Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr Buildings_latest_Buildings.Fluid.Geothermal.ZonedBorefields.Validation.FEFLOW.MassFlowRateStep100.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.0.0-master/package.mo", uses=false) Using package Buildings with version 12.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.0.0-master/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Running command: "" <> buildModelFMU(Buildings.Fluid.Geothermal.ZonedBorefields.Validation.FEFLOW.MassFlowRateStep100,fileNamePrefix="Buildings_latest_Buildings_Fluid_Geothermal_ZonedBorefields_Validation_FEFLOW_MassFlowRateStep100",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(Buildings.Fluid.Geothermal.ZonedBorefields.Validation.FEFLOW.MassFlowRateStep100,fileNamePrefix="Buildings_latest_Buildings_Fluid_Geothermal_ZonedBorefields_Validation_FEFLOW_MassFlowRateStep100",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.001315/0.001315, allocations: 108 kB / 15.6 MB, free: 132 kB / 14.72 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.00126/0.00126, allocations: 191 kB / 16.53 MB, free: 6.391 MB / 14.72 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.412/1.412, allocations: 222.9 MB / 240.2 MB, free: 4.402 MB / 190.1 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.0.0-master/package.mo): time 2.864/2.864, allocations: 482.6 MB / 0.7549 GB, free: 10.63 MB / 0.6075 GB Notification: Performance of FrontEnd - loaded program: time 0.002762/0.002762, allocations: 66.16 kB / 0.9242 GB, free: 29.25 MB / 0.7169 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2933/0.296, allocations: 162.3 MB / 1.083 GB, free: 12.81 MB / 0.8419 GB Notification: Performance of NFInst.instantiate(Buildings.Fluid.Geothermal.ZonedBorefields.Validation.FEFLOW.MassFlowRateStep100): time 0.101/0.3971, allocations: 97.86 MB / 1.178 GB, free: 10.62 MB / 0.9356 GB Notification: Performance of NFInst.instExpressions: time 0.04664/0.4437, allocations: 32.25 MB / 1.21 GB, free: 10.28 MB / 0.9669 GB Notification: Performance of NFInst.updateImplicitVariability: time 0.004546/0.4483, allocations: 135.3 kB / 1.21 GB, free: 10.14 MB / 0.9669 GB Notification: Performance of NFTyping.typeComponents: time 0.007271/0.4556, allocations: 2.651 MB / 1.212 GB, free: 7.48 MB / 0.9669 GB Notification: Performance of NFTyping.typeBindings: time 0.0129/0.4685, allocations: 4.906 MB / 1.217 GB, free: 2.555 MB / 0.9669 GB Notification: Performance of NFTyping.typeClassSections: time 0.01318/0.4817, allocations: 5.419 MB / 1.223 GB, free: 13.17 MB / 0.9825 GB [/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/Compiler/NFFrontEnd/NFExpression.mo:1588:7-1589:100:writable] Error: Internal error NFExpression.makeSubscriptedExp: too few dimensions in Buildings.Fluid.Geothermal.Borefields.Data.Configuration.Template(Buildings.Fluid.Geothermal.Borefields.Types.BoreholeConfiguration.DoubleUTubeParallel, false, 0.0, {0.2304597222222222, 0.2304597222222222}[], {5.531033333333334, 0.921838888888889}[], {34000.0, 34000.0}[], 85.0, 0.075, 0.5, {24, 4}[], {{3.0, 1.5}, {6.0, 1.5}, {9.0, 1.5}, {12.0, 1.5}, {1.5, 4.5}, {4.5, 4.5}, {7.5, 4.5}, {10.5, 4.5}, {3.0, 7.5}, {6.0, 7.5}, {9.0, 7.5}, {12.0, 7.5}, {1.5, 10.5}, {4.5, 10.5}, {7.5, 10.5}, {10.5, 10.5}, {3.0, 13.5}, {6.0, 13.5}, {9.0, 13.5}, {12.0, 13.5}, {1.5, 16.5}, {4.5, 16.5}, {7.5, 16.5}, {10.5, 16.5}, {5.4, 22.5}, {10.8, 22.5}, {2.7, 28.5}, {8.1, 28.5}}, 0.016, 0.42, 0.0029, 0.0282842712474619, {2.304597222222223e-05, 2.304597222222223e-05}[]) to apply subscripts [] [/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/Compiler/NFFrontEnd/NFCeval.mo:1731:9-1732:93:writable] Error: Internal error NFCeval.evalRelationEqual failed to evaluate ‘borFie.borHol.borFieDat.conDat.borCon == Buildings.Fluid.Geothermal.Borefields.Types.BoreholeConfiguration.DoubleUTubeParallel‘ [/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/Compiler/NFFrontEnd/NFCeval.mo:1494:9-1494:67:writable] Error: Internal error NFCeval.evalLogicBinaryAnd failed to evaluate ‘true and borFie.borHol.borFieDat.conDat.borCon == Buildings.Fluid.Geothermal.Borefields.Types.BoreholeConfiguration.DoubleUTubeParallel‘ Notification: Performance of FrontEnd: time 0.00961/0.4913, allocations: 7.188 MB / 1.23 GB, free: 5.973 MB / 0.9825 GB