Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr TransiEnt_TransiEnt.Examples.Coupled.Coupled_ElectricGrid_GasGrid.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.2/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/DymolaCommands master/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.1-main/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaReference 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_LinearSystems2 2.4.0/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_StateGraph2 2.1.0/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Design master/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/DataFiles master/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/package.mo", uses=false) Using package TransiEnt with version 2.0.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/package.mo) Using package DataFiles with version 0.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/DataFiles master/package.mo) Using package Design with version 0.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Design master/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Using package Modelica_StateGraph2 with version 2.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_StateGraph2 2.1.0/package.mo) Using package Modelica_LinearSystems2 with version 2.4.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_LinearSystems2 2.4.0/package.mo) Using package ModelicaReference with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaReference 4.0.0+maint.om/package.mo) Using package TILMedia with version 1.8.1 ClaRa (/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.1-main/package.mo) Using package ClaRa with version 1.8.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/package.mo) Using package DymolaCommands with version 0.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/DymolaCommands master/package.mo) Using package Buildings with version 9.1.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.2/package.mo) Running command: translateModel(TransiEnt.Examples.Coupled.Coupled_ElectricGrid_GasGrid,tolerance=1e-06,outputFormat="empty",numberOfIntervals=576,variableFilter="",fileNamePrefix="TransiEnt_TransiEnt.Examples.Coupled.Coupled_ElectricGrid_GasGrid") translateModel(TransiEnt.Examples.Coupled.Coupled_ElectricGrid_GasGrid,tolerance=1e-06,outputFormat="empty",numberOfIntervals=576,variableFilter="",fileNamePrefix="TransiEnt_TransiEnt.Examples.Coupled.Coupled_ElectricGrid_GasGrid") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.2/package.mo): time 2.318/2.318, allocations: 389.5 MB / 409 MB, free: 12.78 MB / 318.1 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/DymolaCommands master/package.mo): time 0.0006499/0.0006497, allocations: 43.86 kB / 0.489 GB, free: 4.855 MB / 398.1 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Control/PredictorModels_3508/Check/package.mo:2:1-21:10:writable] Warning: The package.order file contains a class TestReheater, which is expected to be stored in file TestReheater.mo, but seems to be named testReheater.mo. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Control/PredictorModels_3508/Check/testReheater.mo:2:1-117:17:writable] Warning: Expected the package to have name testReheater, but got TestReheater. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/package.mo:2:1-23:10:writable] Warning: PhysicalMills was referenced in the package.order file, but was not found in package.mo, PhysicalMills/package.mo or PhysicalMills.mo. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/package.mo:2:1-22:18:writable] Warning: Expected the package to have name physicalMills, but got PhysicalMills. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/package.mo:2:1-22:18:writable] Warning: The package.order file contains a class Mill_L4_advancedInit, which is expected to be stored in file Mill_L4_advancedInit.mo, but seems to be named mill_L4_advancedInit.mo. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/package.mo:2:1-22:18:writable] Warning: The package.order file contains a class Mill_L4, which is expected to be stored in file Mill_L4.mo, but seems to be named mill_L4.mo. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/mill_L4_advancedInit.mo:2:1-58:25:writable] Warning: Expected the package to have name mill_L4_advancedInit, but got Mill_L4_advancedInit. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/mill_L4_advancedInit.mo:2:1-58:25:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills; but got within ClaRa.Components.Mills.PhysicalMills; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/mill_L4.mo:2:1-315:12:writable] Warning: Expected the package to have name mill_L4, but got Mill_L4. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/mill_L4.mo:2:1-315:12:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills; but got within ClaRa.Components.Mills.PhysicalMills; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Check/package.mo:2:1-21:10:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills; but got within ClaRa.Components.Mills.PhysicalMills; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Check/package.mo:2:1-21:10:writable] Warning: The package.order file contains a class TestMillBox_2, which is expected to be stored in file TestMillBox_2.mo, but seems to be named testMillBox_2.mo. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Check/package.mo:2:1-21:10:writable] Warning: The package.order file contains a class TestMillBox_1_measurementInput, which is expected to be stored in file TestMillBox_1_measurementInput.mo, but seems to be named testMillBox_1_measurementInput.mo. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Check/package.mo:2:1-21:10:writable] Warning: The package.order file contains a class TestMillBox_1, which is expected to be stored in file TestMillBox_1.mo, but seems to be named testMillBox_1.mo. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Check/testMillBox_2.mo:2:1-297:18:writable] Warning: Expected the package to have name testMillBox_2, but got TestMillBox_2. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Check/testMillBox_2.mo:2:1-297:18:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Check; but got within ClaRa.Components.Mills.PhysicalMills.Check; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Check/testMillBox_1_measurementInput.mo:2:1-1342:35:writable] Warning: Expected the package to have name testMillBox_1_measurementInput, but got TestMillBox_1_measurementInput. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Check/testMillBox_1_measurementInput.mo:2:1-1342:35:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Check; but got within ClaRa.Components.Mills.PhysicalMills.Check; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Check/testMillBox_1.mo:2:1-465:18:writable] Warning: Expected the package to have name testMillBox_1, but got TestMillBox_1. