Environment - simulationEnvironment: startTime=0 stopTime=10 tolerance=1e-06 numberOfIntervals=50000 stepSize=0.0002 Regular simulation: ./Modelica_3.2.3_Modelica.Electrical.PowerConverters.Examples.ACDC.RectifierBridge2Pulse.ThyristorBridge2Pulse_RLV_Characteristic -abortSlowSimulation -alarm=480 -emit_protected -lv LOG_STATS LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.00338276s reading init.xml | | | | | | 0.000315672s reading info.xml | | | | | | 0.000699091s [ 0.0%] pre-initialization | | | | | | 0.000164128s [ 0.0%] initialization | | | | | | 6.4741e-05s [ 0.0%] steps | | | | | | 0.110698s [ 6.8%] solver (excl. callbacks) | | | | | | 0.0340311s [ 2.1%] creating output-file | | | | | | 0.733707s [ 45.4%] event-handling | | | | | | 0.0286431s [ 1.8%] overhead | | | | | | 0.709598s [ 43.9%] simulation | | | | | | 1.61761s [100.0%] total | | | | | events | | | | | | 2998 state events | | | | | | 1000 time events | | | | | solver: dassl | | | | | | 125952 steps taken | | | | | | 156578 calls of functionODE | | | | | | 40004 evaluations of jacobian | | | | | | 2320 error test failures | | | | | | 0 convergence test failures | | | | | | 0.0926361s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.