/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator -r=Buildings_10_Buildings.Examples.Tutorial.SpaceCooling.System3_res.mat --tempDir=temp_Buildings_10_Buildings_Examples_Tutorial_SpaceCooling_System3_fmu --startTime=1.5552e+07 --stopTime=1.56384e+07 --timeout=50 --tolerance=1e-06 Buildings_10_Buildings_Examples_Tutorial_SpaceCooling_System3.fmu LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.1-maint.10.0.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:389:3-396:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((fan.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning in System3.fan: Mover is flow or pressure controlled and uses default pressure curve. | | | | This leads to an approximate power consumption. | | | | Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.1-maint.10.0.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:417:3-427:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((not (fan.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.Power_VolumeFlowRate or fan.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.EulerNumber))) --> "*** Warning in System3.fan: Mover has per.etaHydMet=.Power_VolumeFlowRate or per.etaHydMet=.EulerNumber. | | | | This requires per.pressure to be provided. | | | | Because it is not, the model overrides this setting by using per.etaHydMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.1-maint.10.0.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:429:3-439:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((fan.per.haveWMot_nominal or not (fan.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.Efficiency_MotorPartLoadRatio or fan.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.GenericCurve))) --> "*** Warning in System3.fan: Mover has per.etaMotMet=.Efficiency_MotorPartLoadRatio or per.etaMotMet=.GenericCurve. | | | | This requires per.WMot_nominal or per.pressure to be provided. Because neither is provided, | | | | the model overrides this setting and by using per.etaMotMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve." info: maximum step size for 'model.root': 0.001000 info: Result file: Buildings_10_Buildings.Examples.Tutorial.SpaceCooling.System3_res.mat (bufferSize=1) error: [operator()] Timeout occurred during simulation info: 0 warnings info: 1 errors error: [fmi2logger] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_10_Buildings.Examples.Tutorial.SpaceCooling.System3/temp_Buildings_10_Buildings_Examples_Tutorial_SpaceCooling_System3_fmu/model-615mct8t/temp/0001_Buildings_10_Buildings_Examples_Tutorial_SpaceCooling_System3 (logStatusError): fmi2SetTime: Illegal model exchange call sequence. fmi2SetTime is not allowed in model_state_terminated state. error: [doStep] fmi2_setTime failed for FMU "model.root.Buildings_10_Buildings_Examples_Tutorial_SpaceCooling_System3" error: [fmi2logger] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_10_Buildings.Examples.Tutorial.SpaceCooling.System3/temp_Buildings_10_Buildings_Examples_Tutorial_SpaceCooling_System3_fmu/model-615mct8t/temp/0001_Buildings_10_Buildings_Examples_Tutorial_SpaceCooling_System3 (logStatusError): fmi2SetContinuousStates: Illegal model exchange call sequence. fmi2SetContinuousStates is not allowed in model_state_error state. error: [setContinuousStates] fmi2_setContinuousStates failed for FMU "model.root.Buildings_10_Buildings_Examples_Tutorial_SpaceCooling_System3" error: [fmi2logger] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_10_Buildings.Examples.Tutorial.SpaceCooling.System3/temp_Buildings_10_Buildings_Examples_Tutorial_SpaceCooling_System3_fmu/model-615mct8t/temp/0001_Buildings_10_Buildings_Examples_Tutorial_SpaceCooling_System3 (logStatusError): fmi2SetContinuousStates: Illegal model exchange call sequence. fmi2SetContinuousStates is not allowed in model_state_error state. error: [setContinuousStates] fmi2_setContinuousStates failed for FMU "model.root.Buildings_10_Buildings_Examples_Tutorial_SpaceCooling_System3" error: [fmi2logger] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_10_Buildings.Examples.Tutorial.SpaceCooling.System3/temp_Buildings_10_Buildings_Examples_Tutorial_SpaceCooling_System3_fmu/model-615mct8t/temp/0001_Buildings_10_Buildings_Examples_Tutorial_SpaceCooling_System3 (logStatusError): fmi2SetContinuousStates: