Environment - simulationEnvironment: startTime=0 stopTime=86400 tolerance=1e-06 numberOfIntervals=2500 stepSize=34.56 Regular simulation: ./Buildings_8_Buildings.ThermalZones.EnergyPlus.Validation.ThermalZone.Infiltration -abortSlowSimulation -alarm=480 -lv LOG_STATS EnergyPlus Starting EnergyPlus, Version 9.5.0-e579c2aa82 (No OpenGL), YMD=2023.10.20 11:02 Adjusting Air System Sizing Adjusting Standard 62.1 Ventilation Sizing Initializing Simulation Reporting Surfaces Beginning Primary Simulation Initializing New Environment Parameters Warming up {1} Warming up {2} Warming up {3} Warming up {4} Warming up {5} Warming up {6} Warming up {7} Warming up {8} Starting Simulation at 01/01/2017 for SPAWN-RUNPERIOD stdout | info | 0.000 Infiltration.defInf.building: Warning from EnergyPlus: GetInternalHeatGains: People="SPAWN-ZONE-LIVING ZONE-RADIANTGAINS", Activity Level Schedule Name values stdout | info | 0.000 Infiltration.defInf.building: Warning from EnergyPlus: fall outside typical range [70,1000] W/person for Thermal Comfort Reporting. stdout | info | 0.000 Infiltration.defInf.building: Warning from EnergyPlus: Odd comfort values may result; Schedule="SPAWN-PEOPLEACTIVITY-SCHEDULE". stdout | info | 0.000 Infiltration.defInf.building: Warning from EnergyPlus: Entered min/max range=[1.0,] W/person.1.0 EnergyPlus Starting EnergyPlus, Version 9.5.0-e579c2aa82 (No OpenGL), YMD=2023.10.20 11:02 Adjusting Air System Sizing Adjusting Standard 62.1 Ventilation Sizing Initializing Simulation Reporting Surfaces Beginning Primary Simulation Initializing New Environment Parameters Warming up {1} Warming up {2} Warming up {3} Warming up {4} Warming up {5} Warming up {6} Warming up {7} Warming up {8} Starting Simulation at 01/01/2017 for SPAWN-RUNPERIOD stdout | info | 0.000 Infiltration.higInf.building: Warning from EnergyPlus: GetInternalHeatGains: People="SPAWN-ZONE-LIVING ZONE-RADIANTGAINS", Activity Level Schedule Name values stdout | info | 0.000 Infiltration.higInf.building: Warning from EnergyPlus: fall outside typical range [70,1000] W/person for Thermal Comfort Reporting. stdout | info | 0.000 Infiltration.higInf.building: Warning from EnergyPlus: Odd comfort values may result; Schedule="SPAWN-PEOPLEACTIVITY-SCHEDULE". stdout | info | 0.000 Infiltration.higInf.building: Warning from EnergyPlus: Entered min/max range=[1.0,] W/person.1.0 assert | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/Fluid/Interfaces/PartialTwoPortInterface.mo:21:3-22:81:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((defInf.duc.m_flow >= 0.0 and defInf.duc.m_flow <= 100000.0)) --> "Variable violating min/max constraint: 0.0 <= defInf.duc.m_flow <= 100000.0, has value: -2.63739e-14" assert | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/Fluid/Interfaces/PartialTwoPortInterface.mo:21:3-22:81:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((higInf.duc.m_flow >= 0.0 and higInf.duc.m_flow <= 100000.0)) --> "Variable violating min/max constraint: 0.0 <= higInf.duc.m_flow <= 100000.0, has value: -2.63739e-14" LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0633337s reading init.xml | | | | | | 0.00591548s reading info.xml | | | | | | 0.000218199s [ 0.0%] pre-initialization | | | | | | 1.65974s [ 77.0%] initialization | | | | | | 3.8563e-05s [ 0.0%] steps | | | | | | 0.0569615s [ 2.6%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 0.137212s [ 6.4%] event-handling | | | | | | 0.0275401s [ 1.3%] overhead | | | | | | 0.273036s [ 12.7%] simulation | | | | | | 2.15474s [100.0%] total | | | | | events | | | | | | 145 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 2655 steps taken | | | | | | 3210 calls of functionODE | | | | | | 2195 evaluations of jacobian | | | | | | 10 error test failures | | | | | | 0 convergence test failures | | | | | | 0.136894s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully. Writing tabular output file results using HTML format. EnergyPlus Run Time=00hr 00min 1.57sec EnergyPlus Completed Successfully. Writing tabular output file results using HTML format. EnergyPlus Run Time=00hr 00min 0.80sec EnergyPlus Completed Successfully.