ThermoPower test using OpenModelica

Total Frontend Backend SimCode Templates Compilation Simulation Verification
108 101 101 101 101 99 89 0

Test started: 2024-06-29 05:26:27
Total time taken: 0:37:41
System info: AMD Ryzen 9 5950X 16-Core Processor, 63 GB RAM, Ubuntu 22.04.3 LTS

OpenModelica Version: OMCompiler v1.22.4

OpenModelicaLibraryTesting Changes

CommitDateAuthorSummary
b3682912024-06-20 15:15:32 +0200Adrian Popadd MSL maint/4.1.x via 4.1.0-beta.om (#115)

Tested Library: ThermoPower 3.1

{
 "path": "ThermoPower",
 "sha": "e2b011ac7fd90f9cf5771f29f1aefa160550b6ee",
 "support": "experimental",
 "uses": {
  "Modelica": "3.2.3"
 },
 "version": "3.1.0-master",
 "zipfile": "https://github.com/casella/ThermoPower/archive/e2b011ac7fd90f9cf5771f29f1aefa160550b6ee.zip"
}

BuildModel time limit: 660s
Simulation time limit: 480s
Default tolerance: 1e-06
Optimization level: -Os -march=native

Flags:
setCommandLineOptions("--simCodeTarget=Cpp")
setCommandLineOptions("-d=nogen");
setCommandLineOptions("-d=initialization");
setCommandLineOptions("-d=backenddaeinfo");
setCommandLineOptions("-d=discreteinfo");
setCommandLineOptions("-d=stateselection");
setCommandLineOptions("-d=execstat");
setMatchingAlgorithm("PFPlusExt");
setIndexReductionMethod("dynamicStateSelection");
Config:
{
 "library": "ThermoPower",
 "optlevel": "-Os -march=native"
}

Links are provided if getErrorString() or the simulation generates output. The links are coded with red if there were errors, yellow if there were warnings, and normal links if there are only notifications.