Illegal model exchange call sequence. fmi2SetContinuousStates is not allowed in model_state_error state. error: [setContinuousStates] fmi2_setContinuousStates failed for FMU "model.root.Buildings_10_Buildings_Examples_Tutorial_SpaceCooling_System3" error: [fmi2logger] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_10_Buildings.Examples.Tutorial.SpaceCooling.System3/temp_Buildings_10_Buildings_Examples_Tutorial_SpaceCooling_System3_fmu/model-615mct8t/temp/0001_Buildings_10_Buildings_Examples_Tutorial_SpaceCooling_System3 (logStatusError): fmi2SetContinuousStates: Illegal model exchange call sequence. fmi2SetContinuousStates is not allowed in model_state_error state. error: [setContinuousStates] fmi2_setContinuousStates failed for FMU "model.root.Buildings_10_Buildings_Examples_Tutorial_SpaceCooling_System3" error: [fmi2logger] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_10_Buildings.Examples.Tutorial.SpaceCooling.System3/temp_Buildings_10_Buildings_Examples_Tutorial_SpaceCooling_System3_fmu/model-615mct8t/temp/0001_Buildings_10_Buildings_Examples_Tutorial_SpaceCooling_System3 (logStatusError): fmi2SetContinuousStates: Illegal model exchange call sequence. fmi2SetContinuousStates is not allowed in model_state_error state. error: [setContinuousStates] fmi2_setContinuousStates failed for FMU "model.root.Buildings_10_Buildings_Examples_Tutorial_SpaceCooling_System3" error: [fmi2logger] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_10_Buildings.Examples.Tutorial.SpaceCooling.System3/temp_Buildings_10_Buildings_Examples_Tutorial_SpaceCooling_System3_fmu/model-615mct8t/temp/0001_Buildings_10_Buildings_Examples_Tutorial_SpaceCooling_System3 (logStatusError): fmi2SetContinuousStates: Illegal model exchange call sequence. fmi2SetContinuousStates is not allowed in model_state_error state. error: [setContinuousStates] fmi2_setContinuousStates failed for FMU "model.root.Buildings_10_Buildings_Examples_Tutorial_SpaceCooling_System3" error: [fmi2logger] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_10_Buildings.Examples.Tutorial.SpaceCooling.System3/temp_Buildings_10_Buildings_Examples_Tutorial_SpaceCooling_System3_fmu/model-615mct8t/temp/0001_Buildings_10_Buildings_Examples_Tutorial_SpaceCooling_System3 (logStatusError): fmi2SetContinuousStates: Illegal model exchange call sequence. fmi2SetContinuousStates is not allowed in model_state_error state. error: [setContinuousStates] fmi2_setContinuousStates failed for FMU "model.root.Buildings_10_Buildings_Examples_Tutorial_SpaceCooling_System3" error: [fmi2logger] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_10_Buildings.Examples.Tutorial.SpaceCooling.System3/temp_Buildings_10_Buildings_Examples_Tutorial_SpaceCooling_System3_fmu/model-615mct8t/temp/0001_Buildings_10_Buildings_Examples_Tutorial_SpaceCooling_System3 (logStatusError): fmi2SetContinuousStates: Illegal model exchange call sequence. fmi2SetContinuousStates is not allowed in model_state_error state. error: [setContinuousStates] fmi2_setContinuousStates failed for FMU "model.root.Buildings_10_Buildings_Examples_Tutorial_SpaceCooling_System3" error: [fmi2logger] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_10_Buildings.Examples.Tutorial.SpaceCooling.System3/temp_Buildings_10_Buildings_Examples_Tutorial_SpaceCooling_System3_fmu/model-615mct8t/temp/0001_Buildings_10_Buildings_Examples_Tutorial_SpaceCooling_System3 (logStatusError): fmi2SetContinuousStates: Illegal model exchange call sequence. fmi2SetContinuousStates is not allowed in model_state_error state. error: [setContinuousStates] fmi2_setContinuousStates failed for FMU "model.root.Buildings_10_Buildings_Examples_Tutorial_SpaceCooling_System3" error: [fmi2logger] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_10_Buildings.Examples.Tutorial.SpaceCooling.System3/temp_Buildings_10_Buildings_Examples_Tutorial_SpaceCooling_System3_fmu/model-615mct8t/temp/0001_Buildings_10_Buildings_Examples_Tutorial_SpaceCooling_System3 (logStatusError): fmi2SetContinuousStates: Illegal model exchange call sequence. fmi2SetContinuousStates is not allowed in model_state_error state. error: [setContinuousStates] fmi2_setContinuousStates failed for FMU "model.root.Buildings_10_Buildings_Examples_Tutorial_SpaceCooling_System3" error: [fmi2logger] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_10_Buildings.Examples.Tutorial.SpaceCooling.System3/temp_Buildings_10_Buildings_Examples_Tutorial_SpaceCooling_System3_fmu/model-615mct8t/temp/0001_Buildings_10_Buildings_Examples_Tutorial_SpaceCooling_System3 (logStatusError): fmi2SetContinuousStates: Illegal model exchange call sequence. fmi2SetContinuousStates is not allowed in model_state_error state. error: [setContinuousStates] fmi2_setContinuousStates failed for FMU "model.root.Buildings_10_Buildings_Examples_Tutorial_SpaceCooling_System3" error: [fmi2logger] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_10_Buildings.Examples.Tutorial.SpaceCooling.System3/temp_Buildings_10_Buildings_Examples_Tutorial_SpaceCooling_System3_fmu/model-615mct8t/temp/0001_Buildings_10_Buildings_Examples_Tutorial_SpaceCooling_System3 (logStatusError): fmi2SetContinuousStates: Illegal model exchange call sequence. fmi2SetContinuousStates is not allowed in model_state_error state. error: [setContinuousStates] fmi2_setContinuousStates failed for FMU "model.root.Buildings_10_Buildings_Examples_Tutorial_SpaceCooling_System3" error: [fmi2logger] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_10_Buildings.Examples.Tutorial.SpaceCooling.System3/temp_Buildings_10_Buildings_Examples_Tutorial_SpaceCooling_System3_fmu/model-615mct8t/temp/0001_Buildings_10_Buildings_Examples_Tutorial_SpaceCooling_System3 (logStatusError): fmi2SetContinuousStates: Illegal model exchange call sequence. fmi2SetContinuousStates is not allowed in model_state_error state. error: [setContinuousStates] fmi2_setContinuousStates failed for FMU "model.root.Buildings_10_Buildings_Examples_Tutorial_SpaceCooling_System3" error: [fmi2logger] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_10_Buildings.Examples.Tutorial.SpaceCooling.System3/temp_Buildings_10_Buildings_Examples_Tutorial_SpaceCooling_System3_fmu/model-615mct8t/temp/0001_Buildings_10_Buildings_Examples_Tutorial_SpaceCooling_System3 (logStatusError): fmi2SetContinuousStates: Illegal model exchange call sequence. fmi2SetContinuousStates is not allowed in model_state_error state. error: [setContinuousStates] fmi2_setContinuousStates failed for FMU "model.root.Buildings_10_Buildings_Examples_Tutorial_SpaceCooling_System3" error: [fmi2logger] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_10_Buildings.Examples.Tutorial.SpaceCooling.System3/temp_Buildings_10_Buildings_Examples_Tutorial_SpaceCooling_System3_fmu/model-615mct8t/temp/0001_Buildings_10_Buildings_Examples_Tutorial_SpaceCooling_System3 (logStatusError): fmi2SetContinuousStates: Illegal model exchange call sequence. fmi2SetContinuousStates is not allowed in model_state_error state. error: [setContinuousStates] fmi2_setContinuousStates failed for FMU "model.root.Buildings_10_Buildings_Examples_Tutorial_SpaceCooling_System3" error: [fmi2logger] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_10_Buildings.Examples.Tutorial.SpaceCooling.System3/temp_Buildings_10_Buildings_Examples_Tutorial_SpaceCooling_System3_fmu/model-615mct8t/temp/0001_Buildings_10_Buildings_Examples_Tutorial_SpaceCooling_System3 (logStatusError): fmi2SetContinuousStates: Illegal model exchange call sequence. fmi2SetContinuousStates is not allowed in model_state_error state. error: [setContinuousStates] fmi2_setContinuousStates failed for FMU "model.root.Buildings_10_Buildings_Examples_Tutorial_SpaceCooling_System3" [CVODE ERROR] CVode At t = 1.55525e+07 repeated recoverable right-hand side function errors. error: [doStep] SUNDIALS_ERROR: CVode() failed with flag = -10 error: [fmi2logger] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_10_Buildings.Examples.Tutorial.SpaceCooling.System3/temp_Buildings_10_Buildings_Examples_Tutorial_SpaceCooling_System3_fmu/model-615mct8t/temp/0001_Buildings_10_Buildings_Examples_Tutorial_SpaceCooling_System3 (logStatusError): fmi2SetContinuousStates: Illegal model exchange call sequence. fmi2SetContinuousStates is not allowed in model_state_error state. error: [setContinuousStates] fmi2_setContinuousStates failed for FMU "model.root.Buildings_10_Buildings_Examples_Tutorial_SpaceCooling_System3" info: Final Statistics for 'model.root': NumSteps = 468490 NumRhsEvals = 468509 NumLinSolvSetups = 23427 NumNonlinSolvIters = 468492 NumNonlinSolvConvFails = 16 NumErrTestFails = 0