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Check/testMillBox_1.mo:2:1-465:18:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Check; but got within ClaRa.Components.Mills.PhysicalMills.Check; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/package.mo:2:1-29:12:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills; but got within ClaRa.Components.Mills.PhysicalMills; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/FlowClassifier.mo:2:1-346:19:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes; but got within ClaRa.Components.Mills.PhysicalMills.Volumes; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/CentrifugalClassifier.mo:2:1-380:26:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes; but got within ClaRa.Components.Mills.PhysicalMills.Volumes; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/GrinderRingRoller.mo:2:1-294:22:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes; but got within ClaRa.Components.Mills.PhysicalMills.Volumes; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/FuelJoin_distributed.mo:2:1-133:25:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes; but got within ClaRa.Components.Mills.PhysicalMills.Volumes; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Dryer.mo:2:1-301:10:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes; but got within ClaRa.Components.Mills.PhysicalMills.Volumes; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/package.mo:2:1-20:17:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes; but got within ClaRa.Components.Mills.PhysicalMills.Volumes; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/package.mo:2:1-20:13:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Transport_Velocity/package.mo:2:1-20:23:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Transport_Velocity/Transport_complex.mo:2:1-71:22:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Transport_Velocity; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Transport_Velocity; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Transport_Velocity/Transport_constant.mo:2:1-49:23:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Transport_Velocity; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Transport_Velocity; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Transport_Velocity/Transport_base.mo:2:1-52:19:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Transport_Velocity; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Transport_Velocity; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Selection_Function/package.mo:2:1-20:23:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Selection_Function/Selection_Kersting.mo:2:1-80:23:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Selection_Function; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Selection_Function; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Selection_Function/Selection_Steinmetz.mo:2:1-104:24:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Selection_Function; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Selection_Function; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Selection_Function/Selection_constant.mo:2:1-45:23:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Selection_Function; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Selection_Function; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Selection_Function/Selection_base.mo:2:1-50:19:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Selection_Function; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Selection_Function; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Breakage_Function/package.mo:2:1-20:22:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Breakage_Function/Breakage_Austin.mo:2:1-109:20:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Breakage_Function; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Breakage_Function; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Breakage_Function/Breakage_Steinmetz.mo:2:1-106:23:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Breakage_Function; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Breakage_Function; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Breakage_Function/Breakage_constant.mo:2:1-45:22:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Breakage_Function; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Breakage_Function; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Breakage_Function/Breakage_base.mo:2:1-51:18:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Breakage_Function; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Breakage_Function; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Drying/package.mo:2:1-20:11:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Drying/Drying_ideal.mo:2:1-58:17:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Drying; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Drying; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Drying/Drying_base.mo:2:1-44:16:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Drying; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Drying; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Classifying/package.mo:2:1-20:16:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Classifying/Classifying_flow.mo:2:1-111:21:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Classifying; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Classifying; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Classifying/Classifying_centrifugal.mo:2:1-153:28:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Classifying; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Classifying; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Classifying/Classifying_centrifugal_base.mo:2:1-45:33:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Classifying; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Classifying; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Classifying/Classifying_flow_base.mo:2:1-45:26:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Classifying; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Classifying; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Records/package.mo:2:1-20:12:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Records/iCom_Dryer.mo:2:1-57:15:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Records; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Records; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Records/iCom_FlowClassifier.mo:2:1-67:24:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Records; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Records; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Records/iCom_CentrifugalClassifier.mo:2:1-69:31:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Records; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Records; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Records/iCom_Grinder.mo:2:1-61:17:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Records; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Records; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Records/FuelClassification_example_21classes.mo:2:1-43:41:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Records; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Records; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Records/GeometricProgression.mo:2:1-56:25:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Records; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Records; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Records/FuelClassification_generic.mo:2:1-43:31:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Records; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Records; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Records/FuelClassification_example_05classes.mo:2:1-43:41:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Records; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Records; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Records/FuelClassification_example_11classes.mo:2:1-43:41:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Records; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Records; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Records/FuelClassification_base.mo:2:1-61:28:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Records; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Records; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Check/package.mo:2:1-23:10:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes; but got within ClaRa.Components.Mills.PhysicalMills.Volumes; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Check/package.mo:2:1-23:10:writable] Warning: The package.order file contains a class TestFuelJoin, which is expected to be stored in file TestFuelJoin.mo, but seems to be named testFuelJoin.mo. