Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr ThermoSysPro_ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump4.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/package.mo", uses=false) Using package ThermoSysPro with version 4.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/package.mo) Running command: "" <> buildModelFMU(ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump4,fileNamePrefix="ThermoSysPro_ThermoSysPro_Examples_SimpleExamples_TestCentrifugalPump4",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump4,fileNamePrefix="ThermoSysPro_ThermoSysPro_Examples_SimpleExamples_TestCentrifugalPump4",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/package.mo): time 0.8353/0.8353, allocations: 150.9 MB / 166.4 MB, free: 14.25 MB / 142.1 MB Notification: Performance of FrontEnd - loaded program: time 0.0003692/0.0003693, allocations: 23.91 kB / 204.6 MB, free: 9.52 MB / 174.1 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1661/0.1665, allocations: 31.33 MB / 236 MB, free: 5.41 MB / 190.1 MB Notification: Automatically loaded package Complex 4.0.0 due to uses annotation from Modelica. Notification: Automatically loaded package ModelicaServices 4.0.0 due to uses annotation from Modelica. Notification: Automatically loaded package Modelica 4.0.0 due to usage. Notification: Performance of NFInst.instantiate(ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump4): time 1.67/1.836, allocations: 296.5 MB / 0.52 GB, free: 11.55 MB / 414.1 MB Notification: Performance of NFInst.instExpressions: time 0.2121/2.049, allocations: 183.9 MB / 0.6996 GB, free: 3.211 MB / 0.5762 GB Notification: Performance of NFInst.updateImplicitVariability: time 0.0007188/2.049, allocations: 4 kB / 0.6996 GB, free: 3.207 MB / 0.5762 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/CentrifugalPump.mo:118:3-120:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/CentrifugalPump.mo:121:3-123:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/CentrifugalPump.mo:127:3-131:23:writable] Warning: Connector M is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/Tank.mo:71:3-72:53:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/Tank.mo:73:3-74:53:writable] Warning: Connector Cs2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/Tank.mo:78:3-79:55:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/Tank.mo:80:3-81:51:writable] Warning: Connector Cs1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/ControlValve.mo:45:3-47:43:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/ControlValve.mo:48:3-50:38:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/LumpedStraightPipe.mo:49:3-50:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/LumpedStraightPipe.mo:51:3-53:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/ElectroMechanics/BoundaryConditions/SourceMechanicalPower.mo:5:3-9:24:writable] Warning: Connector M is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). Notification: Performance of NFTyping.typeComponents: time 0.0008868/2.05, allocations: 180.6 kB / 0.6998 GB, free: 3.031 MB / 0.5762 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/CentrifugalPump.mo:74:3-74:88:writable] Error: cardinality may only be used in the condition of an if-statement/equation or an assert. Notification: Performance of FrontEnd: time 0.0001438/2.05, allocations: 33.81 kB / 0.6998 GB, free: 2.996 MB / 0.5762 GB