/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator -r=Buildings_10_Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.CoolingCoilHumidifyingHeating_ClosedLoop_res.mat --tempDir=temp_Buildings_10_Buildings_Applications_DataCenters_ChillerCooled_Equipment_Validation_CoolingCoilHumidifyingHeating_ClosedLoop_fmu --startTime=0 --stopTime=2400 --timeout=50 --tolerance=1e-06 Buildings_10_Buildings_Applications_DataCenters_ChillerCooled_Equipment_Validation_CoolingCoilHumidifyingHeating_ClosedLoop.fmu LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.1-maint.10.0.x/Fluid/HeatExchangers/WetCoilEffectivenessNTU.mo:71:3-76:35:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((ahu.cooCoi.SHR >= 0.0 and ahu.cooCoi.SHR <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= ahu.cooCoi.SHR <= 1.0, has value: -4.66435e-17" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.1-maint.10.0.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:99:3-99:89:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((ahu.fan.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= ahu.fan.etaHyd, has value: -1.36173e-25" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.1-maint.10.0.x/Fluid/Movers/BaseClasses/PowerInterface.mo:46:3-47:27:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((ahu.fan.heaDis.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= ahu.fan.heaDis.etaHyd, has value: -8.35831e-21" info: maximum step size for 'model.root': 0.001000 info: Result file: Buildings_10_Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.CoolingCoilHumidifyingHeating_ClosedLoop_res.mat (bufferSize=1) info: Variable model.root.Buildings_10_Buildings_Applications_DataCenters_ChillerCooled_Equipment_Validation_CoolingCoilHumidifyingHeating_ClosedLoop.masFra.substanceName will not be stored in the result file, because the signal type is not supported error: [operator()] Timeout occurred during simulation info: 0 warnings info: 1 errors error: [fmi2logger] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_10_Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.CoolingCoilHumidifyingHeating_ClosedLoop/temp_Buildings_10_Buildings_Applications_DataCenters_ChillerCooled_Equipment_Validation_CoolingCoilHumidifyingHeating_ClosedLoop_fmu/model-1xatbnlx/temp/0001_Buildings_10_Buildings_Applications_DataCenters_ChillerCooled_Equipment_Validation_CoolingCoilHumidifyingHeating_ClosedLoop (logStatusError): fmi2SetContinuousStates: Illegal model exchange call sequence. fmi2SetContinuousStates is not allowed in model_state_terminated state. error: [setContinuousStates] fmi2_setContinuousStates failed for FMU "model.root.Buildings_10_Buildings_Applications_DataCenters_ChillerCooled_Equipment_Validation_CoolingCoilHumidifyingHeating_ClosedLoop"