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Check/package.mo:2:1-23:10:writable] Warning: The package.order file contains a class TestAerosolVolume, which is expected to be stored in file TestAerosolVolume.mo, but seems to be named testAerosolVolume.mo. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Check/package.mo:2:1-23:10:writable] Warning: The package.order file contains a class TestDryer, which is expected to be stored in file TestDryer.mo, but seems to be named testDryer.mo. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Check/package.mo:2:1-23:10:writable] Warning: The package.order file contains a class TestGrinder, which is expected to be stored in file TestGrinder.mo, but seems to be named testGrinder.mo. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Check/testFuelJoin.mo:2:1-93:17:writable] Warning: Expected the package to have name testFuelJoin, but got TestFuelJoin. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Check/testFuelJoin.mo:2:1-93:17:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Check; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Check; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Check/testAerosolVolume.mo:2:1-176:22:writable] Warning: Expected the package to have name testAerosolVolume, but got TestAerosolVolume. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Check/testAerosolVolume.mo:2:1-176:22:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Check; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Check; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Check/testDryer.mo:2:1-93:14:writable] Warning: Expected the package to have name testDryer, but got TestDryer. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Check/testDryer.mo:2:1-93:14:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Check; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Check; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Check/testGrinder.mo:2:1-154:16:writable] Warning: Expected the package to have name testGrinder, but got TestGrinder. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Check/testGrinder.mo:2:1-154:16:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Check; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Check; (ignoring the potential error; the class might have been inserted at an unexpected location). Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/package.mo): time 0.7273/0.7273, allocations: 127.2 MB / 0.7027 GB, free: 5.605 MB / 0.4981 GB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.1-main/package.mo): time 0.1109/0.1109, allocations: 22.36 MB / 0.8394 GB, free: 16.49 MB / 0.5294 GB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaReference 4.0.0+maint.om/package.mo): time 0.0108/0.0108, allocations: 0.8798 MB / 0.9614 GB, free: 3.445 MB / 0.6388 GB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_LinearSystems2 2.4.0/package.mo): time 0.2683/0.2683, allocations: 45.02 MB / 1.127 GB, free: 97.89 MB / 0.6544 GB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_StateGraph2 2.1.0/package.mo): time 0.09923/0.09923, allocations: 13.55 MB / 1.27 GB, free: 93.63 MB / 0.6544 GB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.001374/0.001374, allocations: 114.5 kB / 1.403 GB, free: 7.238 MB / 0.7013 GB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001538/0.001538, allocations: 186.6 kB / 1.536 GB, free: 222.8 MB / 0.8263 GB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.774/1.774, allocations: 222.9 MB / 1.886 GB, free: 91.96 MB / 0.8888 GB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Design master/package.mo): time 0.0006552/0.0006552, allocations: 31.94 kB / 2.068 GB, free: 15.2 MB / 0.92 GB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/DataFiles master/package.mo): time 0.0008299/0.0008298, allocations: 31.94 kB / 2.249 GB, free: 5.41 MB / 1.092 GB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/package.mo): time 1.102/1.102, allocations: 220.8 MB / 2.646 GB, free: 132.2 MB / 1.123 GB Warning: Ignoring unknown experiment annotation option: __Dymola_Algorithm = "Sdirk34hw" Warning: Requested package TILMedia of version 1.8.0 ClaRa, but this package was already loaded with version 1.8.1 ClaRa. OpenModelica cannot reason about compatibility between the two packages since they are not semantic versions. Warning: TransiEnt requested package ClaRa of version 1.8.0. ClaRa 1.8.1 is used instead which states that it is only compatible with a conversion script. Use convertPackageToLibrary(TransiEnt, ClaRa, "1.8.1") to run the conversion script or proceed with potential issues as a result. Notification: TransiEnt requested package Buildings of version 9.0.0. Buildings 9.1.2 is used instead which states that it is fully compatible without conversion script needed. Notification: Performance of FrontEnd - loaded program: time 0.006087/0.006087, allocations: 310.8 kB / 2.893 GB, free: 111.1 MB / 1.123 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.6065/0.6126, allocations: 229.5 MB / 3.117 GB, free: 11.23 MB / 1.233 GB Notification: Performance of NFInst.instantiate(TransiEnt.Examples.Coupled.Coupled_ElectricGrid_GasGrid): time 0.1806/0.7933, allocations: 146.9 MB / 3.261 GB, free: 7.727 MB / 1.373 GB Notification: Performance of NFInst.instExpressions: time 2.369/3.163, allocations: 72.08 MB / 3.331 GB, free: 6.246 MB / 1.389 GB Notification: Performance of NFInst.updateImplicitVariability: time 0.05958/3.222, allocations: 0.7462 MB / 3.332 GB, free: 6.242 MB / 1.389 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/SimCenter.mo:69:5-70:35:writable] Warning: Connector cycleSumPort is not balanced: The number of potential variables (0) is not equal to the number of flow variables (4). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/ModelStatistics.mo:85:3-85:105:writable] Warning: Connector powerCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/ModelStatistics.mo:86:3-86:112:writable] Warning: Connector primBalPowerCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/ModelStatistics.mo:87:3-87:102:writable] Warning: Connector primBalPowerOfferCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/ModelStatistics.mo:88:3-88:111:writable] Warning: Connector secBalPowerCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/ModelStatistics.mo:89:3-89:101:writable] Warning: Connector secBalPowerOfferCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/ModelStatistics.mo:90:3-90:92:writable] Warning: Connector surroundingGridLoad is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/ModelStatistics.mo:92:3-92:126:writable] Warning: Connector tielinePowerCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/ModelStatistics.mo:93:3-93:130:writable] Warning: Connector tielineSetPowerCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/ModelStatistics.mo:95:3-95:95:writable] Warning: Connector kineticEnergyCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/ModelStatistics.mo:98:3-98:99:writable] Warning: Connector gwpCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/ModelStatistics.mo:100:3-100:107:writable] Warning: Connector gwpCollectorHeat is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/ModelStatistics.mo:103:3-103:82:writable] Warning: Connector heatFlowCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/ModelStatistics.mo:105:3-105:87:writable] Warning: Connector costsCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (6). