python3 -m fmpy simulate --output-file Buildings_latest_Buildings.Fluid.HeatPumps.Examples.ScrollWaterToWater_OneRoomRadiator_res.csv --start-time 0 --stop-time 172800 --timeout 50 --relative-tolerance 1e-08 --interface-type ModelExchange --solver CVode --output-interval 69.12 Buildings_latest_Buildings_Fluid_HeatPumps_Examples_ScrollWaterToWater_OneRoomRadiator.fmu LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.0.1-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:417:3-427:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((not (pumHeaPum.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.Power_VolumeFlowRate or pumHeaPum.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.EulerNumber))) --> "*** Warning in ScrollWaterToWater_OneRoomRadiator.pumHeaPum: Mover has per.etaHydMet=.Power_VolumeFlowRate or per.etaHydMet=.EulerNumber. | | | | This requires per.pressure to be provided. | | | | Because it is not, the model overrides this setting by using per.etaHydMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.0.1-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:429:3-439:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((pumHeaPum.per.haveWMot_nominal or not (pumHeaPum.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.Efficiency_MotorPartLoadRatio or pumHeaPum.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.GenericCurve))) --> "*** Warning in ScrollWaterToWater_OneRoomRadiator.pumHeaPum: Mover has per.etaMotMet=.Efficiency_MotorPartLoadRatio or per.etaMotMet=.GenericCurve. | | | | This requires per.WMot_nominal or per.pressure to be provided. Because neither is provided, | | | | the model overrides this setting and by using per.etaMotMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.0.1-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:417:3-427:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((not (pumHeaPumSou.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.Power_VolumeFlowRate or pumHeaPumSou.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.EulerNumber))) --> "*** Warning in ScrollWaterToWater_OneRoomRadiator.pumHeaPumSou: Mover has per.etaHydMet=.Power_VolumeFlowRate or per.etaHydMet=.EulerNumber. | | | | This requires per.pressure to be provided. | | | | Because it is not, the model overrides this setting by using per.etaHydMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.0.1-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:429:3-439:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((pumHeaPumSou.per.haveWMot_nominal or not (pumHeaPumSou.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.Efficiency_MotorPartLoadRatio or pumHeaPumSou.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.GenericCurve))) --> "*** Warning in ScrollWaterToWater_OneRoomRadiator.pumHeaPumSou: Mover has per.etaMotMet=.Efficiency_MotorPartLoadRatio or per.etaMotMet=.GenericCurve. | | | | This requires per.WMot_nominal or per.pressure to be provided. Because neither is provided, | | | | the model overrides this setting and by using per.etaMotMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve." LOG_ASSERT | debug | /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_latest_Buildings.Fluid.HeatPumps.Examples.ScrollWaterToWater_OneRoomRadiator/Buildings_latest_Buildings_Fluid_HeatPumps_Examples_ScrollWaterToWater_OneRoomRadiator.fmutmp/sources/Buildings_latest_Buildings_Fluid_HeatPumps_Examples_ScrollWaterToWater_OneRoomRadiator_02nls.c:5816: Invalid root: (1.97046)^(2.77061e+19) LOG_ASSERT | debug | /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_latest_Buildings.Fluid.HeatPumps.Examples.ScrollWaterToWater_OneRoomRadiator/Buildings_latest_Buildings_Fluid_HeatPumps_Examples_ScrollWaterToWater_OneRoomRadiator.fmutmp/sources/Buildings_latest_Buildings_Fluid_HeatPumps_Examples_ScrollWaterToWater_OneRoomRadiator_02nls.c:5816: Invalid root: (1.97046)^(2.57576e+19) LOG_ASSERT | debug | /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_latest_Buildings.Fluid.HeatPumps.Examples.ScrollWaterToWater_OneRoomRadiator/Buildings_latest_Buildings_Fluid_HeatPumps_Examples_ScrollWaterToWater_OneRoomRadiator.fmutmp/sources/Buildings_latest_Buildings_Fluid_HeatPumps_Examples_ScrollWaterToWater_OneRoomRadiator_02nls.c:5816: Invalid root: (1.97046)^(1.33658e+19) LOG_ASSERT | debug | Solving non-linear system 1474 failed at time=811.290792822986. | | | | For more information please use -lv LOG_NLS. Exception ignored on calling ctypes callback function: > Traceback (most recent call last): File "/usr/local/lib/python3.10/dist-packages/fmpy/sundials/__init__.py", line 141, in f self.get_dx(NV_DATA_S(ydot), self.nx) File "/usr/local/lib/python3.10/dist-packages/fmpy/fmi2.py", line 505, in getDerivatives return self.fmi2GetDerivatives(self.component, dx, nx) File "/usr/local/lib/python3.10/dist-packages/fmpy/fmi2.py", line 215, in w raise FMICallException(function=fname, status=res) fmpy.fmi1.FMICallException: fmi2GetDerivatives failed with status 3 (error). Traceback (most recent call last): File "/usr/lib/python3.10/runpy.py", line 196, in _run_module_as_main return _run_code(code, main_globals, None, File "/usr/lib/python3.10/runpy.py", line 86, in _run_code exec(code, run_globals) File "/usr/local/lib/python3.10/dist-packages/fmpy/__main__.py", line 4, in main() File "/usr/local/lib/python3.10/dist-packages/fmpy/command_line.py", line 167, in main result = simulate_fmu(args.fmu_filename, File "/usr/local/lib/python3.10/dist-packages/fmpy/simulation.py", line 759, in simulate_fmu result = simulateME(model_description, fmu, start_time, stop_time, solver, step_size, relative_tolerance, start_values, apply_default_start_values, input, output, output_interval, record_events, timeout, step_finished, validate, set_stop_time) File "/usr/local/lib/python3.10/dist-packages/fmpy/simulation.py", line 1059, in simulateME state_event, roots_found, time = solver.step(time, t_next) File "/usr/local/lib/python3.10/dist-packages/fmpy/sundials/__init__.py", line 178, in step raise RuntimeError("CVode error (code %s) in module %s, function %s: %s" % self.error_info) RuntimeError: CVode error (code -8) in module CVODE, function CVode: At t = 811.291, the right-hand side routine failed in an unrecoverable manner.