ModelVerifiedSimulateTotal buildModelParsingFrontendBackendSimCodeTemplatesCompileTotal Execution
ThermoPower.Examples.BraytonCycle.ClosedLoopSimulator (sim) 0.2016.553.571.140.500.040.1314.7320.95
ThermoPower.Examples.BraytonCycle.OpenLoopSimulator (sim) 0.1516.243.571.080.520.040.1314.4720.53
ThermoPower.Examples.CISE.Simulators.CISESim2States120501 (sim) 0.1619.963.780.853.140.150.5215.3024.49
ThermoPower.Examples.CISE.Simulators.CISESim120501 (sim) 0.4933.802.861.205.310.320.8626.1137.68
ThermoPower.Examples.CISE.Simulators.CISESim180503 (sim) 0.6133.833.691.425.050.321.0026.0338.62
ThermoPower.Examples.CISE.Simulators.CISESim180504 (sim) 0.5333.753.611.165.220.300.9326.1438.55
ThermoPower.Examples.HRB.Simulators.ClosedLoopDigitalSimulator (sim) 1.1926.283.621.772.030.190.7621.5231.71
ThermoPower.Examples.HRB.Simulators.ClosedLoopDigitalSimulatorSimplified (sim) 0.1019.163.811.621.200.110.6015.6323.64
ThermoPower.Examples.HRB.Simulators.ClosedLoopSimulator (sim) 1.3024.903.791.652.030.180.7420.3030.51
ThermoPower.Examples.HRB.Simulators.OpenLoopSimulator (sim) 0.4930.953.571.751.950.201.2125.8435.69
ThermoPower.Examples.HRB.Simulators.OpenLoopSimulatorHtc 0.006.613.721.711.660.550.771.9210.94
ThermoPower.Examples.HRB.Simulators.OpenLoopSimulatorSS (sim) 0.3624.623.651.712.020.180.7719.9429.22
ThermoPower.Examples.HRB.Simulators.OpenLoopSimulatorSimplified (sim) 0.0919.533.701.841.110.120.6115.8523.95
ThermoPower.Examples.HRB.Simulators.TestPI (sim) 0.045.093.540.160.020.010.054.869.30
ThermoPower.Examples.RankineCycle.Simulators.ClosedLoop (sim) 5.8239.313.531.975.640.591.3429.7749.32
ThermoPower.PowerPlants.ElectricGeneratorGroup.Tests.Test_Generator_SE 0.000.162.200.160.000.000.000.002.95
ThermoPower.PowerPlants.ElectricGeneratorGroup.Tests.Test_Generator_SE_breaker 0.000.182.320.180.000.000.000.003.07
ThermoPower.PowerPlants.ElectricGeneratorGroup.Tests.Test_Generator_SE_com 0.000.152.160.150.000.000.000.002.88
ThermoPower.PowerPlants.Simulators.CCPP_Sim3 0.002.252.382.250.000.000.000.005.32
ThermoPower.PowerPlants.Simulators.SteamPlant_Sim1 0.003.032.343.030.000.000.000.005.98
ThermoPower.PowerPlants.Simulators.SteamPlant_Sim1_dp 0.002.232.382.230.000.000.000.005.21
ThermoPower.PowerPlants.Simulators.SteamPlant_Sim2 0.002.982.342.980.000.000.000.005.92
ThermoPower.PowerPlants.SteamTurbineGroup.Tests.TestST3LRh_base (sim) 0.029.832.440.610.200.020.288.7212.89
ThermoPower.PowerPlants.SteamTurbineGroup.Tests.TestST3LRh_bypass (sim) 0.0712.292.170.620.450.030.0811.1215.11
ThermoPower.PowerPlants.SteamTurbineGroup.Tests.TestST3LRh_valve (sim) 0.1110.862.390.580.270.190.089.7414.00
ThermoPower.PowerPlants.SteamTurbineGroup.Tests.TestSTG_cc (sim) 0.6213.412.220.680.480.020.1012.1316.86
ThermoPower.PowerPlants.SteamTurbineGroup.Tests.TestTurbineHPefficiency 0.002.823.540.390.510.020.101.806.98
ThermoPower.Test.DistributedParameterComponents.CheckFlow1DFV2phMassBalance (sim) 2.357.452.240.190.480.030.066.7012.55
ThermoPower.Test.DistributedParameterComponents.TestConstantHeatTransferTwoGrid_Fcoarse (sim) 0.016.262.190.160.060.010.045.999.01
ThermoPower.Test.DistributedParameterComponents.TestConstantHeatTransferTwoGrid_Wcoarse (sim) 0.026.792.370.150.070.140.046.399.71
ThermoPower.Test.DistributedParameterComponents.TestFlow1D2phChen (sim) 7.9218.602.180.422.600.160.3215.1029.23
ThermoPower.Test.DistributedParameterComponents.TestFlow1D2phChen_hf (sim) 30.7417.372.140.484.100.180.3012.3150.77
ThermoPower.Test.DistributedParameterComponents.TestFlow1D2phDB (sim) 0.5318.262.300.442.340.150.3415.0021.58
ThermoPower.Test.DistributedParameterComponents.TestFlow1D2phDB_hf (sim) 3.6115.932.220.433.530.190.3011.4822.29
ThermoPower.Test.DistributedParameterComponents.TestFlow1Dfem2ph (sim) 0.7625.882.180.497.151.530.4616.2529.37