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Statistics/Collectors/LocalCollectors/CollectElectricPower.mo:67:3-67:137:writable] Warning: Connector powerCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Statistics/Collectors/LocalCollectors/CollectHeatingPower.mo:68:3-68:143:writable] Warning: Connector heatFlowCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Statistics/Collectors/LocalCollectors/CollectGwpEmissionsElectric.mo:73:3-73:141:writable] Warning: Connector gwpCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Statistics/Collectors/LocalCollectors/PartialCollectCosts.mo:122:3-122:137:writable] Warning: Connector costsCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (6). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Statistics/Collectors/LocalCollectors/CollectHeatingPower.mo:68:3-68:143:writable] Warning: Connector heatFlowCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Statistics/Collectors/LocalCollectors/PartialCollectCosts.mo:122:3-122:137:writable] Warning: Connector costsCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (6). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Statistics/Collectors/LocalCollectors/CollectGwpEmissionsElectric.mo:73:3-73:141:writable] Warning: Connector gwpCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Statistics/Collectors/LocalCollectors/CollectElectricPower.mo:67:3-67:137:writable] Warning: Connector powerCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/ModelStatistics.mo:85:3-85:105:writable] Warning: Connector powerCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/ModelStatistics.mo:86:3-86:112:writable] Warning: Connector primBalPowerCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/ModelStatistics.mo:87:3-87:102:writable] Warning: Connector primBalPowerOfferCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/ModelStatistics.mo:88:3-88:111:writable] Warning: Connector secBalPowerCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/ModelStatistics.mo:89:3-89:101:writable] Warning: Connector secBalPowerOfferCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/ModelStatistics.mo:90:3-90:92:writable] Warning: Connector surroundingGridLoad is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/ModelStatistics.mo:92:3-92:126:writable] Warning: Connector tielinePowerCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/ModelStatistics.mo:93:3-93:130:writable] Warning: Connector tielineSetPowerCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/ModelStatistics.mo:95:3-95:95:writable] Warning: Connector kineticEnergyCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/ModelStatistics.mo:98:3-98:99:writable] Warning: Connector gwpCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/ModelStatistics.mo:100:3-100:107:writable] Warning: Connector gwpCollectorHeat is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/ModelStatistics.mo:103:3-103:82:writable] Warning: Connector heatFlowCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/ModelStatistics.mo:105:3-105:87:writable] Warning: Connector costsCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (6). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Statistics/Collectors/LocalCollectors/CollectElectricPower.mo:67:3-67:137:writable] Warning: Connector powerCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Statistics/Collectors/LocalCollectors/CollectGwpEmissionsElectric.mo:73:3-73:141:writable] Warning: Connector gwpCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Statistics/Collectors/LocalCollectors/PartialCollectCosts.mo:122:3-122:137:writable] Warning: Connector costsCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (6). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Statistics/Collectors/LocalCollectors/CollectElectricPower.mo:67:3-67:137:writable] Warning: Connector powerCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Statistics/Collectors/LocalCollectors/CollectKineticEnergy.mo:38:3-38:143:writable] Warning: Connector kineticEnergyCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Statistics/Collectors/LocalCollectors/CollectElectricPower.mo:67:3-67:137:writable] Warning: Connector powerCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Statistics/Collectors/LocalCollectors/CollectKineticEnergy.mo:38:3-38:143:writable] Warning: Connector kineticEnergyCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Statistics/Collectors/LocalCollectors/CollectElectricPower.mo:67:3-67:137:writable] Warning: Connector powerCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Statistics/Collectors/LocalCollectors/CollectGwpEmissionsElectric.mo:73:3-73:141:writable] Warning: Connector gwpCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Statistics/Collectors/LocalCollectors/PartialCollectCosts.mo:122:3-122:137:writable] Warning: Connector costsCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (6). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Statistics/Collectors/LocalCollectors/CollectElectricPower.mo:67:3-67:137:writable] Warning: Connector powerCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Statistics/Collectors/LocalCollectors/CollectGwpEmissionsElectric.mo:73:3-73:141:writable] Warning: Connector gwpCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Statistics/Collectors/LocalCollectors/PartialCollectCosts.mo:122:3-122:137:writable] Warning: Connector costsCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (6). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Grid/Gas/StaticCycles/Source_yellow_T.mo:49:3-59:25:writable] Warning: Connector outlet is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Grid/Gas/StaticCycles/Sink_yellow.mo:43:3-49:26:writable] Warning: Connector inlet is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Grid/Gas/StaticCycles/Split.mo:47:3-53:26:writable] Warning: Connector inlet is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Grid/Gas/StaticCycles/Split.mo:54:3-64:27:writable] Warning: Connector outlet1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Grid/Gas/StaticCycles/Split.mo:65:3-75:26:writable] Warning: Connector outlet2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Grid/Gas/StaticCycles/Pipe_yellow.mo:56:3-62:26:writable] Warning: Connector inlet is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Grid/Gas/StaticCycles/Pipe_yellow.mo:63:3-73:26:writable] Warning: Connector outlet is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Grid/Gas/StaticCycles/Pipe_yellow.mo:56:3-62:26:writable] Warning: Connector inlet is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Grid/Gas/StaticCycles/Pipe_yellow.mo:63:3-73:26:writable] Warning: Connector outlet is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Grid/Gas/StaticCycles/Pipe_yellow.mo:56:3-62:26:writable] Warning: