Environment - simulationEnvironment: startTime=0 stopTime=1 tolerance=1e-06 numberOfIntervals=2500 stepSize=0.0004 Regular simulation: ./Buildings_9_Buildings.Fluid.Movers.Validation.FlowControlled_m_flow -abortSlowSimulation -alarm=480 -emit_protected -lv LOG_STATS assert | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.3-maint.9.1.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:348:3-357:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((floMacSta.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning." assert | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.3-maint.9.1.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:348:3-357:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((floMacDyn.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning." LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0102585s reading init.xml | | | | | | 0.00110429s reading info.xml | | | | | | 0.000405441s [ 2.0%] pre-initialization | | | | | | 0.000285916s [ 1.4%] initialization | | | | | | 2.024e-06s [ 0.0%] steps | | | | | | 0.000786852s [ 3.9%] solver (excl. callbacks) | | | | | | 0.00117674s [ 5.9%] creating output-file | | | | | | 0.000272154s [ 1.4%] event-handling | | | | | | 0.00366212s [ 18.3%] overhead | | | | | | 0.0133659s [ 67.0%] simulation | | | | | | 0.0199572s [100.0%] total | | | | | events | | | | | | 2 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 115 steps taken | | | | | | 169 calls of functionODE | | | | | | 59 evaluations of jacobian | | | | | | 3 error test failures | | | | | | 1 convergence test failures | | | | | | 0.000143764s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.