ThermoPower.Test.DistributedParameterComponents.TestFlowDependentHeatTransferCoefficient2ph (sim) 0.027.572.450.170.490.040.066.7910.55
ThermoPower.Test.DistributedParameterComponents.TestGasFlow1DFV_A (sim) 0.049.742.340.630.460.030.068.5512.70
ThermoPower.Test.DistributedParameterComponents.TestGasFlow1DFV_B (sim) 0.0510.782.370.660.760.060.099.2113.70
ThermoPower.Test.DistributedParameterComponents.TestGasFlow1DFV_C (sim) 0.0911.302.270.670.740.060.089.7514.37
ThermoPower.Test.DistributedParameterComponents.TestHeatTransfer2phDB (sim) 0.028.092.160.200.490.050.087.2810.78
ThermoPower.Test.DistributedParameterComponents.TestRefrigerantEvaporator (sim) 38.3230.402.181.023.570.400.5624.8571.39
ThermoPower.Test.DistributedParameterComponents.TestWalls (sim) 0.015.122.180.130.010.010.024.957.80
ThermoPower.Test.DistributedParameterComponents.TestWaterFlow1DFEM_A (sim) 0.2813.342.340.461.460.090.3610.9716.51
ThermoPower.Test.DistributedParameterComponents.TestWaterFlow1DFEM_B (sim) 0.2713.382.270.461.540.110.4210.8716.56
ThermoPower.Test.DistributedParameterComponents.TestWaterFlow1DFEM_C (sim) 0.2913.182.200.461.520.090.1510.9716.29
ThermoPower.Test.DistributedParameterComponents.TestWaterFlow1DFEM_D (sim) 0.1512.342.250.441.460.080.1510.2315.30
ThermoPower.Test.DistributedParameterComponents.TestWaterFlow1DFEM_E (sim) 0.5619.362.340.592.800.160.4515.3622.76
ThermoPower.Test.DistributedParameterComponents.TestWaterFlow1DFEM_F (sim) 0.9935.862.280.624.610.581.8628.1939.70
ThermoPower.Test.DistributedParameterComponents.TestWaterFlow1DFEM_G (sim) 482.0310.552.290.220.930.030.079.30495.41
ThermoPower.Test.DistributedParameterComponents.TestWaterFlow1DFEM_J (sim) 0.2412.252.290.221.260.260.1310.3815.39
ThermoPower.Test.DistributedParameterComponents.TestWaterFlow1DFEM_K (sim) 0.2212.512.280.241.350.270.1210.5315.56
ThermoPower.Test.DistributedParameterComponents.TestWaterFlow1DFV2ph (sim) 0.8926.612.190.555.650.410.4919.5130.21
ThermoPower.Test.DistributedParameterComponents.TestWaterFlow1DFV2ph_A (sim) 0.2614.372.220.482.030.320.1011.4517.37
ThermoPower.Test.DistributedParameterComponents.TestWaterFlow1DFV2ph_B (sim) 0.2613.512.210.451.970.320.0910.6916.47
ThermoPower.Test.DistributedParameterComponents.TestWaterFlow1DFV2ph_C (sim) 1.7327.592.190.535.460.460.7320.4132.02
ThermoPower.Test.DistributedParameterComponents.TestWaterFlow1DFV2ph_D (sim) 0.2613.982.180.411.970.320.1111.1717.00
ThermoPower.Test.DistributedParameterComponents.TestWaterFlow1DFV_A (sim) 0.3712.092.190.420.820.070.2310.5515.23
ThermoPower.Test.DistributedParameterComponents.TestWaterFlow1DFV_A_Fast (sim) 0.1110.652.360.530.280.060.329.4613.66
ThermoPower.Test.DistributedParameterComponents.TestWaterFlow1DFV_AdaptiveAverageTemp (sim) 0.078.892.280.460.280.020.078.0711.77
ThermoPower.Test.DistributedParameterComponents.TestWaterFlow1DFV_B (sim) 0.1610.492.320.420.630.040.079.3313.69
ThermoPower.Test.DistributedParameterComponents.TestWaterFlow1DFV_D (sim) 0.059.642.070.210.410.020.078.9312.38
ThermoPower.Test.DistributedParameterComponents.TestWaterFlow1DFV_DB (sim) 0.2411.232.350.510.840.060.089.7414.47
ThermoPower.Test.DistributedParameterComponents.TestWaterFlow1DFV_E (sim) 0.8722.682.090.532.130.200.5819.2426.30
ThermoPower.Test.DistributedParameterComponents.TestWaterFlow1DFV_F (sim) 0.9428.902.210.622.180.201.1624.7432.63
ThermoPower.Test.ElectricalComponents.TestElectrical1 (sim) 0.014.602.080.100.010.000.024.477.19
ThermoPower.Test.ElectricalComponents.TestElectrical2 (sim) 0.014.452.210.140.010.010.024.277.15
ThermoPower.Test.ElectricalComponents.TestElectrical3 (sim) 0.024.512.220.110.010.010.024.367.27
ThermoPower.Test.ElectricalComponents.TestElectrical4 (sim) 0.024.602.250.100.010.010.024.467.38