Connector inlet is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Grid/Gas/StaticCycles/Pipe_yellow.mo:63:3-73:26:writable] Warning: Connector outlet is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Grid/Gas/StaticCycles/Pipe_yellow.mo:56:3-62:26:writable] Warning: Connector inlet is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Grid/Gas/StaticCycles/Pipe_yellow.mo:63:3-73:26:writable] Warning: Connector outlet is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Grid/Gas/StaticCycles/Split.mo:47:3-53:26:writable] Warning: Connector inlet is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Grid/Gas/StaticCycles/Split.mo:54:3-64:27:writable] Warning: Connector outlet1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Grid/Gas/StaticCycles/Split.mo:65:3-75:26:writable] Warning: Connector outlet2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Grid/Gas/StaticCycles/Valve_cutFlow.mo:48:3-54:27:writable] Warning: Connector inlet is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Grid/Gas/StaticCycles/Valve_cutFlow.mo:55:3-64:25:writable] Warning: Connector outlet is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Grid/Gas/StaticCycles/Mixer1.mo:54:3-61:73:writable] Warning: Connector outlet is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Grid/Gas/StaticCycles/Mixer1.mo:62:3-68:27:writable] Warning: Connector inlet1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Grid/Gas/StaticCycles/Mixer1.mo:69:3-78:26:writable] Warning: Connector inlet2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Grid/Gas/StaticCycles/Mixer1.mo:54:3-61:73:writable] Warning: Connector outlet is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Grid/Gas/StaticCycles/Mixer1.mo:62:3-68:27:writable] Warning: Connector inlet1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Grid/Gas/StaticCycles/Mixer1.mo:69:3-78:26:writable] Warning: Connector inlet2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Grid/Gas/StaticCycles/Valve_cutFlow.mo:48:3-54:27:writable] Warning: Connector inlet is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Grid/Gas/StaticCycles/Valve_cutFlow.mo:55:3-64:25:writable] Warning: Connector outlet is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Grid/Gas/StaticCycles/Source_blue.mo:46:3-56:25:writable] Warning: Connector outlet is not balanced: The number of potential variables (3) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Grid/Gas/StaticCycles/Mixer2.mo:53:3-63:26:writable] Warning: Connector outlet is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Grid/Gas/StaticCycles/Mixer2.mo:64:3-70:27:writable] Warning: Connector inlet1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Grid/Gas/StaticCycles/Mixer2.mo:71:3-77:26:writable] Warning: Connector inlet2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Grid/Gas/StaticCycles/Source_blue.mo:46:3-56:25:writable] Warning: Connector outlet is not balanced: The number of potential variables (3) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Grid/Gas/StaticCycles/Mixer2.mo:53:3-63:26:writable] Warning: Connector outlet is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Grid/Gas/StaticCycles/Mixer2.mo:64:3-70:27:writable] Warning: Connector inlet1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Grid/Gas/StaticCycles/Mixer2.mo:71:3-77:26:writable] Warning: Connector inlet2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Grid/Gas/StaticCycles/Adapter_H2toNG.mo:47:3-53:26:writable] Warning: Connector inlet is not balanced: The number of potential variables (3) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Grid/Gas/StaticCycles/Adapter_H2toNG.mo:54:3-64:25:writable] Warning: Connector outlet is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Grid/Gas/StaticCycles/Adapter_H2toNG.mo:47:3-53:26:writable] Warning: Connector inlet is not balanced: The number of potential variables (3) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Grid/Gas/StaticCycles/Adapter_H2toNG.mo:54:3-64:25:writable] Warning: Connector outlet is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Statistics/Collectors/LocalCollectors/CollectElectricPower.mo:67:3-67:137:writable] Warning: Connector powerCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Statistics/Collectors/LocalCollectors/PartialCollectCosts.mo:122:3-122:137:writable] Warning: Connector costsCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (6). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Statistics/Collectors/LocalCollectors/CollectElectricPower.mo:67:3-67:137:writable] Warning: Connector powerCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Statistics/Collectors/LocalCollectors/PartialCollectCosts.mo:122:3-122:137:writable] Warning: Connector costsCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (6). Notification: Performance of NFTyping.typeComponents: time 0.05442/3.277, allocations: 14.11 MB / 3.346 GB, free: 3.25 MB / 1.389 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Basics/Functions/fullPathName.mo:2:1-78:17:writable] Warning: Pure function 'TransiEnt.Basics.Functions.fullPathName' contains a call to impure function 'Modelica.Utilities.Streams.print'. Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.BrownCoal as Integer: 1. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.BrownCoal) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.BlackCoal as Integer: 2. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.BlackCoal) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.NaturalGas as Integer: 3. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.NaturalGas) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.WindOnshore as Integer: 4. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.WindOnshore) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.WindOffshore as Integer: 5. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.WindOffshore) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.Solar as Integer: 6. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.Solar) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.Hydro as Integer: 7. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.Hydro) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.Nuclear as Integer: 8. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.Nuclear) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.Oil as Integer: 9. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.Oil) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.NaturalGas as Integer: 3. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.NaturalGas) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.DistrictHeating as Integer: 4. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.DistrictHeating) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.Oil as Integer: 5. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.Oil) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.Electricity as Integer: 6. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.Electricity) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.Solar as Integer: 7. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.Solar) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.Biomass as Integer: 8. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.Biomass) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.Others as Integer: 10. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.Others) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Consumer as Integer: 1. