variable violating max constraint: sinSpeDX.dxCoi.datCoi.sta[1].nomVal.Q_flow_nominal <= 0.0, has value: 15000" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.0-maint.11.x/Fluid/DXSystems/Cooling/AirSource/Data/Generic/BaseClasses/NominalValues.mo:6:3-8:51:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((sinSpeDX.dxCoi.coiCap.sta[1].nomVal.Q_flow_nominal <= 0.0)) --> "Variable violating max constraint: sinSpeDX.dxCoi.coiCap.sta[1].nomVal.Q_flow_nominal <= 0.0, has value: 15000" warning: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_11_Buildings.Fluid.DXSystems.Heating.AirSource.Validation.SingleSpeed_TimedResistiveDefrost/temp_Buildings_11_Buildings_Fluid_DXSystems_Heating_AirSource_Validation_SingleSpeed_TimedResistiveDefrost_fmu/model-hjq5pl8s/temp/0001_Buildings_11_Buildings_Fluid_DXSystems_Heating_AirSource_Validation_SingleSpeed_TimedResistiveDefrost (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.0-maint.11.x/Fluid/DXSystems/Cooling/BaseClasses/Functions/warnIfPerformanceOutOfBounds.mo:18: *** Warning: DX coil performance curves at nominal conditions are outside of bounds. Capacity as a function of temperature is outside of bounds 0.9 to 1.1. The value of the curve fit is 11.9899 Check the coefficients of the function sta[1].perCur.capFunT. info: maximum step size for 'model.root': 0.001000 info: Result file: Buildings_11_Buildings.Fluid.DXSystems.Heating.AirSource.Validation.SingleSpeed_TimedResistiveDefrost_res.mat (bufferSize=1) info: Variable model.root.Buildings_11_Buildings_Fluid_DXSystems_Heating_AirSource_Validation_SingleSpeed_TimedResistiveDefrost.datRea.fileName will not be stored in the result file, because the signal type is not supported info: Variable model.root.Buildings_11_Buildings_Fluid_DXSystems_Heating_AirSource_Validation_SingleSpeed_TimedResistiveDefrost.datRea.tableName will not be stored in the result file, because the signal type is not supported error: [operator()] Timeout occurred during simulation info: 1 warnings info: 1 errors info: Final Statistics for 'model.root': NumSteps = 1131703 NumRhsEvals = 1131704 NumLinSolvSetups = 56587 NumNonlinSolvIters = 1131703 NumNonlinSolvConvFails = 0 NumErrTestFails = 0 [CVODE ERROR] CVode cvode_mem = NULL illegal. error: [doStep] SUNDIALS_ERROR: CVode() failed with flag = -21