Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr SiemensPower_SiemensPower.Components.SolidComponents.Tests.wall_test.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/SiemensPower 2.2.0/package.mo", uses=false) Using package SiemensPower with version 2.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/SiemensPower 2.2.0/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Running command: translateModel(SiemensPower.Components.SolidComponents.Tests.wall_test,tolerance=1e-06,outputFormat="empty",numberOfIntervals=1000,variableFilter="",fileNamePrefix="SiemensPower_SiemensPower.Components.SolidComponents.Tests.wall_test") translateModel(SiemensPower.Components.SolidComponents.Tests.wall_test,tolerance=1e-06,outputFormat="empty",numberOfIntervals=1000,variableFilter="",fileNamePrefix="SiemensPower_SiemensPower.Components.SolidComponents.Tests.wall_test") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.001319/0.001318, allocations: 115.3 kB / 15.34 MB, free: 0.5156 MB / 14.72 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.00169/0.00169, allocations: 191.8 kB / 16.25 MB, free: 6.629 MB / 14.72 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.737/1.737, allocations: 205.1 MB / 222.1 MB, free: 4.695 MB / 174.1 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/SiemensPower 2.2.0/package.mo): time 0.03262/0.03262, allocations: 5.565 MB / 275 MB, free: 15.87 MB / 238.1 MB Notification: Modelica requested package Complex of version 3.2.3. Complex 4.0.0 is used instead which states that it is fully compatible without conversion script needed. Notification: Modelica requested package ModelicaServices of version 3.2.3. ModelicaServices 4.0.0 is used instead which states that it is fully compatible without conversion script needed. Notification: SiemensPower requested package Modelica of version 3.2.1. Modelica 3.2.3 is used instead which states that it is fully compatible without conversion script needed. Notification: Performance of FrontEnd - loaded program: time 0.001402/0.001402, allocations: 67.89 kB / 333.7 MB, free: 29.22 MB / 254.1 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.09831/0.09972, allocations: 47.9 MB / 381.6 MB, free: 13.32 MB / 286.1 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/SiemensPower 2.2.0/Components/SolidComponents/Tests/wall_test.mo:6:5-7:32:writable] Error: Modified element considerAxialHeatTransfer not found in class Wall. Notification: Performance of FrontEnd: time 0.001803/0.1016, allocations: 475.8 kB / 382.1 MB, free: 12.85 MB / 286.1 MB