Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr Buildings_latest_Buildings.Fluid.Geothermal.ZonedBorefields.Validation.FEFLOW.InletTemperaturePulse.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.0.0-master/package.mo", uses=false) Using package Buildings with version 12.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.0.0-master/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Running command: translateModel(Buildings.Fluid.Geothermal.ZonedBorefields.Validation.FEFLOW.InletTemperaturePulse,tolerance=1e-06,outputFormat="mat",numberOfIntervals=5000,variableFilter="time|TBorFieIn.1..T|TBorFieOut.1..T|TOut.y.1.|TBorFieOut.2..T|TOut.y.2.",fileNamePrefix="Buildings_latest_Buildings.Fluid.Geothermal.ZonedBorefields.Validation.FEFLOW.InletTemperaturePulse") translateModel(Buildings.Fluid.Geothermal.ZonedBorefields.Validation.FEFLOW.InletTemperaturePulse,tolerance=1e-06,outputFormat="mat",numberOfIntervals=5000,variableFilter="time|TBorFieIn.1..T|TBorFieOut.1..T|TOut.y.1.|TBorFieOut.2..T|TOut.y.2.",fileNamePrefix="Buildings_latest_Buildings.Fluid.Geothermal.ZonedBorefields.Validation.FEFLOW.InletTemperaturePulse") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.001831/0.001831, allocations: 106.1 kB / 16.27 MB, free: 6.414 MB / 14.72 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001736/0.001736, allocations: 189.8 kB / 17.2 MB, free: 5.953 MB / 14.72 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.428/1.428, allocations: 222.9 MB / 240.9 MB, free: 15.23 MB / 206.1 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.0.0-master/package.mo): time 2.719/2.719, allocations: 482.4 MB / 0.7553 GB, free: 7.004 MB / 0.6231 GB Notification: Performance of FrontEnd - loaded program: time 0.001928/0.001928, allocations: 72.12 kB / 0.9245 GB, free: 8 kB / 0.6856 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.9969/0.9989, allocations: 162.2 MB / 1.083 GB, free: 1.672 MB / 0.8262 GB Notification: Performance of NFInst.instantiate(Buildings.Fluid.Geothermal.ZonedBorefields.Validation.FEFLOW.InletTemperaturePulse): time 0.1197/1.119, allocations: 97.89 MB / 1.179 GB, free: 8.559 MB / 0.9044 GB Notification: Performance of NFInst.instExpressions: time 0.05344/1.172, allocations: 32.29 MB / 1.21 GB, free: 12.46 MB / 0.9356 GB Notification: Performance of NFInst.updateImplicitVariability: time 0.008197/1.18, allocations: 139.2 kB / 1.21 GB, free: 12.32 MB / 0.9356 GB Notification: Performance of NFTyping.typeComponents: time 0.009/1.189, allocations: 2.652 MB / 1.213 GB, free: 9.66 MB / 0.9356 GB Notification: Performance of NFTyping.typeBindings: time 0.01734/1.207, allocations: 4.913 MB / 1.218 GB, free: 4.727 MB / 0.9356 GB Notification: Performance of NFTyping.typeClassSections: time 0.01535/1.222, allocations: 5.45 MB / 1.223 GB, free: 15.31 MB / 0.9512 GB [/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/Compiler/NFFrontEnd/NFExpression.mo:1588:7-1589:100:writable] Error: Internal error NFExpression.makeSubscriptedExp: too few dimensions in Buildings.Fluid.Geothermal.Borefields.Data.Configuration.Template(Buildings.Fluid.Geothermal.Borefields.Types.BoreholeConfiguration.DoubleUTubeParallel, false, 0.0, {0.2304597222222222, 0.2304597222222222}[], {5.531033333333334, 0.921838888888889}[], {34000.0, 34000.0}[], 85.0, 0.075, 0.5, {24, 4}[], {{3.0, 1.5}, {6.0, 1.5}, {9.0, 1.5}, {12.0, 1.5}, {1.5, 4.5}, {4.5, 4.5}, {7.5, 4.5}, {10.5, 4.5}, {3.0, 7.5}, {6.0, 7.5}, {9.0, 7.5}, {12.0, 7.5}, {1.5, 10.5}, {4.5, 10.5}, {7.5, 10.5}, {10.5, 10.5}, {3.0, 13.5}, {6.0, 13.5}, {9.0, 13.5}, {12.0, 13.5}, {1.5, 16.5}, {4.5, 16.5}, {7.5, 16.5}, {10.5, 16.5}, {5.4, 22.5}, {10.8, 22.5}, {2.7, 28.5}, {8.1, 28.5}}, 0.016, 0.42, 0.0029, 0.0282842712474619, {2.304597222222223e-05, 2.304597222222223e-05}[]) to apply subscripts [] [/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/Compiler/NFFrontEnd/NFCeval.mo:1731:9-1732:93:writable] Error: Internal error NFCeval.evalRelationEqual failed to evaluate ‘borFie.borHol.borFieDat.conDat.borCon == Buildings.Fluid.Geothermal.Borefields.Types.BoreholeConfiguration.DoubleUTubeParallel‘ [/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/Compiler/NFFrontEnd/NFCeval.mo:1494:9-1494:67:writable] Error: Internal error NFCeval.evalLogicBinaryAnd failed to evaluate ‘true and borFie.borHol.borFieDat.conDat.borCon == Buildings.Fluid.Geothermal.Borefields.Types.BoreholeConfiguration.DoubleUTubeParallel‘ Notification: Performance of FrontEnd: time 0.012/1.234, allocations: 7.26 MB / 1.23 GB, free: 8.039 MB / 0.9512 GB