/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator -r=Buildings_11_Buildings.Fluid.DXSystems.Cooling.WaterSource.Validation.VariableSpeedEnergyPlusPartLoad_res.mat --tempDir=temp_Buildings_11_Buildings_Fluid_DXSystems_Cooling_WaterSource_Validation_VariableSpeedEnergyPlusPartLoad_fmu --startTime=0 --stopTime=86400 --timeout=400 --tolerance=1e-06 Buildings_11_Buildings_Fluid_DXSystems_Cooling_WaterSource_Validation_VariableSpeedEnergyPlusPartLoad.fmu LOG_NLS | error | residualFunc1198: Iteration variable xloc[1] is nan. LOG_ASSERT | debug | residualFunc1198 failed at time=0. | | | | For more information please use -lv LOG_NLS. LOG_STDOUT | warning | While solving non-linear system an assertion failed during initialization. | | | | | The non-linear solver tries to solve the problem that could take some time. | | | | | It could help to provide better start-values for the iteration variables. | | | | | For more information simulate with -lv LOG_NLS_V LOG_NLS | error | residualFunc1198: Iteration variable xloc[6] is nan. LOG_ASSERT | debug | residualFunc1198 failed at time=0. | | | | For more information please use -lv LOG_NLS. LOG_NLS | error | residualFunc1198: Iteration variable xloc[1] is nan. LOG_ASSERT | debug | residualFunc1198 failed at time=0. | | | | For more information please use -lv LOG_NLS. LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.0-maint.11.x/Fluid/DXSystems/Cooling/BaseClasses/Evaporation.mo:185:3-194:27:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((varSpeDX.eva.watVapEva.nomVal.gamma <= varSpeDX.eva.watVapEva.gammaMax)) --> "*** Warning: In DX coil model, gamma is too large for these coil conditions. | | | | Instead of gamma = 1.5, a value of 0.346977, which | | | | corresponds to a mass transfer effectiveness of 0.8, will be used. | | | | Coil nominal performance data are: | | | | nomVal.m_flow_nominal = 0.462462 | | | | dX_nominal = XEvaOut_nominal-XEvaWetBulOut_nominal = 0.00571197 - 0.00634552 = -0.000633544 | | | | QLat_flow_nominal = -1689.5 | | | | " info: maximum step size for 'model.root': 0.001000 info: Result file: Buildings_11_Buildings.Fluid.DXSystems.Cooling.WaterSource.Validation.VariableSpeedEnergyPlusPartLoad_res.mat (bufferSize=1) error: [operator()] Timeout occurred during simulation info: 0 warnings info: 1 errors info: Final Statistics for 'model.root': NumSteps = 91293 NumRhsEvals = 91294 NumLinSolvSetups = 4566 NumNonlinSolvIters = 91293 NumNonlinSolvConvFails = 0 NumErrTestFails = 0 [CVODE ERROR] CVode cvode_mem = NULL illegal. error: [doStep] SUNDIALS_ERROR: CVode() failed with flag = -21