Environment - simulationEnvironment: startTime=432000 stopTime=864000 tolerance=1e-07 numberOfIntervals=2500 stepSize=172.8 Regular simulation: ./Buildings_latest_Buildings.ThermalZones.EnergyPlus_9_6_0.Examples.SmallOffice.Guideline36Winter -abortSlowSimulation -alarm=480 -emit_protected -lv LOG_STATS EnergyPlus Starting EnergyPlus, Version 9.6.0-316f894e91, YMD=2024.05.19 02:04 Adjusting Air System Sizing Adjusting Standard 62.1 Ventilation Sizing Initializing Simulation Reporting Surfaces Beginning Primary Simulation Initializing New Environment Parameters Warming up {1} Warming up {2} Warming up {3} Warming up {4} Warming up {5} Warming up {6} Warming up {7} Warming up {8} Warming up {9} Warming up {10} Warming up {11} Starting Simulation at 01/01/2017 for SPAWN-RUNPERIOD LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. assert | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.0.0-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:99:3-99:89:writable] | | | | The following assertion has been violated at time 432000.000002 | | | | ((hvac.fanSup.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= hvac.fanSup.etaHyd, has value: -1.06684e-13" assert | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.0.0-master/Fluid/Movers/BaseClasses/PowerInterface.mo:46:3-47:27:writable] | | | | The following assertion has been violated at time 432000.000002 | | | | ((hvac.fanSup.heaDis.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= hvac.fanSup.heaDis.etaHyd, has value: -2.62994e-09" assert | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.0.0-master/Controls/OBC/CDL/Utilities/Assert.mo:11:3-14:28:writable] | | | | The following assertion has been violated at time 453900.000009 | | | | ((hvac.conVAV[5].ala.not1.y)) --> "Warning: airflow is less than 50% of the setpoint." assert | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.0.0-master/Controls/OBC/CDL/Utilities/Assert.mo:11:3-14:28:writable] | | | | The following assertion has been violated at time 453900.000009 | | | | ((hvac.conVAV[5].ala.not2.y)) --> "Warning: airflow is less than 70% of the setpoint." assert | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.0.0-master/Fluid/Movers/BaseClasses/FlowMachineInterface.mo:311:3-315:28:writable] | | | | The following assertion has been violated at time 500587.904117 | | | | ((hvac.fanSup.eff.yMot >= 0.0)) --> "Variable violating min constraint: 0.0 <= hvac.fanSup.eff.yMot, has value: -1.16271e-55" assert | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.0.0-master/Fluid/Sensors/VolumeFlowRate.mo:19:3-25:24:writable] | | | | The following assertion has been violated at time 501120.000000 | | | | ((hvac.VOut1.V_flow >= 0.0)) --> "Variable violating min constraint: 0.0 <= hvac.VOut1.V_flow, has value: -7.09993e-19" assert | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.0.0-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:99:3-99:89:writable] | | | | The following assertion has been violated at time 504403.200000 | | | | ((hvac.pumHeaCoi.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= hvac.pumHeaCoi.etaHyd, has value: -1.05339e-26" assert | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.0.0-master/Fluid/Movers/BaseClasses/PowerInterface.mo:46:3-47:27:writable] | | | | The following assertion has been violated at time 504403.200000 | | | | ((hvac.pumHeaCoi.heaDis.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= hvac.pumHeaCoi.heaDis.etaHyd, has value: -9.36678e-26" assert | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.0.0-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:115:3-116:81:writable] | | | | The following assertion has been violated at time 504480.000000 | | | | ((hvac.pumHeaCoi.m_flow >= 0.0 and hvac.pumHeaCoi.m_flow <= 100000.0)) --> "Variable violating min/max constraint: 0.0 <= hvac.pumHeaCoi.m_flow <= 100000.0, has value: -2.30846e-14" assert | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.0.0-master/Fluid/Movers/BaseClasses/FlowMachineInterface.mo:311:3-315:28:writable] | | | | The following assertion has been violated at time 504480.000000 | | | | ((hvac.pumHeaCoi.eff.yMot >= 0.0)) --> "Variable violating min constraint: 0.0 <= hvac.pumHeaCoi.eff.yMot, has value: -1.65244e-34" Updating Shadowing Calculations, Start Date=01/08/2017 Continuing Simulation at 01/08/2017 for SPAWN-RUNPERIOD assert | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.0.0-master/Fluid/Movers/BaseClasses/FlowMachineInterface.mo:311:3-315:28:writable] | | | | The following assertion has been violated at time 759720.000000 | | | | ((hvac.pumCooCoi.eff.yMot >= 0.0)) --> "Variable violating min constraint: 0.0 <= hvac.pumCooCoi.eff.yMot, has value: -3.08166e-99" LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.291902s reading init.xml | | | | | | 0.0245218s reading info.xml | | | | | | 0.00476838s [ 0.0%] pre-initialization | | | | | | 7.70633s [ 3.2%] initialization | | | | | | 0.00536133s [ 0.0%] steps | | | | | | 7.03559s [ 2.9%] solver (excl. callbacks) | | | | | | 1.15851s [ 0.5%] creating output-file | | | | | | 25.1673s [ 10.4%] event-handling | | | | | | 0.271322s [ 0.1%] overhead | | | | | | 200.237s [ 82.9%] simulation | | | | | | 241.587s [100.0%] total | | | | | events | | | | | | 3536 state events | | | | | | 3601 time events | | | | | solver: dassl | | | | | | 135361 steps taken | | | | | | 177766 calls of functionODE | | | | | | 79198 evaluations of jacobian | | | | | | 2432 error test failures | | | | | | 117 convergence test failures | | | | | | 188.084s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully. Writing final SQL reports EnergyPlus Run Time=00hr 03min 54.44sec EnergyPlus Completed Successfully.