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Consumer) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Conventional as Integer: 2. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Conventional) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Cogeneration as Integer: 3. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Cogeneration) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Renewable as Integer: 4. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Renewable) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Consumer as Integer: 1. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Consumer) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Generic as Integer: 6. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Generic) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Consumer as Integer: 1. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Consumer) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Renewable as Integer: 4. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Renewable) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Cogeneration as Integer: 3. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Cogeneration) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Conventional as Integer: 2. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Conventional) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Cogeneration as Integer: 3. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Cogeneration) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Conventional as Integer: 2. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Conventional) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Storage as Integer: 5. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Storage) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Consumer as Integer: 1. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Consumer) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Conventional as Integer: 2. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Conventional) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Cogeneration as Integer: 3. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Cogeneration) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Renewable as Integer: 4. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Renewable) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Generic as Integer: 6. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Generic) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Consumer as Integer: 1. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Consumer) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Conventional as Integer: 2. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Conventional) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Cogeneration as Integer: 3. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Cogeneration) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Renewable as Integer: 4. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Renewable) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Generic as Integer: 6. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Generic) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Consumer as Integer: 1. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Consumer) instead! [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.1-main/VLEFluidFunctions.mo:524:13-528:28:writable] Warning: Pure function 'TILMedia.Internals.VLEFluidConfigurations.FullyMixtureCompatible.VLEFluidFunctions.specificEnthalpy_pTxi' contains a call to impure function 'TILMedia.Internals.VLEFluidFunctions.specificEnthalpy_pTxi'. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.1-main/VLEFluidFunctions.mo:177:13-181:19:writable] Warning: Pure function 'TILMedia.Internals.VLEFluidConfigurations.FullyMixtureCompatible.VLEFluidFunctions.density_phxi' contains a call to impure function 'TILMedia.Internals.VLEFluidFunctions.density_phxi'. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Producer/Heat/Gas2Heat/SimpleGasBoiler/SimpleBoiler.mo:111:88-111:121:writable] Warning: Conditional component 'massflowSensor' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Basics/Blocks/FirstOrder.mo:41:14-41:82:writable] Warning: In relation gasBoiler.nCVController.LimPID.smoothPIDInput.Tau == 0.0, == on Real numbers is only allowed inside functions. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Basics/Blocks/FirstOrder.mo:41:14-41:82:writable] Warning: In relation gasBoiler.nCVController.LimPID.smoothPIDOutput.Tau == 0.0, == on Real numbers is only allowed inside functions. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Basics/Blocks/FirstOrder.mo:41:14-41:82:writable] Warning: In relation gasBoiler.nCVController.LimPID.smoothPIDOutput1.Tau == 0.0, == on Real numbers is only allowed inside functions. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Producer/Heat/Gas2Heat/SimpleGasBoiler/SimpleBoiler.mo:135:57-135:67:writable] Warning: Conditional component 'outlet' is used in a non-connect context. Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.BrownCoal as Integer: 1. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.BrownCoal) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.BlackCoal as Integer: 2. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.BlackCoal) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.NaturalGas as Integer: 3. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.NaturalGas) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.WindOnshore as Integer: 4. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.WindOnshore) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.WindOffshore as Integer: 5. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.WindOffshore) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.Solar as Integer: 6. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.Solar) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.Hydro as Integer: 7. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.Hydro) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.Nuclear as Integer: 8. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.Nuclear) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.Oil as Integer: 9. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.Oil) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.NaturalGas as Integer: 3. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.NaturalGas) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.DistrictHeating as Integer: 4. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.DistrictHeating) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.Oil as Integer: 5. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.Oil) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.Electricity as Integer: 6. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.Electricity) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.Solar as Integer: 7. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.Solar) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.Biomass as Integer: 8. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.Biomass) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.Others as Integer: 10. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.Others) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Consumer as Integer: 1. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Consumer) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Conventional as Integer: 2. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Conventional) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Cogeneration as Integer: 3. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Cogeneration) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Renewable as Integer: 4. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Renewable) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Consumer as Integer: 1. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Consumer) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Generic as Integer: 6. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Generic) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Consumer as Integer: 1. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Consumer) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Renewable as Integer: 4. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Renewable) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Cogeneration as Integer: 3. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Cogeneration) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Conventional as Integer: 2. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Conventional) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Cogeneration as Integer: 3. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Cogeneration) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Conventional as Integer: 2. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Conventional) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Storage as Integer: 5. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Storage) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Consumer as Integer: 1. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Consumer) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Conventional as Integer: 2. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Conventional) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Cogeneration as Integer: 3. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Cogeneration) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Renewable as Integer: 4. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Renewable) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Generic as Integer: 6. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Generic) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Consumer as Integer: 1. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Consumer) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Conventional as Integer: 2. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Conventional) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Cogeneration as Integer: 3. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Cogeneration) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Renewable as Integer: 4. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Renewable) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Generic as Integer: 6. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Generic) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Consumer as Integer: 1. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Consumer) instead! [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.1-main/VLEFluidFunctions.mo:187:13-191:23:writable] Warning: Pure function 'TILMedia.Internals.VLEFluidConfigurations.FullyMixtureCompatible.VLEFluidFunctions.temperature_phxi' contains a call to impure function 'TILMedia.Internals.VLEFluidFunctions.temperature_phxi'. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Basics/Blocks/FirstOrder.mo:41:14-41:82:writable] Warning: In relation gasGrid_subSystem.feedInStation1.controlTotalEly.controlElyMaximumFeedIn.limPID.smoothPIDInput.Tau == 0.0, == on Real numbers is only allowed inside functions. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Basics/Blocks/FirstOrder.mo:41:14-41:82:writable] Warning: In relation gasGrid_subSystem.feedInStation1.controlTotalEly.controlElyMaximumFeedIn.limPID.smoothPIDOutput.Tau == 0.0, == on Real numbers is only allowed inside functions. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Basics/Blocks/FirstOrder.mo:41:14-41:82:writable] Warning: In relation gasGrid_subSystem.feedInStation1.controlTotalEly.controlElyMaximumFeedIn.limPID.smoothPIDOutput1.Tau == 0.0, == on Real numbers is only allowed inside functions. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Producer/Gas/Electrolyzer/Controller/FeedInController.mo:115:63-115:130:writable] Warning: Conditional component 'm_flow_feedIn' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Producer/Gas/Electrolyzer/Systems/FeedInStation_woStorage.mo:188:7-188:42:writable] Warning: Conditional component 'T' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Producer/Gas/Electrolyzer/Systems/FeedInStation_woStorage.mo:186:7-186:42:writable] Warning: Conditional component 'x' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Producer/Gas/Electrolyzer/Systems/FeedInStation_woStorage.mo:191:7-191:46:writable] Warning: Conditional component 'rho' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Basics/Blocks/FirstOrder.mo:41:14-41:82:writable] Warning: In relation gasGrid_subSystem.feedInStation2.controlTotalEly.controlElyMaximumFeedIn.limPID.smoothPIDInput.Tau == 0.0, == on Real numbers is only allowed inside functions. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Basics/Blocks/FirstOrder.mo:41:14-41:82:writable] Warning: In relation gasGrid_subSystem.feedInStation2.controlTotalEly.controlElyMaximumFeedIn.limPID.smoothPIDOutput.Tau == 0.0, == on Real numbers is only allowed inside functions. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Basics/Blocks/FirstOrder.mo:41:14-41:82:writable] Warning: In relation gasGrid_subSystem.feedInStation2.controlTotalEly.controlElyMaximumFeedIn.limPID.smoothPIDOutput1.Tau == 0.0, == on Real numbers is only allowed inside functions. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Producer/Gas/Electrolyzer/Controller/FeedInController.mo:115:63-115:130:writable] Warning: Conditional component 'm_flow_feedIn' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Producer/Gas/Electrolyzer/Systems/FeedInStation_woStorage.mo:188:7-188:42:writable] Warning: Conditional component 'T' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Producer/Gas/Electrolyzer/Systems/FeedInStation_woStorage.mo:186:7-186:42:writable] Warning: Conditional component 'x' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Producer/Gas/Electrolyzer/Systems/FeedInStation_woStorage.mo:191:7-191:46:writable] Warning: Conditional component 'rho' is used in a non-connect context. Notification: Performance of NFTyping.typeBindings: time 0.09543/3.372, allocations: 19.96 MB / 3.365 GB, free: 9.918 MB / 1.405 GB Warning: Allowing usage of enumeration expression: CHP.typeOfResource as Integer: CAST(Integer, CHP.typeOfResource). This is non-standard Modelica, use Integer(CHP.typeOfResource) instead! Warning: Allowing usage of enumeration expression: CHP.typeOfPrimaryEnergyCarrier as Integer: CAST(Integer, CHP.typeOfPrimaryEnergyCarrier). This is non-standard Modelica, use Integer(CHP.typeOfPrimaryEnergyCarrier) instead! Warning: Allowing usage of enumeration expression: CHP.typeOfPrimaryEnergyCarrierHeat as Integer: CAST(Integer, CHP.typeOfPrimaryEnergyCarrierHeat). This is non-standard Modelica, use Integer(CHP.typeOfPrimaryEnergyCarrierHeat) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Conventional as Integer: 2. