/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator -r=Buildings_10_Buildings.Fluid.Movers.Preconfigured.Validation.ControlledFlowMachinePreconfigured_res.mat --tempDir=temp_Buildings_10_Buildings_Fluid_Movers_Preconfigured_Validation_ControlledFlowMachinePreconfigured_fmu --startTime=0 --stopTime=600 --timeout=50 --tolerance=1e-06 Buildings_10_Buildings_Fluid_Movers_Preconfigured_Validation_ControlledFlowMachinePreconfigured.fmu LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.1-maint.10.0.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:99:3-99:89:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((fan1.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= fan1.etaHyd, has value: -5.22765e-26" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.1-maint.10.0.x/Fluid/Movers/BaseClasses/PowerInterface.mo:46:3-47:27:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((fan1.heaDis.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= fan1.heaDis.etaHyd, has value: -9.75828e-22" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.1-maint.10.0.x/Fluid/Movers/BaseClasses/FlowMachineInterface.mo:311:3-315:28:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((fan3.eff.yMot >= 0.0)) --> "Variable violating min constraint: 0.0 <= fan3.eff.yMot, has value: -2.01147e-25" info: maximum step size for 'model.root': 0.001000 info: Result file: Buildings_10_Buildings.Fluid.Movers.Preconfigured.Validation.ControlledFlowMachinePreconfigured_res.mat (bufferSize=1) error: [operator()] Timeout occurred during simulation info: 0 warnings info: 1 errors error: [fmi2logger] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_10_Buildings.Fluid.Movers.Preconfigured.Validation.ControlledFlowMachinePreconfigured/temp_Buildings_10_Buildings_Fluid_Movers_Preconfigured_Validation_ControlledFlowMachinePreconfigured_fmu/model-ws7k7yqv/temp/0001_Buildings_10_Buildings_Fluid_Movers_Preconfigured_Validation_ControlledFlowMachinePreconfigured (logStatusError): fmi2SetTime: Illegal model exchange call sequence. fmi2SetTime is not allowed in model_state_terminated state. error: [doStep] fmi2_setTime failed for FMU "model.root.Buildings_10_Buildings_Fluid_Movers_Preconfigured_Validation_ControlledFlowMachinePreconfigured"