ThermoPower.Test.ElectricalComponents.TestElectrical5 (sim) 0.025.002.240.160.030.010.034.787.79
ThermoPower.Test.ElectricalComponents.TestElectrical6 (sim) 0.024.952.220.100.020.010.024.797.70
ThermoPower.Test.ElectricalComponents.TestElectrical7 (sim) 0.024.952.160.090.020.010.024.817.63
ThermoPower.Test.GasComponents.TestCC (sim) 0.1810.862.120.630.090.020.279.8613.78
ThermoPower.Test.GasComponents.TestCompressorConstSpeed (sim) 0.027.852.310.630.030.010.057.1210.76
ThermoPower.Test.GasComponents.TestCompressorInertia (sim) 0.038.322.350.590.030.010.067.6311.29
ThermoPower.Test.GasComponents.TestFanMech (sim) 0.488.182.250.480.060.010.047.5911.53
ThermoPower.Test.GasComponents.TestGT (sim) 0.039.832.310.520.050.020.079.1712.78
ThermoPower.Test.GasComponents.TestGT_ISO (sim) 0.039.602.330.600.060.120.068.7612.52
ThermoPower.Test.GasComponents.TestGasMixer (sim) 0.068.432.170.520.080.020.047.7711.29
ThermoPower.Test.GasComponents.TestGasTurbine (sim) 0.028.062.520.570.030.010.047.4111.16
ThermoPower.Test.GasComponents.TestGasTurbineStodola (sim) 0.027.542.330.590.030.010.046.8810.50
ThermoPower.Test.GasComponents.TestGasValve (sim) 0.0313.902.260.710.380.020.0912.7016.74
ThermoPower.Test.GasComponents.TestGasValveOpPoint (sim) 0.0212.802.150.660.120.020.3111.6915.50
ThermoPower.Test.GasComponents.TestTurboJetConstSpeed (sim) 0.2214.302.340.670.350.030.0813.1817.42
ThermoPower.Test.GasComponents.TestTurboJetInertia (sim) 0.2514.492.330.740.360.030.0913.2717.74
ThermoPower.Test.WaterComponents.TestAccumulator (sim) 0.037.692.470.190.330.010.047.1010.71
ThermoPower.Test.WaterComponents.TestBarometricCondenser (sim) 0.088.382.440.230.300.010.057.7811.59
ThermoPower.Test.WaterComponents.TestCoeffValve (sim) 0.028.722.300.540.100.020.068.0111.61
ThermoPower.Test.WaterComponents.TestCoolingTowerClosed (sim) 1.4612.682.330.600.690.060.2811.0417.03
ThermoPower.Test.WaterComponents.TestCoolingTowerPacking (sim) 0.2512.272.360.620.440.050.0911.0715.50
ThermoPower.Test.WaterComponents.TestCoolingTowerStatic (sim) 0.049.132.370.580.250.200.068.0312.16
ThermoPower.Test.WaterComponents.TestExpansionTankIdeal (sim) 0.058.952.290.210.380.020.078.2811.86
ThermoPower.Test.WaterComponents.TestJoin (sim) 0.027.592.170.460.110.020.056.9610.42
ThermoPower.Test.WaterComponents.TestJoinRev (sim) 0.028.282.320.560.130.020.067.5111.21
ThermoPower.Test.WaterComponents.TestMixer (sim) 0.038.592.380.470.140.020.057.9111.64
ThermoPower.Test.WaterComponents.TestMixerSlowFast (sim) 0.027.932.350.220.270.010.047.3910.85
ThermoPower.Test.WaterComponents.TestMixerSlowFastSteam (sim) 0.058.272.350.300.360.010.057.5511.25
ThermoPower.Test.WaterComponents.TestST1 (sim) 0.038.582.360.250.390.010.067.8811.53
ThermoPower.Test.WaterComponents.TestST2 (sim) 0.038.272.400.250.380.010.057.5911.41
ThermoPower.Test.WaterComponents.TestSources (sim) 0.028.562.420.780.020.010.327.4211.65
ThermoPower.Test.WaterComponents.TestSplitRev (sim) 0.028.122.260.590.140.020.067.3111.00
ThermoPower.Test.WaterComponents.TestTurbineStodolaPartialArc (sim) 0.017.872.460.350.310.010.047.1610.86
ThermoPower.Test.WaterComponents.TestValveChoked (sim) 0.027.162.340.230.330.010.046.5510.16
ThermoPower.Test.WaterComponents.TestValves (sim) 0.028.682.330.540.140.020.067.9211.55
ThermoPower.Test.WaterComponents.ValveZeroFlow (sim) 0.017.502.310.230.310.010.046.9110.39
ThermoPower.Test.WaterComponents.ValveZeroFlow2 (sim) 0.057.812.290.200.260.010.047.3110.80
ThermoPower.Test.WaterComponents.WaterPump (sim) 0.108.212.430.250.370.010.047.5411.30
ThermoPower.Test.WaterComponents.WaterPumpMech (sim) 0.108.232.400.210.330.010.047.6311.55
ThermoPower.Test.WaterComponents.WaterPumps (sim) 0.4110.192.420.550.130.020.079.4213.63