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Conventional) instead! Warning: Allowing usage of enumeration expression: gasBoiler.typeOfPrimaryEnergyCarrier as Integer: CAST(Integer, gasBoiler.typeOfPrimaryEnergyCarrier). This is non-standard Modelica, use Integer(gasBoiler.typeOfPrimaryEnergyCarrier) instead! [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Basics/Functions/GasProperties/verboseXi.mo:2:1-93:14:writable] Warning: Pure function 'TransiEnt.Basics.Functions.GasProperties.verboseXi' contains a call to impure function 'Modelica.Utilities.Streams.print'. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Basics/Media/RealGasNCV_xi.mo:57:3-62:9:writable] Warning: In relation gasBoiler.vleNCVSensor.realGasNCV_InToOut.NCVIn <> 0.0, <> on Real numbers is only allowed inside functions. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Basics/Media/RealGasNCV_xi.mo:57:3-62:9:writable] Warning: In relation gasBoiler.vleNCVSensor.realGasNCV_OutToIn.NCVIn <> 0.0, <> on Real numbers is only allowed inside functions. Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Consumer as Integer: 1. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Consumer) instead! Warning: Allowing usage of enumeration expression: UCTE.LumpedGrid.PowerPlants.typeOfBalancingPowerResource as Integer: CAST(Integer, UCTE.LumpedGrid.PowerPlants.typeOfBalancingPowerResource). This is non-standard Modelica, use Integer(UCTE.LumpedGrid.PowerPlants.typeOfBalancingPowerResource) instead! Warning: Allowing usage of enumeration expression: UCTE.LumpedGrid.PowerPlants.typeOfPrimaryEnergyCarrier as Integer: CAST(Integer, UCTE.LumpedGrid.PowerPlants.typeOfPrimaryEnergyCarrier). This is non-standard Modelica, use Integer(UCTE.LumpedGrid.PowerPlants.typeOfPrimaryEnergyCarrier) instead! Warning: Allowing usage of enumeration expression: UCTE.LumpedGrid.PowerPlants.typeOfResource as Integer: CAST(Integer, UCTE.LumpedGrid.PowerPlants.typeOfResource). This is non-standard Modelica, use Integer(UCTE.LumpedGrid.PowerPlants.typeOfResource) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Consumer as Integer: 1. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Consumer) instead! Warning: Allowing usage of enumeration expression: electricGrid_SubSystem.windProduction.typeOfPrimaryEnergyCarrier as Integer: CAST(Integer, electricGrid_SubSystem.windProduction.typeOfPrimaryEnergyCarrier). This is non-standard Modelica, use Integer(electricGrid_SubSystem.windProduction.typeOfPrimaryEnergyCarrier) instead! Warning: Allowing usage of enumeration expression: electricGrid_SubSystem.windProduction.typeOfResource as Integer: CAST(Integer, electricGrid_SubSystem.windProduction.typeOfResource). This is non-standard Modelica, use Integer(electricGrid_SubSystem.windProduction.typeOfResource) instead! Warning: Allowing usage of enumeration expression: electricGrid_SubSystem.pVPlant.typeOfPrimaryEnergyCarrier as Integer: CAST(Integer, electricGrid_SubSystem.pVPlant.typeOfPrimaryEnergyCarrier). This is non-standard Modelica, use Integer(electricGrid_SubSystem.pVPlant.typeOfPrimaryEnergyCarrier) instead! Warning: Allowing usage of enumeration expression: electricGrid_SubSystem.pVPlant.typeOfResource as Integer: CAST(Integer, electricGrid_SubSystem.pVPlant.typeOfResource). This is non-standard Modelica, use Integer(electricGrid_SubSystem.pVPlant.typeOfResource) instead! Warning: Allowing usage of enumeration expression: gasGrid_subSystem.feedInStation1.electrolyzer.typeOfResource as Integer: CAST(Integer, gasGrid_subSystem.feedInStation1.electrolyzer.typeOfResource). This is non-standard Modelica, use Integer(gasGrid_subSystem.feedInStation1.electrolyzer.typeOfResource) instead! Warning: Allowing usage of enumeration expression: gasGrid_subSystem.feedInStation2.electrolyzer.typeOfResource as Integer: CAST(Integer, gasGrid_subSystem.feedInStation2.electrolyzer.typeOfResource). This is non-standard Modelica, use Integer(gasGrid_subSystem.feedInStation2.electrolyzer.typeOfResource) instead! Notification: Performance of NFTyping.typeClassSections: time 0.07056/3.443, allocations: 24.33 MB / 3.389 GB, free: 11.58 MB / 1.42 GB Notification: Performance of NFFlatten.flatten: time 0.1346/3.578, allocations: 76.63 MB / 3.464 GB, free: 0.9727 MB / 1.452 GB Notification: Performance of NFFlatten.resolveConnections: time 0.08599/3.664, allocations: 41.28 MB / 3.504 GB, free: 2.012 MB / 1.483 GB Notification: Performance of NFEvalConstants.evaluate: time 0.0852/3.749, allocations: 31.83 MB / 3.535 GB, free: 3.375 MB / 1.514 GB Notification: Performance of NFSimplifyModel.simplify: time 0.07706/3.826, allocations: 40.78 MB / 3.575 GB, free: 12.11 MB / 1.561 GB Notification: Performance of NFPackage.collectConstants: time 0.04193/3.868, allocations: 10.43 MB / 3.585 GB, free: 1.68 MB / 1.561 GB Notification: Performance of NFFlatten.collectFunctions: time 0.05881/3.927, allocations: 12.52 MB / 3.597 GB, free: 5.297 MB / 1.577 GB Notification: Performance of NFScalarize.scalarize: time 0.06544/3.992, allocations: 36.6 MB / 3.633 GB, free: 0.9766 MB / 1.608 GB Notification: Performance of NFVerifyModel.verify: time 0.1457/4.138, allocations: 47.82 MB / 3.68 GB, free: 1.23 MB / 1.655 GB Notification: Performance of NFConvertDAE.convert: time 0.245/4.383, allocations: 154.8 MB / 3.831 GB, free: 8.898 MB / 1.811 GB Notification: Performance of FrontEnd - DAE generated: time 8.626e-06/4.383, allocations: 0 / 3.831 GB, free: 8.898 MB / 1.811 GB Notification: Performance of FrontEnd: time 2.555e-06/4.383, allocations: 4 kB / 3.831 GB, free: 8.895 MB / 1.811 GB Notification: Performance of Transformations before backend: time 0.004848/4.388, allocations: 0 / 3.831 GB, free: 8.895 MB / 1.811 GB Error: Too many equations, over-determined system. The model has 12400 equation(s) and 12392 variable(s). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Basics/Interfaces/Thermal/FluidPort.mo:45:3-45:107:writable] Warning: Equation 1034 (size: 1) DHN_source.fluidPortOut.m_flow + CHP.inlet.m_flow = 0.0 is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: CHP.inlet.m_flow, DHN_source.fluidPortOut.m_flow Equations used to solve those variables: Equation 762 (size: 1): DHN_source.boundaryConditions.steam_a.m_flow - DHN_source.fluidPortOut.m_flow = 0.0 Equation 880 (size: 1): CHP.HX.inlet.m_flow + CHP.T_in_sensor.port.m_flow - CHP.inlet.m_flow = 0.0 [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Producer/Combined/LargeScaleCHP/Base/PartialCHP.mo:340:3-341:127:writable] Warning: Equation 82 (size: 1) CHP.inlet.p = CHP.HX.inlet.p is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: CHP.inlet.p, CHP.HX.inlet.p Equations used to solve those variables: Equation 81 (size: 1): CHP.inlet.p = CHP.T_in_sensor.port.p Equation 1450 (size: 1): CHP.HX.inlet.p = CHP.HX.p + CHP.HX.pressureLoss.Delta_p + CHP.HX.phaseBorder.Delta_p_geo_in [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Boundaries/FluidFlow/BoundaryVLE_Txim_flow.mo:140:3-143:22:writable] Warning: Equation 761 (size: 1) DHN_source.fluidPortOut.p = DHN_source.boundaryConditions.steam_a.p is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: DHN_source.boundaryConditions.steam_a.p, DHN_source.fluidPortOut.p Equations used to solve those variables: Equation 804 (size: 1): DHN_source.fluidPortOut.p = CHP.inlet.p Equation 7480 (size: 1): DHN_source.boundaryConditions.fluidOut.p = DHN_source.boundaryConditions.steam_a.p