Environment - simulationEnvironment: startTime=0 stopTime=3600 tolerance=1e-06 numberOfIntervals=2500 stepSize=1.44 Regular simulation: ./Buildings_9_Buildings.ThermalZones.EnergyPlus_9_6_0.BaseClasses.Validation.FMUZoneAdapterZones2 -abortSlowSimulation -alarm=480 -lv LOG_STATS stdout | info | 0.000 FMUZoneAdapterZones2.building: Using pre-compiled FMU /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.3-maint.9.1.x/Resources/src/ThermalZones/EnergyPlus_9_6_0/FMUs/Zones3.fmu stdout | info | 0.000 FMUZoneAdapterZones2.building: Warning: Variable South_ZN_mSenFac does not specify units in /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_9_Buildings.ThermalZones.EnergyPlus_9_6_0.BaseClasses.Validation.FMUZoneAdapterZones2/spawn-FMUZoneAdapterZones2/EnergyPlus.fmu. It will not be converted to SI units. stdout | info | 0.000 FMUZoneAdapterZones2.building: Warning: Variable Core_ZN_mSenFac does not specify units in /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_9_Buildings.ThermalZones.EnergyPlus_9_6_0.BaseClasses.Validation.FMUZoneAdapterZones2/spawn-FMUZoneAdapterZones2/EnergyPlus.fmu. It will not be converted to SI units. stdout | info | 0.000 FMUZoneAdapterZones2.building: Warning from EnergyPlus: "*** Test warning written by Zones3.core.&##10;" stdout | info | 0.000 FMUZoneAdapterZones2.building: Warning from EnergyPlus: "*** Test warning written by Zones3.north.&##10;" stdout | info | 0.000 FMUZoneAdapterZones2.building: Warning from EnergyPlus: "*** Test warning written by Zones3.south.&##10;" LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0054661s reading init.xml | | | | | | 0.000798176s reading info.xml | | | | | | 0.000172734s [ 0.2%] pre-initialization | | | | | | 0.0702026s [ 80.9%] initialization | | | | | | 2.154e-06s [ 0.0%] steps | | | | | | 0.00115787s [ 1.3%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 0.00273741s [ 3.2%] event-handling | | | | | | 0.00327612s [ 3.8%] overhead | | | | | | 0.00925084s [ 10.7%] simulation | | | | | | 0.0867998s [100.0%] total | | | | | events | | | | | | 59 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 1040 steps taken | | | | | | 1040 calls of functionODE | | | | | | 980 evaluations of jacobian | | | | | | 0 error test failures | | | | | | 0 convergence test failures | | | | | | 0.000186175s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.